SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Extended search

AND is the default operator and can be omitted

Träfflista för sökning "AMNE:(MEDICAL AND HEALTH SCIENCES Medical Biotechnology) ;hsvcat:2;pers:(Lindecrantz Kaj)"

Search: AMNE:(MEDICAL AND HEALTH SCIENCES Medical Biotechnology) > Engineering and Technology > Lindecrantz Kaj

  • Result 1-10 of 22
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Gund, Anna, 1980, et al. (author)
  • Design Evaluation of a Home-Based Telecare System for Chronic Heart Failure Patients
  • 2008
  • In: Engineering in Medicine and Biology Society, 2008. EMBS 2008. 30th Annual International Conference of the IEEE. - : IEEE. - 1557-170X. - 9781424418145 ; , s. 5851-5854, s. 5851-5854
  • Conference paper (peer-reviewed)abstract
    • In order to improve the care of Chronic Heart Failure (CHF) patients, a system has been developed for monitoring symptoms and document subjective judgments on health conditions in a home environment. Since system usability is an important issue, a two step evaluation of the solution was conducted. First a ten-patient survey was conducted, which was aimed at spotting possible problem areas. The second step involved a small trial in a home setting with CHF patients. The results are promising, indicating that the system is user friendly and easy to use, and that it is suitable as a prototype for the intended use.
  •  
2.
  • Löfhede, Johan, et al. (author)
  • Classification of burst and suppression in the neonatal electroencephalogram
  • 2008
  • In: Journal of Neural Engineering. - : Institute of Physics Publishing Ltd.. - 1741-2560 .- 1741-2552. ; 5:4, s. 402-410
  • Journal article (peer-reviewed)abstract
    • Fisher's linear discriminant (FLD), a feed-forward artificial neural network (ANN) and a support vector machine (SVM) were compared with respect to their ability to distinguish bursts from suppressions in electroencephalograms (EEG) displaying a burst-suppression pattern. Five features extracted from the EEG were used as inputs. The study was based on EEG signals from six full-term infants who had suffered from perinatal asphyxia, and the methods have been trained with reference data classified by an experienced electroencephalographer. The results are summarized as the area under the curve (AUC), derived from receiver operating characteristic (ROC) curves for the three methods. Based on this, the SVM performs slightly better than the others. Testing the three methods with combinations of increasing numbers of the five features shows that the SVM handles the increasing amount of information better than the other methods.
  •  
3.
  • Wiklund, Urban, et al. (author)
  • Adaptive spatio-temporal filtering of disturbed ECGs: a multi-channel approach to heartbeat detection in smart clothing
  • 2007
  • In: Medical and Biological Engineering and Computing. - : Springer Science and Business Media LLC. - 1741-0444 .- 0140-0118. ; 45:6, s. 515-523
  • Journal article (peer-reviewed)abstract
    • Intermittent disturbances are common in ECG signals recorded with smart clothing: this is mainly because of displacement of the electrodes over the skin. We evaluated a novel adaptive method for spatio-temporal filtering for heartbeat detection in noisy multi-channel ECGs including short signal interruptions in single channels. Using multi-channel database recordings (12-channel ECGs from 10 healthy subjects), the results showed that multi-channel spatio-temporal filtering outperformed regular independent component analysis. We also recorded seven channels of ECG using a T-shirt with textile electrodes. Ten healthy subjects performed different sequences during a 10-min recording: resting, standing, flexing breast muscles, walking and pushups. Using adaptive multi-channel filtering, the sensitivity and precision was above 97% in nine subjects. Adaptive multi-channel spatio-temporal filtering can be used to detect heartbeats in ECGs with high noise levels. One application is heartbeat detection in noisy ECG recordings obtained by integrated textile electrodes in smart clothing.
  •  
4.
  • Ferreira, Javier, 1982-, et al. (author)
  • A handheld and textile-enabled bioimpedance system for ubiquitous body composition analysis. : An initial functional validation
  • 2016
  • In: IEEE journal of biomedical and health informatics. - : Institute of Electrical and Electronics Engineers (IEEE). - 2168-2194 .- 2168-2208. ; 21:5
  • Journal article (peer-reviewed)abstract
    • In recent years, many efforts have been made to promote a healthcare paradigm shift from the traditional reactive hospital-centered healthcare approach towards a proactive, patient-oriented and self-managed approach that could improve service quality and help reduce costs while contributing to sustainability. Managing and caring for patients with chronic diseases accounts over 75% of healthcare costs in developed countries. One of the most resource demanding diseases is chronic kidney disease (CKD), which often leads to a gradual and irreparable loss of renal function, with up to 12% of the population showing signs of different stages of this disease. Peritoneal dialysis and home haemodialysis are life-saving home-based renal replacement treatments that, compared to conventional in-center hemodialysis, provide similar long-term patient survival, less restrictions of life-style, such as a more flexible diet, and better flexibility in terms of treatment options and locations. Bioimpedance has been largely used clinically for decades in nutrition for assessing body fluid distributions. Moreover, bioimpedance methods are used to assess the overhydratation state of CKD patients, allowing clinicians to estimate the amount of fluid that should be removed by ultrafiltration. In this work, the initial validation of a handheld bioimpedance system for the assessment of body fluid status that could be used to assist the patient in home-based CKD treatments is presented. The body fluid monitoring system comprises a custom-made handheld tetrapolar bioimpedance spectrometer and a textile-based electrode garment for total body fluid assessment. The system performance was evaluated against the same measurements acquired using a commercial bioimpedance spectrometer for medical use on several voluntary subjects. The analysis of the measurement results and the comparison of the fluid estimations indicated that both devices are equivalent from a measurement performance perspective, allowing for its use on ubiquitous e-healthcare dialysis solutions.
  •  
5.
  • Buendia, Ruben, 1982, et al. (author)
  • Estimation of body fluids with bioimpedance spectroscopy: state of the art methods and proposal of novel methods
  • 2015
  • In: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 36:10
  • Journal article (peer-reviewed)abstract
    • Determination of body fluids is a useful common practice in determination of disease mechanisms and treatments. Bioimpedance spectroscopy (BIS) methods are non-invasive, inexpensive and rapid alternatives to reference methods such as tracer dilution. However, they are indirect and their robustness and validity are unclear. In this article, state of the art methods are reviewed, their drawbacks identified and new methods are proposed. All methods were tested on a clinical database of patients receiving growth hormone replacement therapy. Results indicated that most BIS methods are similarly accurate (e.g. < 0.5 +/- 3.0% mean percentage difference for total body water) for estimation of body fluids. A new model for calculation is proposed that performs equally well for all fluid compartments (total body water, extra-and intracellular water). It is suggested that the main source of error in extracellular water estimation is due to anisotropy, in total body water estimation to the uncertainty associated with intracellular resistivity and in determination of intracellular water a combination of both.
  •  
6.
  • Löfhede, Johan, et al. (author)
  • Comparing a Supervised and an Unsupervised Classification Method for Burst Detection in Neonatal EEG
  • 2008
  • In: Proceedings of Engineering in Medicine and Biology Society, EMBS 2008. 30th Annual International Conference of the IEEE, 20-24 August, 2008. - : IEEE. - 1557-170X. - 9781424418145 ; , s. 3836-3839
  • Conference paper (peer-reviewed)abstract
    • Hidden Markov Models (HMM) and Support Vector Machines (SVM) using unsupervised and supervised training, respectively, were compared with respect to their ability to correctly classify burst and suppression in neonatal EEG. Each classifier was fed five feature signals extracted from EEG signals from six full term infants who had suffered from perinatal asphyxia. Visual inspection of the EEG by an experienced electroencephalographer was used as the gold standard when training the SVM, and for evaluating the performance of both methods. The results are presented as receiver operating characteristic (ROC) curves and quantified by the area under the curve (AUC). Our study show that the SVM and the HMM exhibit similar performance, despite their fundamental differences.
  •  
7.
  •  
8.
  • Marquez, Juan Carlos (author)
  • On the Feasibility of Using Textile Electrodes for Electrical Bioimpedance Measurements
  • 2011
  • Licentiate thesis (other academic/artistic)abstract
    • The application of textile electrodes has been widely studied for biopotential recordings, especially for monitoring cardiac activity. Commercially available applications, such as the Adistar T-shirt and the Numetrex Cardioshirt, have shown good performance for heart rate monitoring and are available worldwide. Textile technology can also be used for electrical bioimpedance (EBI) spectroscopy measurements in home and personalized health monitoring applications, however solid basic research about the measurement performance of the electrodes must be performed prior to the development of any textile-enabled EBI application. This research work studies the performance of EBI spectroscopy measurements when performed with textile electrodes. An analysis using an electrical circuit equivalent model and experimental data obtained with the Impedimed spectrometer SFB7 was carried out. The experimental study focused on EBI spectroscopy measurements obtained with different types of textile electrodes and in different measurement scenarios. The equivalent model analysis focused on the influence of the electrode polarization impedance Zep on the EBI spectroscopy measurements in the frequency range of 3 kHz to 500 kHz. The analysis of the obtained complex EBI spectra shows that the measurements obtained with textile electrodes produce constant and reliable EBI spectra. The results also indicate the importance of the skin-electrode interface in EBI spectroscopy measurement. Textile technology, if successfully integrated, may enable the performance of EBI spectroscopy measurements in new scenarios, which would allow the generation of novel, wearable, or textile-enabled applications for home and personal health monitoring
  •  
9.
  • Marquez, Juan Carlos, et al. (author)
  • Comparison of Dry-textile Electrodes for Electrical Bioimpedance Spectroscopy Measurements.
  • 2010
  • In: Journal of Physics: Conference Series. - : Institute of Physics Publishing Ltd.. - 1742-6596.
  • Conference paper (peer-reviewed)abstract
    • Electrodes have been widely studied for biopotentials recordings, specially for monitoring the cardiac activity. Commercially available applications, such as Adistar T-shirt and Textronics Cardioshirt, have proved a good performance for heart rate monitoring and are available worldwide. Textile technology can also be used for Electrical Bioimpedance Spectroscopy measurements enabling home and personalized health monitoring applications however solid ground research about the measurement performance of the electrodes must be done prior to the development of any textile-enabled EBI application. In this work a comparison of the measurement performance of two different types of dry-textile electrodes and manufacturers has been performed against standardized RedDot 3M Ag/AgCl electrolytic electrodes. 4-Electrode, whole body, Ankle-to-Wrist EBI measurements have been taken with the Impedimed spectrometer SFB7 from healthy subjects in the frequency range of 3kHz to 500kHz. Measurements have been taken with dry electrodes at different times to study the influence of the interaction skin-electrode interface on the EBI measurements. The analysis of the obtained complex EBI spectra shows that the measurements performed with textile electrodes produce constant and reliable EBI spectra. Certain deviation can be observed at higher frequencies and the measurements obtained with Textronics and Ag/AgCl electrodes present a better resemblance. Textile technology, if successfully integrated it, may enable the performance of EBI measurements in new scenarios allowing the rising of novel wearable monitoring applications for home and personal care as well as car safety
  •  
10.
  • Löfhede, Johan, 1978, et al. (author)
  • Automatic classification of background EEG activity in healthy and sick neonates
  • 2010
  • In: Journal of Neural Engineering. - : IOP Publishing. - 1741-2560 .- 1741-2552. ; 7:1
  • Journal article (peer-reviewed)abstract
    • The overall aim of our research is to develop methods for a monitoring system to be used at neonatal intensive care units. When monitoring a baby, a range of different types of background activity needs to be considered. In this work, we have developed a scheme for automatic classification of background EEG activity in newborn babies. EEG from six full-term babies who were displaying a burst suppression pattern while suffering from the after-effects of asphyxia during birth was included along with EEG from 20 full-term healthy newborn babies. The signals from the healthy babies were divided into four behavioural states: active awake, quiet awake, active sleep and quiet sleep. By using a number of features extracted from the EEG together with Fisher’s linear discriminant classifier we have managed to achieve 100% correct classification when separating burst suppression EEG from all four healthy EEG types and 93% true positive classification when separating quiet sleep from the other types. The other three sleep stages could not be classified. When the pathological burst suppression pattern was detected, the analysis was taken one step further and the signal was segmented into burst and suppression, allowing clinically relevant parameters such as suppression length and burst suppression ratio to be calculated. The segmentation of the burst suppression EEG works well, with a probability of error around 4%.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 22
Type of publication
conference paper (12)
journal article (6)
licentiate thesis (2)
book chapter (1)
patent (1)
Type of content
peer-reviewed (15)
other academic/artistic (6)
pop. science, debate, etc. (1)
Author/Editor
Lindecrantz, Kaj, 19 ... (11)
Thordstein, Magnus (6)
Löfgren, Nils, 1969 (6)
Seoane, Fernando (5)
Kjellmer, Ingemar, 1 ... (5)
show more...
Seoane, Fernando, 19 ... (3)
Flisberg, Anders, 19 ... (3)
Marquez, Juan Carlos (3)
Löfhede, Johan (3)
Löfhede, Johan, 1978 (3)
Ekman, Inger, 1952 (2)
Sjöqvist, Bengt-Arne ... (2)
Seoane Martinez, Fer ... (2)
bragos, Ramon (2)
Gund, Anna, 1980 (2)
Flisberg, Anders (2)
Wiklund, Urban (1)
Karlsson, M (1)
Abtahi, Farhad (1)
Lindecrantz, Kaj, Pr ... (1)
Johannsson, Gudmundu ... (1)
Bosaeus, Ingvar, 195 ... (1)
Mallard, Carina, 196 ... (1)
Karlsson, Stefan (1)
Sandsjö, Leif, 1958 (1)
Degerman, Johan, 197 ... (1)
Persson, Mikael, 195 ... (1)
Ellegård, Lars, 1958 (1)
Gil-Pita, R (1)
Berglin, Lena (1)
Buendia, Ruben, 1982 (1)
Ward, L. C. (1)
Seoane Martinéz, Fer ... (1)
Dean, Justin M (1)
Ferreira Gonzalez, J ... (1)
Ferreira Gonzalez, J ... (1)
Seoane, Fernando, Do ... (1)
Jiménez Leube, Javie ... (1)
Ferreira, Javier, 19 ... (1)
Pau de la Cruz, Ivan (1)
Östlund, Nils (1)
Staaf, Eva Lina, 198 ... (1)
Thornesköld, Niklas, ... (1)
Silberberg, Ants, 19 ... (1)
Lu, Mai, 1968 (1)
Rosa-Zurera, Manuel (1)
Kjellmer, Ingmar (1)
Flisberg, I. (1)
Välimaki, Elina (1)
show less...
University
University of Borås (20)
Royal Institute of Technology (14)
Chalmers University of Technology (14)
University of Gothenburg (7)
Karolinska Institutet (4)
Umeå University (1)
Language
English (22)
Research subject (UKÄ/SCB)
Medical and Health Sciences (22)
Social Sciences (3)
Natural sciences (1)

Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view