SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "AMNE:(MEDICIN OCH HÄLSOVETENSKAP Klinisk medicin Radiologi och bildbehandling) ;pers:(Alm Carlsson Gudrun)"

Sökning: AMNE:(MEDICIN OCH HÄLSOVETENSKAP Klinisk medicin Radiologi och bildbehandling) > Alm Carlsson Gudrun

  • Resultat 1-10 av 66
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Malusek, Alexandr, 1968- (författare)
  • Calculation of scatter in cone beam CT : Steps towards a virtual tomograph
  • 2008
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Scattered photons—shortly scatter—are generated by interaction processes when photon beams interact with matter. In diagnostic radiology, they deteriorate image quality since they add an undesirable signal that lowers the contrast in projection radiography and causes cupping and streak artefacts in computed tomography (CT). Scatter is one of the most detrimental factors in cone beam CT owing to irradiation geometries using wide beams. It cannot be fully eliminated, nevertheless its amount can be lowered via scatter reduction techniques (air gaps, antiscatter grids, collimators) and its effect on medical images can be suppressed via scatter correction algorithms.Aim: Develop a tool—a virtual tomograph—that simulates projections and performs image reconstructions similarly to a real CT scanner. Use this tool to evaluate the effect of scatter on projections and reconstructed images in cone beam CT. Propose improvements in CT scanner design and image reconstruction algorithms.Methods: A software toolkit (CTmod) based on the application development framework ROOT was written to simulate primary and scatter projections using analytic and Monte Carlo methods, respectively. It was used to calculate the amount of scatter in cone beam CT for anthropomorphic voxel phantoms and water cylinders. Configurations with and without bowtie filters, antiscatter grids, and beam hardening corrections were investigated. Filtered back-projection was used to reconstruct images. Automatic threshold segmentation of volumetric CT data of anthropomorphic phantoms with known tissue compositions was tested to evaluate its usability in an iterative image reconstruction algorithm capable of performing scatter correction.Results: It was found that computer speed was the limiting factor for the deployment of this method in clinical CT scanners. It took several hours to calculate a single projection depending on the complexity of the geometry, number of simulated detector elements, and statistical precision. Data calculated using the CTmod code confirmed the already known facts that the amount of scatter is almost linearly proportional to the beam width, the scatter-to-primary ratio (SPR) can be larger than 1 for body-size objects, and bowtie filters can decrease the SPR in certain regions of projections. Ideal antiscatter grids significantly lowered the amount of scatter. The beneficial effect of classical antiscatter grids in cone beam CT with flat panel imagers was not confirmed by other researchers nevertheless new grid designs are still being tested. A simple formula estimating the effect of scatter on the quality of reconstructed images was suggested and tested.Conclusions: It was shown that computer simulations could calculate the amount of scatter in diagnostic radiology. The Monte Carlo method was too slow for a routine use in contemporary clinical practice nevertheless it could be used to optimize CT scanner design and, with some enhancements, it could become a part of an image reconstruction algorithm that performs scatter correction.
  •  
2.
  • Norberg, Pernilla, et al. (författare)
  • Does quantitative lung SPECT detect lung abnormalities earlier than lung function tests? : Results of a pilot study
  • 2014
  • Ingår i: EJNMMI Research. - : Springer Berlin/Heidelberg. - 2191-219X. ; 4:39, s. 1-12
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Heterogeneous ventilation in lungs of allergic individuals, cigarette smokers, asthmatics and chronic obstructive pulmonary disease (COPD) patients has been demonstrated using imaging modalities such as PET, MR and SPECT. These individuals suffer from narrow and/or closed airways to various extents. By calculating regional heterogeneity in lung ventilation SPECT images as the coefficient of variation (CV) in small elements of the lung, heterogeneity maps and CV-frequency curves can be generated and used to quantitatively measure heterogeneity. This work explores the potential to use such measurements to detect mild ventilation heterogeneities in lung healthy subjects.Method: Fourteen healthy subjects without documented lung disease or respiratory symptoms, and two patients with documented airway disease, inhaled on average approximately 90 MBq 99mTc-Technegas immediately prior to the 20 min SPECT acquisition. Variation in activity uptake between subjects was compensated for in resulting CV values. The area under the compensated CV frequency curve (AUC), for CV values greater than a threshold value CVT, AUC(CV> CVT), was used as the measure of ventilation heterogeneity.Results: Patients with lung function abnormalities, according to lung function tests, generated higher AUC(CV>20%) values compared to healthy subjects (p=0.006). Strong linear correlations with the AUC(CV>20%) values were found for age (p=0.006) and height (p=0.001). These demonstrated that ventilation heterogeneities increased with age and that they depend on lung size. Strong linear correlations were found for the lung function value related to indices of airway closure/air trapping, RV/TLC (p=0.009), and DLCOc (p=0.009), a value partly related to supposed ventilation/perfusion mismatch. These findings support the association between conventional lung function tests and the AUC(CV>20%) value.Conclusions: Among the healthy subjects there is a group with increased AUC(CV>20%) values, but with normal lung function tests, which implies that it might be possible to differentiate ventilation heterogeneities earlier in a disease process than by lung function tests.
  •  
3.
  • Sandborg, Michael, 1961-, et al. (författare)
  • Demonstration of correlation between physical and clinical image quality measures in chest and lumbar spine imaging.
  • 2000
  • Ingår i: Digest of papers of the 2000 world congress on medical physics. CD-Rom Chicago July 23-28,2000. - : IEEE. - 0780364651 ; , s. 3078-3081 vol.4
  • Konferensbidrag (refereegranskat)abstract
    • Clinical and physical assessments of image quality are compared and the correlation between the two derived. Clinical assessment has been made by a group of expert radiologists who evaluated the fulfillment of the European Image Criteria for chest and lumbar spine radiography; yielding the so-called Image Criteria Score, ICS. Physical measures of image quality were calculated using a Monte Carlo model of the complete imaging system. This model includes a voxelised male anatomy and calculates contrast and signal-to-noise ratio of various anatomical details and a measure of useful dynamic range. Correlations between the ICS and the physical image quality measures were sought. Four lumbar spine and 16 chest imaging systems were evaluated and simulated with the model. The most useful physical quantities for chest radiography were the dynamic range and contrast of blood vessels in the retro-cardiac area. In lumbar spine, it was the signal-to-noise ratio of trabecular structures. The significant correlation is encouraging and shows that clinical image quality can be predicted provided the imaging conditions are well known and that relevant measures of physical image quality are used to assess the quality of the image
  •  
4.
  • Sandborg, Michael, 1961-, et al. (författare)
  • Demonstration of correlations between clinical and physical image quality measures in chest and lumbar spine screen-film radiography
  • 2001
  • Ingår i: British Journal of Radiology. - : British Institute of Radiology. - 0007-1285 .- 1748-880X. ; 74:882, s. 520-528
  • Tidskriftsartikel (refereegranskat)abstract
    • The ability to predict clinical image quality from physical measures is useful for optimization in diagnostic radiology. In this work, clinical and physical assessments of image quality are compared and correlations between the two are derived. Clinical assessment has been made by a group of expert radiologists who evaluated fulfilment of the European image criteria for chest and lumbar spine radiography using two scoring methods: image criteria score (ICS) and visual grading analysis score (VGAS). Physical image quality measures were calculated using a Monte Carlo simulation model of the complete imaging system. This model includes a voxelized male anatomy and was used to calculate contrast and signal-to-noise ratio of various important anatomical details and measures of dynamic range. Correlations between the physical image quality measures on the one hand and the ICS and VGAS on the other were sought. 16 chest and 4 lumbar spine imaging system configurations were compared in frontal projection. A statistically significant correlation with clinical image quality was found in chest posteroanterior radiography for the contrast of blood vessels in the retrocardiac area and a measure of useful dynamic range. In lumbar spine anteroposterior radiography, a similar significant correlation with clinical image quality was found between the contrast and signal-to-noise ratio of the trabecular structures in the L1-L5 vertebrae. The significant correlation shows that clinical image quality can, at least in some cases, be predicted from appropriate measures of physical image quality.
  •  
5.
  •  
6.
  • Ullman, Gustaf, et al. (författare)
  • A Monte Carlo-based model for simulation of digital chest tomosynthesis
  • 2010
  • Ingår i: Radiation Protection Dosimetry. - Oxford : Oxford University Press. - 0144-8420 .- 1742-3406. ; 139:1-3, s. 159-163
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this work was to calculate synthetic digital chest tomosynthesis projections using a computer simulation model based on the Monte Carlo method. An anthropomorphic chest phantom was scanned in a computed tomography scanner, segmented and included in the computer model to allow for simulation of realistic high-resolution X-ray images. The input parameters to the model were adapted to correspond to the VolumeRAD chest tomosynthesis system from GE Healthcare. Sixty tomosynthesis projections were calculated with projection angles ranging from +15 to −15°. The images from primary photons were calculated using an analytical model of the anti-scatter grid and a pre-calculated detector response function. The contributions from scattered photons were calculated using an in-house Monte Carlo-based model employing a number of variance reduction techniques such as the collision density estimator. Tomographic section images were reconstructed by transferring the simulated projections into the VolumeRAD system. The reconstruction was performed for three types of images using: (i) noise-free primary projections, (ii) primary projections including contributions from scattered photons and (iii) projections as in (ii) with added correlated noise. The simulated section images were compared with corresponding section images from projections taken with the real, anthropomorphic phantom from which the digital voxel phantom was originally created. The present article describes a work in progress aiming towards developing a model intended for optimisation of chest tomosynthesis, allowing for simulation of both existing and future chest tomosynthesis systems.
  •  
7.
  • Adolfsson, Emelie, et al. (författare)
  • A system for remote dosimetry audit of 3D-CRT, IMRT and VMAT based on lithium formate dosimetry
  • 2014
  • Ingår i: Radiotherapy and Oncology. - : Elsevier. - 0167-8140 .- 1879-0887. ; 113:2, s. 279-282
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this work was to develop and test a remote end-to-end audit system using lithium formate EPR dosimeters. Four clinics were included in a pilot study, absorbed doses determined in the PTV agreed with TPS calculated doses within ±5% for 3D-CRT and ±7% (k=1) for IMRT/VMAT dose plans.
  •  
8.
  • Adolfsson, Emelie, 1985- (författare)
  • Lithium formate EPR dosimetry for accurate measurements of absorbed dose in radiotherapy
  • 2014
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Lithium formate has shown to be a material with properties suitable for electron paramagnetic resonance (EPR) dosimetry, among them up to 7 times higher sensitivity compared to alanine, which is a well-established EPR detector material for dose determinations in radiotherapy.The aim of this thesis was to further investigate the properties of lithium formate and develop the dosimetry system towards applications in radiotherapy. The intrinsic efficiency for energies of relevance to brachytherapy and the signal stability were investigated. The dosimetry system was expanded to include a smaller dosimeter model, suitable for measurements in dose gradient regions. An individual sensitivity correction method was applied to the smaller dosimeters to be able to perform dose determinations with the same precision as for the larger ones. EPR dosimetry in general is time consuming and effort was spent to optimize the signal readout procedure regarding measurement time and measurement precision.The system was applied in two clinical applications chosen for their high demands on the dosimetry system: 1) a dosimetry audit for external photon beam therapy and 2) dose verification measurements around a low energy HDR brachytherapy source.The conclusions drawn from this thesis were: dose determinations can be performed with a standard uncertainty of 1.8-2.5% using both the original size dosimeters and the new developed smaller ones. The dosimetry system is robust and useful for applications when high measurement precision and accuracy is prioritized. It is a good candidate for dosimetry audits, both in external beam therapy and brachytherapy.
  •  
9.
  • Adolfsson, Emelie, et al. (författare)
  • Measurement of absorbed dose to water around an electronic brachytherapy source : Comparison of two dosimetry systems: lithium formate EPR dosimeters and radiochromic EBT2 film
  • 2015
  • Ingår i: Physics in Medicine and Biology. - : Institute of Physics Publishing (IOPP). - 0031-9155 .- 1361-6560. ; 60:9, s. 3869-3882
  • Tidskriftsartikel (refereegranskat)abstract
    • Interest in high dose rate (HDR) electronic brachytherapy operating at 50 kV is increasing. For quality assurance it is important to identify dosimetry systems that can measure the absorbed doses in absolute terms which is difficult in this energy region. In this work a comparison is made between two dosimetry systems, EPR lithium formate dosimeters and radiochromic EBT2 film.Both types of dosimeters were irradiated simultaneously in a PMMA phantom using the Axxent EBS. Absorbed dose to water was determined at distances of 10 mm, 30 mm and 50 mm from the EBS. Results were traceable to different primary standards as regards to absorbed dose to water (EPR) and air kerma (EBT2). Monte Carlo simulations were used in absolute terms as a third estimate of absorbed dose to water.Agreement within the estimated expanded (k = 2) uncertainties (5% (EPR), 7% (EBT2)) was found between the results at 30 mm and 50 mm from the x-ray source. The same result was obtained in 4 repetitions of irradiation, indicating high precision in the measurements with both systems. At all distances, agreement between EPR and Monte Carlo simulations was shown as was also the case for the film measurements at 30mm and 50mm. At 10mm the geometry for the film measurements caused too large uncertainty in measured values depending on the exact position (within sub-mm distances) of the EBS and the 10 mm film results were exculded from comparison.This work has demonstrated good performance of the lithium formate EPR dosimetry system in accordance with earlier experiments at higher photon energies (192Ir HDR brachytherapy). It was also highlighted that there might be issues regarding the energy dependence and intrinsic efficiency of the EBT2 film that need to be considered for measurements using low energy sources.
  •  
10.
  • Adolfsson, Emelie, et al. (författare)
  • Optimisation of an EPR dosimetry system for robust and high precision dosimetry
  • 2014
  • Ingår i: Radiation Measurements. - : Elsevier. - 1350-4487 .- 1879-0925. ; 70, s. 21-28
  • Tidskriftsartikel (refereegranskat)abstract
    • Clinical applications of electron paramagnetic resonance (EPR) dosimetry systems demand high accuracy causing time consuming analysis. The need for high spatial resolution dose measurements in regions with steep dose gradients demands small sized dosimeters. An optimization of the analysis was therefore needed to limit the time consumption. The aim of this work was to introduce a new smaller lithium formate dosimeter model (diameter reduced from standard diameter 4.5 mm to 3 mm and height from 4.8 mm to 3 mm). To compensate for reduced homogeneity in a batch of the smaller dosimeters, a method for individual sensitivity correction suitable for EPR dosimetry was tested. Sensitivity and repeatability was also tested for a standard EPR resonator and a super high Q (SHQE) one. The aim was also to optimize the performance of the dosimetry system for better efficiency regarding measurement time and precision. A systematic investigation of the relationship between measurement uncertainty and number of readouts per dosimeter was performed. The conclusions drawn from this work were that it is possible to decrease the dosimeter size with maintained measurement precision by using the SHQE resonator and introducing individual calibration factors for dosimeter batches. It was also shown that it is possible reduce the number of readouts per dosimeter without significantly decreasing the accuracy in measurements.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 66
Typ av publikation
rapport (32)
tidskriftsartikel (21)
konferensbidrag (7)
doktorsavhandling (5)
bokkapitel (1)
Typ av innehåll
övrigt vetenskapligt/konstnärligt (42)
refereegranskat (24)
Författare/redaktör
Sandborg, Michael (24)
Sandborg, Michael, 1 ... (11)
Alm Carlsson, Gudrun ... (9)
Båth, Magnus, 1974 (8)
Mattsson, Sören (6)
visa fler...
Carlsson Tedgren, Ås ... (6)
Lund, Eva (4)
Besjakov, Jack (4)
Helmrot, Ebba (4)
Persliden, Jan (4)
Adolfsson, Emelie (3)
Gustafsson, Håkan (3)
Medin, Joakim (3)
Olsson, Sara (2)
Carlsson Tedgren, Ås ... (2)
Ljungberg, Michael (2)
Eriksson, Fredrik (2)
Håkansson, M. (2)
Carlsson, Carl A. (2)
Almén, A (2)
Larsson, Erik (1)
Pettersson, Håkan (1)
Börjesson, S (1)
Adolfsson, Emelie, 1 ... (1)
Carlsson Tedgren, Ås ... (1)
Lund, Eva, Professor ... (1)
Gustafsson, Håkan, D ... (1)
Alm Carlsson, Gudrun ... (1)
Sharpe, Peter, Dr. (1)
White, Shane (1)
Landry, Guillaume (1)
Verhaegen, Frank (1)
Reniers, Brigitte (1)
Tylén, Ulf, 1938 (1)
Persson, Lennart (1)
Olsson, Anna (1)
Larsson, Peter (1)
Kheddache, S (1)
Gustafsson, Johan (1)
Warfvinge, Carl Fred ... (1)
Ekberg, Stefan (1)
Lindström, Jan (1)
Matscheko, Georg (1)
Nilsson, Håkan (1)
Stenström, Mats (1)
Almén, Anja, 1964 (1)
Almén, Anja (1)
Mattsson, S. (1)
Medin, J. (1)
visa färre...
Lärosäte
Linköpings universitet (61)
Göteborgs universitet (11)
Lunds universitet (7)
Karolinska Institutet (5)
Språk
Engelska (51)
Svenska (15)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (66)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy