SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "AMNE:(MEDICIN OCH HÄLSOVETENSKAP Klinisk medicin Radiologi och bildbehandling) ;pers:(Valentin Lil)"

Sökning: AMNE:(MEDICIN OCH HÄLSOVETENSKAP Klinisk medicin Radiologi och bildbehandling) > Valentin Lil

  • Resultat 1-10 av 113
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kuusela, Pihla, et al. (författare)
  • Second trimester cervical length measurements with transvaginal ultrasound : a prospective observational agreement and reliability study
  • 2020
  • Ingår i: Acta Obstetricia et Gynecologica Scandinavica. - : John Wiley & Sons. - 0001-6349 .- 1600-0412. ; 99:11, s. 1476-1485
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION: Universal screening for preterm delivery by adding transvaginal ultrasound measurement of cervical length to routine second trimester ultrasound has been proposed. The aim is to estimate inter- and intra-observer agreement and reliability of second trimester transvaginal ultrasound measurements of cervical length performed by specially trained midwife sonographers.MATERIAL AND METHODS: This is a prospective reliability and agreement study performed in seven Swedish ultrasound centers. In total, 18 midwife sonographers specially trained to perform ultrasound measurements of cervical length and 286 women in the second trimester were included. In each center two midwife sonographers measured cervical length a few minutes apart in the same woman, the number of women examined per examiner pair varying between 24 and 30 (LIVE study). Sixteen midwife sonographers measured cervical length twice ≥2 months apart on 93 video-clips (CLIPS study). The main outcome measures were mean difference, limits of agreement, intra-class correlation coefficient, intra-individual standard deviation, repeatability, Cohen´s kappa, and Fleiss kappa.RESULTS: The limits of agreement and intra-class correlation coefficient of the best examiner pair in the LIVE study were -4.06 to 4.72 mm and 0.91, those of the poorest were -11.11 to 11.39 mm and 0.31. In the CLIPS study, median (range) intra-individual standard deviation was 2.14 mm (1.40 to 3.46), repeatability 5.93 mm (3.88 to 9.58), intra-class correlation coefficient 0.84 (0.66 to 0.94). Median (range) inter-observer agreement for cervical length ≤25 mm in the CLIPS study was 94.6% (84.9% to 98.9%) and Cohen´s kappa 0.56 (0.12 to 0.92), median (range) intra-observer agreement was 95.2% (87.1% to 98.9%) and Cohen´s kappa 0.68 (0.27 to 0.93).CONCLUSIONS: Agreement and reliability of cervical length measurements differed substantially between examiner pairs and examiners. If cervical length measurements are used to guide management there is potential for both over- and under-treatment. Uniform training and rigorous supervision and quality control are advised.
  •  
2.
  •  
3.
  •  
4.
  • Ameye, L., et al. (författare)
  • A scoring system to differentiate malignant from benign masses in specific ultrasound-based subgroups of adnexal tumors
  • 2009
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 33:1, s. 92-101
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective To investigate if the prediction of malignant adnexal masses can be improved by considering different ultrasound-based subgroups of tumors and constructing a scoring system for each subgroup instead of using a risk estimation model applicable to all tumors. Methods We used a multicenter database of 1573 patients with at least one persistent adnexal mass. The masses were categorized into four subgroups based on their ultrasound appearance: ( 1) unilocular cyst; ( 2) multilocular cyst; ( 3) presence of a solid component but no papillation; and ( 4) presence of papillation. For each of the four subgroups a scoring system to predict malignancy was developed in a development set consisting of 754 patients in total ( respective numbers of patients: ( 1) 228; ( 2) 143; ( 3) 183; and ( 4) 200). The subgroup scoring system was then tested in 312 patients and prospectively validated in 507 patients. The sensitivity and specificity, with regard to the prediction of malignancy, of the scoring system were compared with that of the subjective evaluation of ultrasound images by an experienced examiner ( pattern recognition) and with that of a published logistic regression (LR) model for the calculation of risk of malignancy in adnexal masses. The gold standard was the pathological classification of the mass as benign or malignant ( borderline, primary invasive, or metastatic). Results In the prospective validation set, the sensitivity of pattern recognition, the LR model and the subgroup scoring system was 90% (129/143), 95% (136/143) and 88% (126/143), respectively, and the specificity was 93% (338/364), 74% (270/364) and 90% (329/364), respectively. Conclusions In the hands of experienced ultrasound examiners, the subgroup scoring system for diagnosing malignancy has a performance that is similar to that of pattern recognition, the latter method being the best diagnostic method currently available. The scoring system is less sensitive but more specific than the LR model. Copyright (C) 2008 ISUOG. Published by John Wiley & Sons, Ltd.
  •  
5.
  • Ameye, L., et al. (författare)
  • Clinically oriented three-step strategy for assessment of adnexal pathology
  • 2012
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 40:5, s. 582-591
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective To determine the diagnostic performance of ultrasound-based simple rules, risk of malignancy index (RMI), two logistic regression models (LR1 and LR2) and real-time subjective assessment by experienced ultrasound examiners following the exclusion of masses likely to be judged as easy and 'instant' to diagnose by an ultrasound examiner, and to develop a new strategy for the assessment of adnexal pathology based on this. Methods 3511 patients with at least one persistent adnexal mass preoperatively underwent transvaginal ultrasonography to assess tumor morphology and vascularity. They were included in two consecutive prospective studies by the International Ovarian Tumor Analysis (IOTA) group: Phase 1 (1999-2005), development of the simple rules and logistic regression models LR1 and LR2, and Phase 2, a validation study (2005-2007). Results Almost half of the cases (43%) were identified as 'instant' to diagnose on the basis of descriptors applied to the database. To assess diagnostic performance in the more difficult 'non-instant' masses, we used only Phase 2 data (n = 1036). The sensitivity of LR2 was 88%, of RMI it was 41% and of subjective assessment it was 87%. The specificity of LR2 was 67%, of RMI it was 90% and of subjective assessment it was 86%. The simple rules yielded a conclusive result in almost 2/3 of the masses, where they resulted in sensitivity and specificity similar to those of real-time subjective assessment by experienced ultrasound examiners: sensitivity 89 vs 89% (P = 0.76), specificity 91 vs 91% (P = 0.65). When a three-step strategy was appliedwith easy 'instant' diagnoses as Step 1, simple rules where conclusive as Step 2 and subjective assessment by an experienced ultrasound examiner in the remaining masses as Step 3, we obtained a sensitivity of 92% and specificity of 92% compared with sensitivity 90% (P = 0.03) and specificity 93% (P = 0.44) when using real-time subjective assessment by experts in all tumors. Conclusion A diagnostic strategy using simple descriptors and ultrasound rules when applied to the variables contained in the IOTA database obtains results that are at least as good as those obtained by subjective assessment of a mass by an expert. Copyright. (C) 2012 ISUOG. Published by John Wiley & Sons, Ltd.
  •  
6.
  • Andersson, Johanna K., et al. (författare)
  • Inter-Rater Agreement for Diagnosing Adenomyosis Using Magnetic Resonance Imaging and Transvaginal Ultrasonography
  • 2023
  • Ingår i: Diagnostics. - 2075-4418. ; 13:13
  • Tidskriftsartikel (refereegranskat)abstract
    • Our aim was to compare the inter-rater agreement about transvaginal ultrasonography (TVS) with magnetic resonance imaging (MRI) with regard to diagnosing adenomyosis and for assessing various predefined imaging features of adenomyosis, in the same set of women. The study cohort included 51 women, prospectively, consecutively recruited based on a clinical suspicion of adenomyosis. MRIs and TVS videoclips and 3D volumes were retrospectively assessed by four experienced radiologists and five experienced sonographers, respectively. Each rater subjectively evaluated the presence or absence of adenomyosis, as well as imaging features suggestive of adenomyosis. Fleiss kappa (κ) was used to reflect inter-rater agreement for categorical data, and the intraclass correlation coefficient (ICC) was used to reflect the reliability of quantitative data. Agreement between raters for diagnosing adenomyosis was higher for TVS than for MRI (κ = 0.42 vs. 0.28). MRI had a higher inter-rater agreement in assessing wall asymmetry, irregular junctional zone (JZ), and the presence of myometrial cysts, while TVU had a better agreement for assessing globular shape. MRI showed a moderate to good reliability for measuring the JZ (ICC = 0.57–0.82). For TVS, the JZ was unmeasurable in >50% of cases, and the remaining cases had low reliability (ICC = −0.31–0.08). We found that inter-rater agreement for diagnosing adenomyosis was higher for TVS than for MRI, despite the fact that MRI showed a higher inter-rater agreement in most specific features. Measurements of JZ in the coronal plane with 3D TVS were unreliable and thus unlikely to be useful for diagnosing adenomyosis.
  •  
7.
  •  
8.
  • Bergelin, I., et al. (författare)
  • Patterns of normal change in cervical length and width during pregnancy in nulliparous women: a prospective, longitudinal ultrasound study
  • 2001
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 18:3, s. 217-222
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: To determine what constitutes normal changes in the uterine cervix visible at transvaginal ultrasound examination from 24 gestational weeks until delivery in nulliparous women delivering at term. DESIGN: Cervical length and width were measured using transvaginal ultrasound, and the inner cervical os was assessed as being closed or open every 2 weeks from gestational week 24 until delivery in 19 healthy nulliparae delivering at term. RESULTS: In all but one woman cervical length decreased, and in all but one woman cervical width increased, with advancing gestation. Three patterns of change in cervical length were observed: a continuous decrease ( n = 10), an accelerated shortening rate after approximately 30 gestational weeks ( n = 5), or a sudden drop in length between the last two examinations ( n = 3). The median rate of decrease in cervical length was 1 (range, 0.6-1.9) mm/week for women with continuous shortening of the cervix. For women with accelerated shortening the corresponding figure was 2.2 (range, 1.8-2.7) mm/week after the start of accelerated shortening. Two patterns of increase in cervical width (cervical broadening) were noted: a continuous increase ( n = 12), or an accelerated broadening rate from around 32 weeks ( n = 6). The median rate of increase in cervical width was 0.8 (range, 0.3-2.0) mm/week for women with continuous broadening of the cervix. For women with accelerated broadening rate the corresponding figure was 1.7 (range, 1.0-6.4) mm/week after the start of increased broadening rate. Opening of the internal cervical os was observed at least once in eight of the 19 women (42%) and was first observed at 30 gestational weeks. Dynamic changes (i.e. opening and closing of the inner cervical os during examination) were seen in six women (32%) and were first detected at 31 gestational weeks. CONCLUSIONS: There are different patterns of normal change in cervical length and width during pregnancy in nulliparous women. This must be taken into account if repeated ultrasound examinations of the cervix during pregnancy are used to identify nulliparae at increased risk of preterm delivery.
  •  
9.
  • Chiappa, V., et al. (författare)
  • Agreement of two-dimensional and three-dimensional transvaginal ultrasound with magnetic resonance imaging in assessment of parametrial infiltration in cervical cancer
  • 2015
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 45:4, s. 459-469
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives To compare two-dimensional (2D) and three-dimensional (3D) transvaginal ultrasound with magnetic resonance imaging (MRI) as the gold standard in assessment of parametrial infiltration of cervical cancer and to determine if all parts of the cervix are equally assessable with ultrasound. Methods Patients with macroscopically evident and histologically confirmed cervical cancer were staged using International Federation of Gynecology and Obstetrics (FIGO) criteria and underwent MRI and 2D and 3D ultrasound examination before treatment. When assessing parametrial infiltration with 3D ultrasound and MRI, the cervix was (virtually) divided into three cylinders (cranial, middle and caudal) of equal size and each cylinder was then divided into six sectors in a clockwise manner following a consensus between radiologists and ultrasound examiners. The presence and the extent of parametrial invasion were recorded for each sector. Results of 2D ultrasound, 3D ultrasound and MRI were compared and reported in terms of percentage agreement and kappa value. Results A total of 29 consecutive patients were included in the study. The percentage agreement between 2D ultrasound and MRI in assessing parametrial infiltration (yes or no) was 76% (kappa, 0.459) and that between 3D ultrasound and MRI was 79% (kappa, 0.508). The results of 2D ultrasound showed the following agreement with those of MRI: 90% for the ventral parametrium (kappa, 0.720), 72% for the right lateral parametrium kappa, 0.494), 69% for the left lateral parametrium (kappa, 0.412) and 58.5% for the dorsal parametrium (kappa, 0.017). The results of 3D ultrasound showed the following agreement with those of MRI: 62.5% for the ventral parametrium (kappa, 0.176), 81% for the right lateral parametrium (kappa, 0.595), 70% for the left lateral parametrium (kappa, 0.326) and 52% for the dorsal parametrium (kappa, 0.132). The best agreement between 3D ultrasound and MRI was for the middle cervical cylinder (76%; kappa, 0.438) and the poorest agreement was for the caudal cylinder (42%; kappa, 0.125). Conclusion The results of 2D and 3D ultrasound showed similar moderate agreement with MRI; 2D and 3D ultrasound examinations are less costly and more readily available than MRI and should be considered in the preoperative work-up for cervical cancer. Copyright (C) 2014 ISUOG. Published by John Wiley & Sons Ltd.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 113

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy