1.
  •  
2.
  • Agmo Hernández, Víctor, et al. (författare)
  • Enhanced interpretation of adsorption data generated by liquid chromatography and by modern biosensors
  • 2013
  • Ingår i: Journal of Chromatography A. - : Elsevier BV. - 0021-9673 .- 1873-3778. ; 1317, s. 22-31
  • Tidskriftsartikel (refereegranskat)abstract
    • In this study we demonstrate the importance of proper data processing in adsorption isotherm estimations. This was done by investigating and reprocessing data from five cases on two closely related platforms: liquid chromatography (LC) and biosensors. The previously acquired adsorption data were reevaluated and reprocessed using a three-step numerical procedure: (i) preprocessing of adsorption data, (ii) adsorption data analysis and (iii) final rival model fit. For each case, we will discuss what we really measure and what additional information can be obtained by numerical processing of the data. These cases clearly demonstrate that numerical processing of LC and biosensor data can be used to gain deeper understanding of molecular interactions with adsorption media. This is important because adsorption data, especially from biosensors, is often processed using old and simplified methods. (C) 2013 Elsevier B.V. All rights reserved.
  •  
3.
  • Bagge, Joakim, et al. (författare)
  • Impact of stationary-phase pore size on chromatographic performance using oligonucleotide separation as a model
  • 2020
  • Ingår i: Journal of Chromatography A. - : Elsevier. - 0021-9673 .- 1873-3778. ; 1634, s. 1-10
  • Tidskriftsartikel (refereegranskat)abstract
    • A combined experimental and theoretical study was performed to understand how the pore size of packing materials with pores 60-300 angstrom in size affects the separation of 5-50-mer oligonucleotides. For this purpose, we developed a model in which the solutes were described as thin rods to estimate the accessible surface area of the solute as a function of the pore size and solute size. First, an analytical investigation was conducted in which we found that the selectivity increased by a factor of 2.5 when separating 5- and 15-mer oligonucleotides using packing with 300 angstrom rather than 100 angstrom pores. We complemented the analytical investigation by theoretically demonstrating how the selectivity is dependent on the column's accessible surface area as a function of solute size. In the preparative investigation, we determined adsorption isotherms for oligonucleotides using the inverse method for separations of a 9- and a 10-mer. We found that preparative columns with a 60 angstrom-pore-size packing material provided a 10% increase in productivity as compared with a 300 A packing material, although the surface area of the 60 angstrom packing is as much as five time larger.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  • Enmark, Martin, 1984-, et al. (författare)
  • A closer study of peak distortions in supercritical fluid chromatography as generated by the injection
  • 2015
  • Ingår i: Journal of Chromatography A. - : Elsevier. - 0021-9673 .- 1873-3778. ; 1400, s. 131-139
  • Tidskriftsartikel (refereegranskat)abstract
    • Abstract In SFC the sample cannot be dissolved in the mobile phase, so it is often dissolved in pure modifier, or another liquid, sometimes resulting in serious distortions of the eluted peak profiles already at moderately high injection volumes. It is suspected the reasons for these effects are solvent strength mismatch and/or viscosity mismatch. This study presents a systematic and fundamental investigation of the origin of these peak deformations due to the injection solvent effects in SFC, using both systematic experiments and numerical modeling. The first set of experiments proved that the injection volume and the elution strength of the sample solution had a major impact of the shapes of the eluted peaks. Secondly, the sample band elution profile was numerically modeled on a theoretical basis assuming both un-retained and retained co-solvent injection plugs, respectively. These calculations quantitatively confirmed our first set of experiments but also pointed out that there is also an additional significant effect. Third, viscous fingering experiments were performed using viscosity contrast conditions imitating those encountered in SFC. These experiments clearly proved that viscous fingering effects play a significant role. A new method for determination of adsorption isotherms of solvents was also developed, called the “Retention Time Peak Method” (RTPM). The RTPM was used for fast estimation of the adsorption isotherms of the modifier and required using only two experiments.
  •  
9.
  • Enmark, Martin, et al. (författare)
  • A systematic investigation of algorithm impact in preparative chromatography with experimental verifications
  • 2011
  • Ingår i: Journal of Chromatography A. - Amsterdam : Elsevier. - 0021-9673 .- 1873-3778. ; 1218:5, s. 662-672
  • Tidskriftsartikel (refereegranskat)abstract
    • Computer-assisted optimization of chromatographic separations requires finding the numerical solution of the Equilibrium-Dispersive (ED) mass balance equation. Furthermore, the competitive adsorption isotherms needed for optimization are often estimated numerically using the inverse method that also solves the ED equations. This means that the accuracy of the estimated adsorption isotherm parameters explicitly depends on the numerical accuracy of the algorithm that is used to solve the ED equations. The fast and commonly used algorithm for this purpose, the Rouchon Finite Difference (RFD) algorithm, has often been reported not to be able to accurately solve the ED equations for all practical preparative experimental conditions, but its limitations has never been completely and systematically investigated. In this study, we thoroughly investigate three different algorithms used to solve the ED equations: the RFD algorithm, the Orthogonal Collocation on Finite Elements (OCFE) method and a Central Difference Method (CDM) algorithm, both for increased theoretical understanding and for real cases of industrial interest. We identified discrepancies between the conventional RFD algorithm and the more accurate OCFE and CDM algorithms for several conditions, such as low efficiency, increasing number of simulated components and components present at different concentrations. Given high enough efficiency, we experimentally demonstrate good prediction of experimental data of a quaternary separation problem using either algorithm, but better prediction using OCFE/CDM for a binary low efficiency separation problem or separations when the compounds have different efficiency. Our conclusion is to use the RFD algorithm with caution when such conditions are present and that the rule of thumb that the number of theoretical plates should be greater than 1000 for application of the RFD algorithm is underestimated in many cases
  •  
10.
  • Enmark, Martin, 1984-, et al. (författare)
  • Building machine-learning-based models for retention time and resolution predictions in ion pair chromatography of oligonucleotides
  • 2022
  • Ingår i: Journal of Chromatography A. - : Elsevier. - 0021-9673 .- 1873-3778. ; 1671
  • Tidskriftsartikel (refereegranskat)abstract
    • Support vector regression models are created and used to predict the retention times of oligonucleotides separated using gradient ion-pair chromatography with high accuracy. The experimental dataset consisted of fully phosphorothioated oligonucleotides. Two models were trained and validated using two pseudo orthogonal gradient modes and three gradient slopes. The results show that the spread in retention time differs between the two gradient modes, which indicated varying degree of sequence dependent separation. Peak widths from the experimental dataset were calculated and correlated with the guanine cytosine content and retention time of the sequence for each gradient slope. This data was used to predict the resolution of the n - 1 impurity among 250 0 0 0 random 12-and 16-mer sequences; showing one of the investigated gradient modes has a much higher probability of exceeding a resolution of 1.5, particularly for the 16-mer sequences. Sequences having a high guanine-cytosine content and a terminal C are more likely to not reach critical resolution. The trained SVR models can both be used to identify characteristics of different separation methods and to assist in the choice of method conditions, i.e. to optimize resolution for arbitrary sequences. The methodology presented in this study can be expected to be applicable to predict retention times of other oligonucleotide synthesis and degradation impurities if provided enough training data.
  •  