SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0021 9673 ;pers:(Wang Thanh 1979)"

Sökning: L773:0021 9673 > Wang Thanh 1979

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Geng, Dawei, 1986-, et al. (författare)
  • Gas chromatography/atmospheric pressure chemical ionization/mass spectrometry for the analysis of organochlorine pesticides and polychlorinated biphenyls in human serum
  • 2016
  • Ingår i: Journal of Chromatography A. - Amsterdam, Netherlands : Elsevier. - 0021-9673 .- 1873-3778. ; 1453, s. 88-98
  • Tidskriftsartikel (refereegranskat)abstract
    • A method using a novel atmospheric pressure chemical ionization source for coupling gas chromatography (GC/APCI) to triple quadrupole mass spectrometry (MS/MS) for the determination of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) regulated by the Stockholm Convention is presented. One microliter injection of a six-point calibration curve of native PCBs and OCPs, ranging from 0.04 to 300 pg/μL, was performed. The relative standard deviation (RSD) of the relative response factors (RRFs) was less than 15% with a coefficient of determination (r2) >0.995. Meanwhile, two calibration solutions (CS), CS 2 (0.4 pg/μL) and CS 3 (4 pg/μL) were analyzed to study the repeatability calculated for both area and RRFs. The RSD for RRF ranged from 3.1 to 16% and 3.6 to 5.5% for CS 2 and CS 3, respectively. The limits of detection (LOD) determined by peak-to-peak signal-to-noise ratio (S/N) of 3 were compared between the GC/APCI/MS/MS and a GC coupled to high resolution mass spectrometry (GC/HRMS) system. GC/APCI/MS/MS resulted in lower LOD for most of the compounds, except for PCB#74, cis-chlordane and trans-chlordane. GC/APCI/MS/MS and GC/HRMS were also compared by performing analysis on 75 human serum samples together with eight QA/QC serum samples. The comparison between GC/APCI/MS/MS system and GC/HRMS system for 16 of the targeted compounds was carried out. No statistically significant difference was discovered. Due to increased sensitivity and user friendly operation under atmospheric pressure, GC/APCI/MS/MS is a powerful alternative technique that can easily meet the specification of GC/HRMS.
  •  
2.
  • Liu, Qian, et al. (författare)
  • Evaluation of graphene as an advantageous adsorbent for solid-phase extraction with chlorophenols as model analytes
  • 2011
  • Ingår i: Journal of Chromatography A. - : Elsevier. - 0021-9673 .- 1873-3778. ; 1218:2, s. 197-204
  • Tidskriftsartikel (refereegranskat)abstract
    • Graphene, a novel class of carbon nanostructures, possesses an ultrahigh specific surface area, and thus has great potentials for the use as sorbent materials. We herein demonstrate the use of graphene as a novel adsorbent for solid-phase extraction (SPE). Eight chlorophenols (CPs) as model analytes were extracted on a graphene-packed SPE cartridge, and then eluted with alkaline methanol. The concentrations in the eluate were determined by HPLC with multi-wavelength UV detection. Under the optimized conditions, high sensitivity (detection limits 0.1-0.4 ng/mL) and good reproducibility of CPs (RSDs 2.2-7.7% for run-to-run assays) were achieved. Comparative studies showed that graphene was superior to other adsorbents including C18 silica, graphitic carbon, single- and multi-walled carbon nanotubes for the extraction of CPs. Some other advantages of graphene as SPE adsorbent, such as good compatibility with various organic solvents, good reusability and no impact of sorbent drying, have also been demonstrated. The proposed method was successfully applied to the analysis of tap and river water samples with recoveries ranging from 77.2 to 116.6%. This work not only proposes a useful method for environmental water sample pretreatment, but also reveals great potentials of graphene as an excellent sorbent material in analytical processes.
  •  
3.
  • Liu, Qian, et al. (författare)
  • Graphenized pencil lead fiber : facile preparation and application in solid-phase microextraction
  • 2014
  • Ingår i: Journal of Chromatography A. - : Elsevier. - 0021-9673 .- 1873-3778. ; 1325, s. 1-7
  • Tidskriftsartikel (refereegranskat)abstract
    • Graphenized pencil lead fiber was facilely prepared by in situ chemical exfoliation of graphite in pencil lead fiber to few-layered graphene sheets via a one-pot, one-step pressurized oxidation reaction for the first time. This new fiber was characterized and demonstrated to be a highly efficient but low-cost solid-phase microextraction (SPME) fiber. The extraction performance of the fiber was evaluated with four bisphenol analogs [bisphenol A (BPA), bisphenol S (BPS), bisphenol AF (BPAF), and tetrabromobisphenol A (TBBPA)] as model analytes in direct SPME mode. Unlike commercially available fibers, the graphenized pencil lead fiber showed an excellent chemical stability in highly saline, acidic, alkaline and organic conditions due to its coating-free configuration. The fiber also showed a very long lifespan. Furthermore, high extraction efficiency and good selectivity for the analytes with a wide polarity range could be obtained due to the exceptional properties of graphene. The detection limits (LODs) for the analytes were in the range of 1.1-25ng/L. The fiber was successfully applied in the analysis of tap water and effluent samples from a waste water treatment plant with spike recoveries ranging from 68.5 to 105.1%. Therefore, the graphenized pencil lead fiber provides a high performance, cheap, robust, and reliable tool for SPME.
  •  
4.
  • Liu, Qian, et al. (författare)
  • Hemimicelles/admicelles supported on magnetic graphene sheets for enhanced magnetic solid-phase extraction
  • 2012
  • Ingår i: Journal of Chromatography A. - : Elsevier. - 0021-9673 .- 1873-3778. ; 1257, s. 1-8
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work, superparamagnetic nanoparticle-decorated graphene (MG) sheets were synthesized and used as support for hemimicelles/admicelles for solid-phase extraction (SPE) of different compounds from environmental water samples for the first time. The MG sheets were facilely synthesized by a one-step, one-pot redox reaction between graphene oxide and Fe(II). Due to the large surface area and unique nanosheet morphology, MG served as an excellent nano-scaled support material for hemimicelles and admicelles, exhibiting higher loading capacity than conventional materials and pure Fe₃O₄ nanoparticles. The MG sheets could be negatively or positively charged depending on solution pH, allowing the extraction to be conducted in different modes. In cationic mode, cetyltrimethylammonium bromide (CTAB) was used as micelle-forming reagent, and perfluoroalkyl and polyfluoroalkyl substances (PFASs) and alkylphenols were used as model analytes. In anionic mode, sodium dodecyl sulfate (SDS) was used as micelle-forming reagent and alkyltrimethylammonium salts were selected as analytes. In both modes, the formation processes of hemimicelles/admicelles on MG sheets were studied and the extraction conditions were optimized. For PFASs, the analytical sensitivity was enhanced by 50-113-fold by the extraction, and the method detection limits (MDLs) ranged from 0.15 to 0.50 ng/L. For alkyltrimethylammonium salts, the MDLs were in the range of 1.4-8.0 ng/L. In both modes, good recoveries (56.3-93.9%) and reproducibility (run-to-run RSDs<9.3%) were obtained. The results from this work show a potential new role of graphene in analytical sample preparation.
  •  
5.
  • Ruan, Ting, et al. (författare)
  • Trace determination of airborne polyfluorinated iodine alkanes using multisorbent thermal desorption/gas chromatography/high resolution mass spectrometry
  • 2010
  • Ingår i: Journal of Chromatography A. - : Elsevier. - 0021-9673 .- 1873-3778. ; 1217:26, s. 4439-4447
  • Tidskriftsartikel (refereegranskat)abstract
    • A novel gas chromatography/high resolution mass spectrometry method coupled with multisorbent thermal desorption cartridges has been developed for the determination of volatile neutral polyfluorinated iodine alkanes (PFIs) in airborne samples. It allows, for the first time, simultaneous analysis of four mono-iodized perfluorinated alkanes, three diiodized perfluorinated alkanes and four mono-iodized polyfluorinated telomers in ambient air samples. 3.75 L air sample was passed through a sorbent tube packed with 150 mg of Tenax TA and 200mg of Carbograph 1 TD for analyte adsorption. Important factors during the analysis procedures, such as safe sampling volume, air sampling rate, analyte desorption and transfer strategies, were optimized and good thermal desorption efficiencies were obtained. The method detection limit (MDL) concentration ranged from 0.04 pg/L for 1H,1H,2H,2H-perfluorododecyl iodide to 1.2 pg/L for perfluorohexyl iodide, and instrument response of a seven-point calibration was linear in the range of 10-1000 pg. Travel spike recoveries ranged from 83% to 116%. Small variabilities of less than 36% were obtained near the MDLs and the differences between triplicates were even smaller (2.1-7.3%) at 200 pg spiked level. The method was successfully applied to analyze ambient air samples collected near a point source, and five PFIs were identified (10.8-85.0 pg/L), with none of the analytes detectable at the background site.
  •  
6.
  • Tao, Yong, et al. (författare)
  • Hollow fiber supported ionic liquid membrane microextraction for determination of sulfonamides in environmental water samples by high-performance liquid chromatography
  • 2009
  • Ingår i: Journal of Chromatography A. - : Elsevier. - 0021-9673 .- 1873-3778. ; 1216:35, s. 6259-6266
  • Tidskriftsartikel (refereegranskat)abstract
    • By using ionic liquid as membrane liquid and tri-n-octylphosphine oxide (TOPO) as additive, hollow fiber supported liquid phase microextraction (HF-LPME) was developed for the determination of five sulfonamides in environmental water samples by high-performance liquid chromatography with ultraviolet detection The extraction solvent and the parameters affecting the extraction enrichment factor such as the type and amount of carrier, pH and volume ratio of donor phase and acceptor phase, extraction time, salt-out effect and matrix effect were optimized. Under the optimal extraction conditions (organic liquid membrane phase: [C8MIM][PF6] with 14% TOPO (w/v); donor phase: 4mL, pH 4.5 KH2PO4 with 2M Na2SO4; acceptor phase: 25microL, pH 13 NaOH; extraction time: 8 h), low detection limits (0.1-0.4microg/L, RSDor=0.999) were obtained for all the analytes. The presence of humic acid (0-25mg/L dissolved organic carbon) and bovine serum albumin (0-100 μg/mL) had no significant effect on the extraction efficiency. Good spike recoveries over the range of 82.2-103.2% were obtained when applying the proposed method on five real environmental water samples. These results indicated that this present method was very sensitive and reliable with good repeatabilities and excellent clean-up in water samples. The proposed method confirmed hollow fiber supported ionic liquid membrane based LPME to be robust to monitoring trace levels of sulfadiazine, sulfamerazine, sulfamethazine, sulfadimethoxine and sulfamethoxazole in aqueous samples.
  •  
7.
  • Tao, Yong, et al. (författare)
  • Simultaneous conduction of two- and three-phase hollow-fiber-based liquid-phase microextraction for the determination of aromatic amines in environmental water samples
  • 2009
  • Ingår i: Journal of Chromatography A. - : Elsevier. - 0021-9673 .- 1873-3778. ; 1216:5, s. 756-762
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper describes a simultaneously performed two-/three-phase hollow-fiber-based liquid-phase microextraction (HF-LPME) method for the determination of aromatic amines with a wide range of pKa (-4.25 to 4.6) and log KOW (0.9-2.8) values in environmental water samples. Analytes including aniline, 4-nitroaniline, 2,4-dinitroaniline and dicloran were extracted from basic aqueous samples (donor phase, DP) into the microliter volume of organic membrane phase impregnated into the pores of the polypropylene hollow fiber wall, then back extracted into the acidified aqueous solution (acceptor phase, AP) filling in the lumen of the hollow fiber. The mass transfer of the analytes from the donor phase through the organic membrane phase into acceptor phase was driven by both the counter-coupled transport of hydrogen ions and the pH gradient. Afterwards, the hollow fiber was eluted with 50 microL methanol to capture the analytes from both the organic membrane and the acceptor phase. Factors relevant to the enrichment factors (EFs) were investigated. Under the optimized condition (DP: 100 mL of 0.1 M NaOH with 2 M Na2SO4; organic phase: di-n-hexyl with 8% trioctylphosphine oxide (TOPO); AP: 10 microL of 8 M HCl; extraction time of 80 min), the obtained EFs were 405-2000, dynamic linear ranges were 5-200 microg/L (R>0.9976), and limits of detection were 0.5-1.5 microg/L. The presence of humic acid (0-25 mg/L dissolved organic carbon) had no significant effect on the extraction efficiency. The proposed procedure worked very well for real environmental water samples with microgram per liter level of analytes, and good spike recoveries (80-103%) were obtained.
  •  
8.
  • Zhao, Xiaoli, et al. (författare)
  • Preparation of silica-magnetite nanoparticle mixed hemimicelle sorbents for extraction of several typical phenolic compounds from environmental water samples
  • 2008
  • Ingår i: Journal of Chromatography A. - : Elsevier. - 0021-9673 .- 1873-3778. ; 1188:2, s. 140-147
  • Tidskriftsartikel (refereegranskat)abstract
    • A novel type of superparamagnetic silica-coated (Fe3O4/SiO2 core/shell) magnetite nanoparticle modified by surfactants has been successfully synthesized and was applied as an effective sorbent material for the pre-concentration of several typical phenolic compounds (bisphenol A (BPA), 4-tert-octylphenol (4-OP) and 4-n-nonylphenol (4-NP)) from environmental water samples. Compared with pure magnetic particles, a thin and dense silica layer would protect the iron oxide core from leaching out in acidic conditions. In order to enhance their adsorptive tendency towards organic compounds, cetylpyridinium chloride (CPC) or cetyltrimethylammonium bromide (CTAB) were added, which adsorbed on the surface of the Fe3O4/SiO2 nanoparticles (Fe3O4/SiO2 NPs) and formed mixed hemimicelles. Main factors affecting the adsolubilization of analytes were optimized and comparative study on the use of CPC and CTAB-coated Fe3O4/SiO2 NPs mixed hemimicelles-based SPE was also carried out. CPC-coated Fe3O4/SiO2 NPs system was selected due to lower elution volume required and more effective adsorption of the target compounds. Under selected conditions, concentration factor of 1600 was achieved by using this method to extract 800 mL of different environmental water samples. The detection limits obtained for BPA, 4-OP and 4-NP with HPLC-FLD were 7, 14, and 20 ng/L, respectively.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy