SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0167 5087 ;hsvcat:1"

Sökning: L773:0167 5087 > Naturvetenskap

  • Resultat 1-10 av 154
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Antonov, A. N., et al. (författare)
  • The electron-ion scattering experiment ELISe at the International Facility for Antiproton and Ion Research (FAIR)-A conceptual design study
  • 2011
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002 .- 0167-5087. ; 637:1, s. 60-76
  • Tidskriftsartikel (refereegranskat)abstract
    • The electron-ion scattering experiment ELISe is part of the installations envisaged at the new experimental storage ring at the International Facility for Antiproton and Ion Research (FAIR) in Darmstadt, Germany. It offers an unique opportunity to use electrons as probe in investigations of the structure of exotic nuclei. The conceptual design and the scientific challenges of ELISe are presented. (C) 2011 Elsevier B.V. All rights reserved.
  •  
2.
  • Fritioff, T., et al. (författare)
  • Purification of radioactive neutron-rich argon beams using an ion source in charge breeding mode
  • 2006
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 556:1, s. 31-37
  • Tidskriftsartikel (refereegranskat)abstract
    • Measurements of nuclear properties of some neutron-rich asymmetric fission isotopes at an ISOL laboratory present a severe problem when a plasma ion source is used as the primary ion-source. The problem is associated with intense multi-charged symmetric fission contaminants that cannot be mass-separated from asymmetric fission products. In this work we demonstrate how this problem can be overcome on-line by using an electron cyclotron resonance ion source (ECRIS) as a charge-breeding secondary ion-source. Mixed Ar+/Kr2+/Xe3+ radioactive beams from an plasma ion-source were injected into the PHOENIX ECRIS that currently is installed at the ISOLDE facility at CERN in order to improve the ratio of Ar to the background contaminants of Kr and Xe. The signal to noise ratio was improved by more than two orders of magnitude after charge-breeding and mass-separation of the Ar8+, Ar9+ beams. The information on the decay of the Ar-48 nucleus obtained in these tests is useful for a better understanding of the origin of the Ca-48/Ca-46 meteorite isotopic anomaly. Potential applications of the method are discussed.
  •  
3.
  • Akkoyun, S., et al. (författare)
  • AGATA - Advanced GAmma Tracking Array
  • 2012
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002 .- 0167-5087 .- 1872-9576. ; 668, s. 26-58
  • Tidskriftsartikel (refereegranskat)abstract
    • The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation γ-ray spectrometer. AGATA is based on the technique of γ-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a γ ray deposits its energy within the detector volume. Reconstruction of the full interaction path results in a detector with very high efficiency and excellent spectral response. The realisation of γ-ray tracking and AGATA is a result of many technical advances. These include the development of encapsulated highly segmented germanium detectors assembled in a triple cluster detector cryostat, an electronics system with fast digital sampling and a data acquisition system to process the data at a high rate. The full characterisation of the crystals was measured and compared with detector- response simulations. This enabled pulse-shape analysis algorithms, to extract energy, time and position, to be employed. In addition, tracking algorithms for event reconstruction were developed. The first phase of AGATA is now complete and operational in its first physics campaign. In the future AGATA will be moved between laboratories in Europe and operated in a series of campaigns to take advantage of the different beams and facilities available to maximise its science output. The paper reviews all the achievements made in the AGATA project including all the necessary infrastructure to operate and support the spectrometer. © 2011 Elsevier B.V. All rights reserved.
  •  
4.
  • Björneholm, Olle, et al. (författare)
  • Free clusters studied by core-level spectroscopies
  • 2009
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 601:1-2, s. 161-181
  • Forskningsöversikt (refereegranskat)abstract
    • In this review we describe the development and current status of free clusters studied using core-level spectroscopies. This topic ranges from simple model systems, such as rare gas clusters, to molecular clusters, and clusters of solids, held together by ionic, covalent and metallic bonding.
  •  
5.
  • Blüm, P., et al. (författare)
  • A modular NaI(Tl) detector for 20-1000 MeV photons
  • 1983
  • Ingår i: Nuclear Instruments and Methods in Physics Research. - : Elsevier BV. - 0167-5087. ; 213:2-3, s. 251-259
  • Tidskriftsartikel (refereegranskat)abstract
    • A detector consisting of 54 NaI (Tl) modules is described. The detector has been optimized for the detection of 20-1000 MeV photons. An energy resolution (fwhm) of 5.5% at 130 MeV could be attained, and the stability has been better than 1% over several months.
  •  
6.
  • Jebali, R., et al. (författare)
  • A first comparison of the responses of a He-4-based fast-neutron detector and a NE-213 liquid-scintillator reference detector
  • 2015
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 794, s. 102-108
  • Tidskriftsartikel (refereegranskat)abstract
    • A first comparison has been made between the pulse-shape discrimination characteristics of a novel He-4-based pressurized scintillation detector and a NE-213 liquicl-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between neutrons and gamma-rays were investigated. The NE-213 liquicl-scintillator reference cell produced a wide range of scintillation-light yields in response to he gamma-ray field of the source. In stark contrast, clue to the size and pressure of the He-4 gas volume, the He-4-based detector registered a maximum scintillation-light yield of 750 keV(ee) to the same gamma-ray field. Pulse-shape discrimination for particles with scintillation-light yields of more than 750 keV(ee) was excellent in the case of the He-4-based detector. Above 750 keV(ee) its signal was unambiguously neutron, enabling particle identification based entirely upon the amount of scintillation light produced. (C) 2015 The Authors. Published by Elsevier B.V.
  •  
7.
  • Lalovic, Natasa, et al. (författare)
  • Performance of the AGATA gamma-ray spectrometer in the PreSPEC set-up at GSI
  • 2016
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 806, s. 258-266
  • Tidskriftsartikel (refereegranskat)abstract
    • In contemporary nuclear physics, the European Advanced GAmma Tracking Array (AGATA) represents a crucial detection system for cutting-edge nuclear structure studies. AGATA consists of highly segmented high-purity germanium crystals and uses the pulse-shape analysis technique to determine both the position and the energy of the y-ray interaction points in the crystals. It is the tracking algorithms that deploy this information and enable insight into the sequence of interactions, providing information on the full or partial absorption of the 7 ray. A series of dedicated performance measurements for an AGATA set-up comprising 21 crystals is described. This set-up was used within the recent PreSPEC-AGATA experimental campaign at the GSI Helmholtzzentrum fur Schwerionenforschung. Using the radioactive sources Co-56, Co-60 and Eu-152, absolute and normalized efficiencies and the peak-to-total of the array were measured. These quantities are discussed using different data analysis procedures. The quality of the pulse-shape analysis and the tracking algorithm are evaluated. The agreement between the experimental data and the Geant4 simulations is also investigated.
  •  
8.
  • Makonyi, Karoly, et al. (författare)
  • Evaluating vacuum phototriodes designed for the PANDA electromagnetic calorimeter
  • 2014
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 763, s. 36-43
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work properties of a vacuum phototriode (VPT) and preamplifier unit designed for the electromagnetic calorimeter of the PANDA experiment being built at FAIR are investigated. With the use of lead tungstate and lanthanium bromide scintillators the VPT properties are studied at low photon energies, from tens of key in the lanthanium bromide measurements and between 10 MeV and 60 MeV in the lead tungstate measurements. At these energies the noise of the VPT unit can be expected to influence its performance significantly. It is shown that the noise contribution to the measured energy resolution, under optimal conditions, is consistent with a fluctuation of (one standard deviation) approximately 200 electrons at the VPT anode. For a lead tungstate crystal this is equivalent to a noise of 1.2 MeV. For lanthanium bromide this makes it possible to use VPTs for gamma ray spectroscopy above a few hundreds of keV without noticeable effects on the energy resolution compared to measurements with a standard photomultiplier.
  •  
9.
  • Marcks von Wurtemberg, Klas, et al. (författare)
  • The response of lead-tungstate scintillators (PWO) to photons with energies in the range 13 MeV-64 MeV
  • 2012
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 679, s. 36-43
  • Tidskriftsartikel (refereegranskat)abstract
    • The response of a matrix of 25 lead tungstate (PWO) scintillator detectors, operated at -25 degrees C, to photons in the range 13 MeV-64 MeV has been measured at the tagged-photon facility at MAX-lab, Lund. The tapered PWO crystals, each with a length of 200 mm and a cross-section of 24.4 x 24.4 mm(2) in the front end, read out by 19 mm photomultiplier tubes, were arranged in a 5 x 5 matrix. The response was measured for photons directed towards the centre of the central crystal as well as for photons directed towards the corner of the central crystal, where four crystals meet. The obtained energy resolution surpasses what has been published so far and is close to the limit given by Poisson statistics and escaped energy. For photons directed towards the centre(corner) of the central crystal the relative energy resolution, defined as (FWHM/2.35)/E-gamma, decreases from 7.3%(11.0%) at E-gamma = 13 MeV to 3.3%(3.6%) at E-gamma = 64 MeV. The reconstructed point of impact of a photon in this energy range is determined with an uncertainty (one standard deviation) of 7.3 +/- 0.1 mm.
  •  
10.
  • Murin, Yu., et al. (författare)
  • A detector system for studying nuclear reactions relevant to Single Event Effects
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 578:2, s. 385-398
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe a device to study reactions relevant for the Single Event Effect (SEE) in microelectronics by means of 200A and 300AMeV, inverse kinematics, Si + H and Si + D reactions. The work is focused on the possibility to measure Z = 2-14 projectile fragments as efficiently as possible. During commissioning and first experiments the fourth quadrant of the CELSIUS storage ring acted as a spectrometer to register fragments in two planes of Si strip detectors in the angular region 0 degrees-0.6 degrees. A combination of ring-structured and sector-structured Si strip detector planes operated at angles 0.6 degrees-1.1 degrees. For specific event tagging a Si+ phoswich scintillator wall operated in the range 3.9 degrees-11.7 degrees and Si Delta E-E telescopes of CHICSi type operated at large angles.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 154
Språk
Engelska (154)
Forskningsämne (UKÄ/SCB)
Teknik (12)
Lantbruksvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy