SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0167 5087 ;pers:(Anderberg B)"

Sökning: L773:0167 5087 > Anderberg B

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Anderberg, B, et al. (författare)
  • The design of a 3 GHz thermionic RF-gun and energy filter for MAX-lab
  • 2002
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 491:1-2, s. 307-313
  • Tidskriftsartikel (refereegranskat)abstract
    • A new pre-injector has been designed for the MAX-laboratory. It consists of an RF-gun and a magnetic energy filter. The newly designed RF-gun geometry will be operated at 3 GHz in the thermionic mode using a BaO cathode. The pre-injector will provide a 2.3 MeV electron beam in 3 ps micro pulses to a new injector system currently under construction. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
2.
  • Lindgren, Lars-Johan, et al. (författare)
  • Septum magnet design
  • 2002
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 490:3, s. 592-597
  • Tidskriftsartikel (refereegranskat)abstract
    • New magnetic DC septa are designed for the upgraded Max I and the new Max III storage rings, respectively. The new septum is made magnetically symmetric with a magnetic flux filter in the septum nose, The residual stray fields in the ring tube become almost linear and the usually strong stray fields close to the septum sheet are eliminated. If necessary a final correction of the linear part could be done in the injection straight.
  •  
3.
  • Lindgren, Lars-Johan, et al. (författare)
  • The new septum magnets
  • 2005
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 547:2-3, s. 686-689
  • Tidskriftsartikel (refereegranskat)abstract
    • In an earlier paper we reported on a new septum magnet design with a magnetic flux filter [1]. Now the first septum magnet is in operation as in injection septum magnet for the MAX I storage ring. We dcscribe the actual mechanical construction and the field measurements of the new magnets. The fine Structure of the septum nose needed several trials in the construction until we found the final solution. The measured residual stray fields in the ring tube are even smaller than was expected from the model calculations.
  •  
4.
  • Tarawneh, Hamed, et al. (författare)
  • MAX-IV lattice, dynamic properties and magnet system
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 508:3, s. 480-486
  • Tidskriftsartikel (refereegranskat)abstract
    • At MAX-LAB the next synchrotron light source MAX-IV is currently studied (Proceedings of the seventh European Particle Accelerator Conference, EPAC 02, Paris, France, 2002). In this paper, we present a possible lattice with horizontal emittance of 1.2 nm rad at an energy of 3 GeV. The possibilities to realise the main magnetic system with high gradient integrated magnets are studied with 2D and 3D magnetic field programs. The dynamic properties for the lattice are also studied and some higher order corrections are discussed. (C) 2003 Elsevier B.V. All rights reserved.
  •  
5.
  • Tarawneh, Hamed, et al. (författare)
  • Prototype soft end dipole magnet for MAX-IV, fabrication and measurements
  • 2005
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 546:3, s. 620-626
  • Tidskriftsartikel (refereegranskat)abstract
    • The MAX-IV storage rings are being studied at MAX-Lab. In this paper, we present the magnetic measurements of the soft bending magnet prototype. The magnet is introduced in the matching section of the 3 GeV storage ring lattice [Tarawneh, Proceedings of European Particle Accelerator Conference, July 2004, Lucerne, Switzerland] mainly to reduce the power of the synchrotron radiation hitting the upstream superconducting insertion devices.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5
Typ av publikation
tidskriftsartikel (5)
Typ av innehåll
refereegranskat (5)
Författare/redaktör
Lindgren, Lars-Johan (4)
Eriksson, Mikael (2)
Tarawneh, Hamed (2)
Andersson, Åke (1)
Demirkan, Medine (1)
visa fler...
Malmgren, Lars (1)
Werin, Sverker (1)
visa färre...
Lärosäte
Lunds universitet (5)
Språk
Engelska (5)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (5)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy