SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0340 6997 ;pers:(Persson Bertil R.R.)"

Sökning: L773:0340 6997 > Persson Bertil R.R.

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Darte, Lennart, et al. (författare)
  • Quality control of 99mTc-radiopharmaceuticals - Evaluation of GCS minicolumns in routine clinical work with scintillation cameras
  • 1980
  • Ingår i: European Journal Of Nuclear Medicine. - 0340-6997. ; 5:6, s. 521-527
  • Tidskriftsartikel (refereegranskat)abstract
    • Gel chromatography column scanning (GCS) is a rapid and reliable method for the quality control of 99mTc-radiopharmaceuticals. With this method the labelled compound and various impurities such as free pertechnetate, hydrolyzed reduced technetium or other 99mTc-complexes are obtained in one testing procedure. Using minicolumns results can be obtained with a simple testing procedure within a few minutes after the sample is taken; this is significant in routine radiopharmaceutical work. The resolution of the recording system is important, so as to be able to utilize fully the good separation ability of the minicolumn. Minicolumns were studied with some commonly used radiopharmaceuticals. A scintillation camera was used to record minicolumn data under various conditions and the results were compared to those obtained using a scanner to reveal optimal recording conditions for the scintillation camera.
  •  
2.
  • Strand, Sven Erik, et al. (författare)
  • The dual photopeak-area method applied to scintillation camera measurements of effective depth and activity of in vivo 123I-distributions
  • 1977
  • Ingår i: European Journal Of Nuclear Medicine. - 0340-6997. ; 2:2, s. 121-128
  • Tidskriftsartikel (refereegranskat)abstract
    • Attenuation curves and photopeak ratios of 159 keV and 28 keV phtons emitted in the decay of 123I have been studied using a scintillation camera equipped with an extra ADC for recording the pulse height distribution of the energy signal. Cavities of various sizes containing 123I-solution were placed at different depths in a water phantom in order to vary the effective depth, i.e., the thickness of attenuating material above the cavity plus the distance to the centre of activity in the cavity. The centre of activity varies with the distribution of activity in the cavity, size of cavity, and the effective attenuation coefficient derived from the attenuation curves. From the photopeak ratio an average effective depth is determined which can be used for calculating the attenuation correction factor. The dual photopeak ratio has been used in clinical evaluation of thyroid 123I uptake measurements where effective depths ranging from 21 to 43 mm were obtained for the activity in the thyroid. Applications of the photopeak ratio method for renography with 123I-hippuran and blood flow studies using 133Xe or 127Xe and studies with many other radionuclides are also discussed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Strand, Sven-Erik (1)
Darte, Lennart (1)
Lärosäte
Lunds universitet (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy