SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1473 5598
 

Sökning: L773:1473 5598 > Chalmers tekniska högskola > Accuracy of colour ...

Accuracy of colour duplex sonography for the diagnosis of renal artery stenosis.

Saeed, Aso, 1971 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,University of Gothenburg
Bergström, Göran, 1964 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,University of Gothenburg
Zachrisson, Karin (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences,University of Gothenburg
visa fler...
Guron, Gregor, 1967 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,University of Gothenburg
Nowakowska-Fortuna, Elzbieta (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,University of Gothenburg
Fredriksen, Ellen (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,University of Gothenburg
Lönn, Lars, 1956 (författare)
Jensen, Gert, 1950 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,University of Gothenburg
Herlitz, Hans, 1946 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för molekylär och klinisk medicin,Institute of Medicine, Department of Molecular and Clinical Medicine,University of Gothenburg
visa färre...
 (creator_code:org_t)
2009
2009
Engelska.
Ingår i: Journal of hypertension. - 1473-5598. ; 27:8, s. 1690-6
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVE: To examine the diagnostic value of novel velocimetric colour duplex sonography indices in the screening of renal artery stenosis (RAS). METHODS: We performed a retrospective analysis of all consecutively studied patients at our centre with suspected RAS, and a colour duplex sonography carried out at less than 4 months (mean 34 days) before renal angiography during a 6-year period (2002-2007). A significant RAS was defined as an at least 60% stenosis on angiography or a transstenotic mean arterial pressure gradient of at least 10 mmHg or both. RESULTS: In a total of 169 patients, 111 stenotic and 206 nonstenotic kidneys were examined. The sensitivity and specificity for acceleration of blood flow in early systole (ACCmax) were 85 and 75%, respectively, and for the acceleration index (ACCmax/peak systolic velocity, AImax) 83 and 79%, respectively. Corresponding values in patients with estimated glomerular filtration rate of less than 30 ml/min/1.73 m2 were 90 and 73% (for ACCmax) and 74 and 88% (for AImax). In addition, the transstenotic mean arterial pressure gradient showed a significant, though weak, negative correlation to ACCmax (r = -0.26, P = 0.02) and AImax (r = -0.29, P = 0.01) in stenotic kidneys. CONCLUSION: ACCmax and AImax provide similar, good diagnostic accuracy in the detection of a haemodynamically significant RAS, even in patients with markedly reduced glomerular filtration rate. Presumably, the lack of superiority of the novel index AImax could be explained by a highly homogenous methodological approach in the present single-centre study.

Nyckelord

Adult
Aged
Female
Glomerular Filtration Rate
Humans
Male
Middle Aged
Renal Artery Obstruction
physiopathology
ultrasonography
Retrospective Studies
Systole
Ultrasonography
Doppler
Duplex
methods
Humans

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy