1.
  • Fredriksson, Alexandru Grigorescu, et al. (författare)
  • Turbulent kinetic energy in the right ventricle : Potential MR marker for risk stratification of adults with repaired Tetralogy of Fallot
  • 2018
  • Ingår i: Journal of Magnetic Resonance Imaging. - Hoboken : John Wiley & Sons. - 1053-1807 .- 1522-2586. ; 47:4, s. 1043-1053
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To assess right ventricular (RV) turbulent kinetic energy (TKE) in patients with repaired Tetralogy of Fallot (rToF) and a spectrum of pulmonary regurgitation (PR), as well as to investigate the relationship between these 4D flow markers and RV remodeling.Materials and Methods: Seventeen patients with rToF and 10 healthy controls were included in the study. Patients were divided into two groups based on PR fraction: one lower PR fraction group (11%) and one higher PR fraction group (>11%). Field strength/sequences: 3D cine phase contrast (4D flow), 2D cine phase contrast (2D flow), and balanced steady-state free precession (bSSFP) at 1.5T. Assessment: The RV volume was segmented in the morphologic short-axis images and TKE parameters were computed inside the segmented RV volume throughout diastole. Statistical tests: One-way analysis of variance with Bonferroni post-hoc test; unpaired t-test; Pearson correlation coefficients; simple and stepwise multiple regression models; intraclass correlation coefficient (ICC).Results: The higher PR fraction group had more remodeled RVs (140 6 25 vs. 107 6 22 [lower PR fraction, P < 0.01] and 93 6 15 ml/m2[healthy, P < 0.001] for RV end-diastolic volume index [RVEDVI]) and higher TKE values (5.95 6 3.15 vs. 2.23 6 0.81 [lower PR fraction, P < 0.01] and 1.91 6 0.78 mJ [healthy, P < 0.001] for Peak Total RV TKE). Multiple regression analysis between RVEDVI and 4D/2D flow parameters showed that Peak Total RV TKE was the strongest predictor of RVEDVI (R25 0.47, P 5 0.002).Conclusion: The 4D flow-specific TKE markers showed a slightly stronger association with RV remodeling than conventional 2D flow PR parameters. These results suggest novel hemodynamic aspects of PR in the development of late complications after ToF repair.
  •  
2.
  •  
3.
  • Dyverfeldt, Petter, et al. (författare)
  • Reduction of motion artifacts in carotid MRI using free-induction decay navigators
  • 2014
  • Ingår i: Journal of Magnetic Resonance Imaging. - : John Wiley & Sons. - 1053-1807 .- 1522-2586. ; 40:1, s. 214-220
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE:To develop a framework for prospective free-induction decay (FID)-based navigator gating for suppression of motion artifacts in carotid magnetic resonance imaging (MRI) and to assess its capability in vivo.MATERIALS AND METHODS:An FID-navigator, comprising a spatially selective low flip-angle sinc-pulse followed by an analog-to-digital converter (ADC) readout, was added to a conventional turbo spin-echo (TSE) sequence. Real-time navigator processing delivered accept/reject-and-reacquire decisions to the sequence. In this Institutional Review Board (IRB)-approved study, seven volunteers were scanned with a 2D T2-weighted TSE sequence. A reference scan with volunteers instructed to minimize motion as well as nongated and gated scans with volunteers instructed to perform different motion tasks were performed in each subject. Multiple image quality measures were employed to quantify the effect of gating.RESULTS:There was no significant difference in lumen-to-wall sharpness (2.3 ± 0.3 vs. 2.3 ± 0.4), contrast-to-noise ratio (CNR) (9.0 ± 2.0 vs. 8.5 ± 2.0), or image quality score (3.1 ± 0.9 vs. 2.6 ± 1.2) between the reference and gated images. For images acquired during motion, all image quality measures were higher (P < 0.05) in the gated compared to nongated images (sharpness: 2.3 ± 0.4 vs. 1.8 ± 0.5, CNR: 8.5 ± 2.0 vs. 7.2 ± 2.0, score: 2.6 ± 1.2 vs. 1.8 ± 1.0).CONCLUSION:Artifacts caused by the employed motion tasks deteriorated image quality in the nongated scans. These artifacts were alleviated with the proposed FID-navigator.
  •  
4.
  • Hansson, Boel, et al. (författare)
  • Subjectively Reported Effects Experienced in an Actively Shielded 7T MRI: A Large-Scale Study.
  • 2020
  • Ingår i: Journal of magnetic resonance imaging : JMRI. - : Wiley. - 1522-2586 .- 1053-1807. ; 52:4, s. 1265-1276
  • Tidskriftsartikel (refereegranskat)abstract
    • Ultrahigh-field (UHF) MRI advances towards clinical use. Patient compliance is generally high, but few large-scale studies have investigated the effects experienced in 7T MRI systems, especially considering peripheral nerve stimulation (PNS) and caregiving.To evaluate the quantity, the intensity, and subjective experiences from short-term effects, focusing on the levels of comfort and compliance of subjects.Prospective.In all, 954 consecutive MRIs in 801 subjects for 3years.7T.After the 7T examination, a questionnaire was used to collect data.Descriptive statistics, Spearman's rank correlation, Mann-Whitney U-test, and t-test.The majority (63%) of subjects agreed that the MRI experience was comfortable and 93% would be willing to undergo future 7T MRI as a patient (5% undecided) and 82% for research purposes (12% undecided). The most common short-term effects experienced were dizziness (81%), inconsistent movement (68%), PNS (63%), headache (40%), nausea (32%), metallic taste (12%), and light flashes (8%). Of the subjects who reported having PNS (n = 603), 44% experienced PNS as "not uncomfortable at all," 45% as "little or very little uncomfortable," and 11% as "moderate to very much uncomfortable." Scanner room temperature was experienced more comfortable before (78%) than during (58%) examinations, and the noise level was acceptable by 90% of subjects. Anxiety before the examination was reported by 43%. Patients differed from healthy volunteers regarding an experience of headache, metallic taste, dizziness, or anxiety. Room for improvement was pointed out after 117 examinations concerning given information (n = 73), communication and sound system (n = 35), or nursing care (n = 15).Subjectively reported effects occur in actively shielded 7T MRI and include physiological responses and individual psychological issues. Although leaving room for improvement, few subjects experienced these effects being so uncomfortable that they would lead to aversion to future UHF examinations.1 TECHNICAL EFFICACY: Stage 5.
  •  
5.
  • Holmgren, Madelene, et al. (författare)
  • Assessment of Cerebral Blood Flow Pulsatility and Cerebral Arterial Compliance With 4D Flow MRI
  • 2020
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley-Blackwell. - 1053-1807 .- 1522-2586. ; 51:5, s. 1516-1525
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Four-dimensional flow magnetic resonance imaging (4D flow MRI) enables efficient investigation of cerebral blood flow pulsatility in the cerebral arteries. This is important for exploring hemodynamic mechanisms behind vascular diseases associated with arterial pulsations.PURPOSE: To investigate the feasibility of pulsatility assessments with 4D flow MRI, its agreement with reference two-dimensional phase-contrast MRI (2D PC-MRI) measurements, and to demonstrate how 4D flow MRI can be used to assess cerebral arterial compliance and cerebrovascular resistance in major cerebral arteries.STUDY TYPE: Prospective.SUBJECTS: Thirty-five subjects (20 women, 79 ± 5 years, range 70-91 years).FIELD STRENGTH/SEQUENCE: 4D flow MRI (PC-VIPR) and 2D PC-MRI acquired with a 3T scanner.ASSESSMENT: Time-resolved flow was assessed in nine cerebral arteries. From the pulsatile flow waveform in each artery, amplitude (ΔQ), volume load (ΔV), and pulsatility index (PI) were calculated. To reduce high-frequency noise in the 4D flow MRI data, the flow waveforms were low-pass filtered. From the total cerebral blood flow, total PI (PItot ), total volume load (ΔVtot ), cerebral arterial compliance (C), and cerebrovascular resistance (R) were calculated.STATISTICAL TESTS: Two-tailed paired t-test, intraclass correlation (ICC).RESULTS: There was no difference in ΔQ between 4D flow MRI and the reference (0.00 ± 0.022 ml/s, mean ± SEM, P = 0.97, ICC = 0.95, n = 310) with a cutoff frequency of 1.9 Hz and 15 cut plane long arterial segments. For ΔV, the difference was -0.006 ± 0.003 ml (mean ± SEM, P = 0.07, ICC = 0.93, n = 310) without filtering. Total R was 11.4 ± 2.41 mmHg/(ml/s) (mean ± SD) and C was 0.021 ± 0.009 ml/mmHg (mean ± SD). ΔVtot was 1.21 ± 0.29 ml (mean ± SD) with an ICC of 0.82 compared with the reference. PItot was 1.08 ± 0.21 (mean ± SD).DATA CONCLUSION: We successfully assessed 4D flow MRI cerebral arterial pulsatility, cerebral arterial compliance, and cerebrovascular resistance. Averaging of multiple cut planes and low-pass filtering was necessary to assess accurate peak-to-peak features in the flow rate waveforms.LEVEL OF EVIDENCE: 2Technical Efficacy Stage: 2
  •  
6.
  • Zajac, Jacub, et al. (författare)
  • Turbulent Kinetic Energy in Normal and Myopathic Left Ventricles
  • 2015
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley-Blackwell. - 1053-1807 .- 1522-2586. ; 41:4, s. 1021-1029
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To assess turbulent kinetic energy (TKE) within the left ventricle (LV) of healthy subjects using novel 4D flow MRI methods and to compare TKE values to those from a spectrum of patients with dilated cardiomyopathy (DCM).Methods: 4D flow and morphological MRI-data were acquired in 11 healthy subjects and 9 patients with different degrees of diastolic dysfunction. TKELV was calculated within the LV at each diastolic time frame. At peak early (E) and late (A) diastolic filling, the TKELV was compared to transmitral peak velocity, LV diameter and mitral annular diameter.Results: In the majority of all subjects, peaks in TKELV could be observed at E and A. Peak TKELV at E was not different between the groups, and correlated with mitral annular dimensions. Peak TKELV at A was higher in DCM patients compared to healthy subjects, and was related to LV diameter and transmitral velocity.Conclusions: In normal LVs, TKE values are low. Values are highest during early diastole, and diminish with increasing LV size. In a heterogeneous group of DCM patients, late diastolic TKE values are higher than in healthy subjects. Kinetic energy loss due to elevated late diastolic TKE may reflect inefficient flow in dilated LVs.
  •  
7.
  • Andersson, Thord, et al. (författare)
  • Consistent intensity inhomogeneity correction in water-fat MRI
  • 2015
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley-Blackwell. - 1053-1807 .- 1522-2586. ; 42:2
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To quantitatively and qualitatively evaluate the water-signal performance of the consistent intensity inhomogeneity correction (CIIC) method to correct for intensity inhomogeneitiesMETHODS: Water-fat volumes were acquired using 1.5 Tesla (T) and 3.0T symmetrically sampled 2-point Dixon three-dimensional MRI. Two datasets: (i) 10 muscle tissue regions of interest (ROIs) from 10 subjects acquired with both 1.5T and 3.0T whole-body MRI. (ii) Seven liver tissue ROIs from 36 patients imaged using 1.5T MRI at six time points after Gd-EOB-DTPA injection. The performance of CIIC was evaluated quantitatively by analyzing its impact on the dispersion and bias of the water image ROI intensities, and qualitatively using side-by-side image comparisons.RESULTS: CIIC significantly ( P1.5T≤2.3×10-4,P3.0T≤1.0×10-6) decreased the nonphysiological intensity variance while preserving the average intensity levels. The side-by-side comparisons showed improved intensity consistency ( Pint⁡≤10-6) while not introducing artifacts ( Part=0.024) nor changed appearances ( Papp≤10-6).CONCLUSION: CIIC improves the spatiotemporal intensity consistency in regions of a homogenous tissue type.
  •  
8.
  • Bustamante, Mariana, et al. (författare)
  • Automatic Time-Resolved Cardiovascular Segmentation of 4D Flow MRI Using Deep Learning
  • 2023
  • Ingår i: Journal of Magnetic Resonance Imaging. - Hoboken, NJ, United States : John Wiley & Sons. - 1053-1807 .- 1522-2586. ; 57:1, s. 191-203
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Segmenting the whole heart over the cardiac cycle in 4D flow MRI is a challenging and time-consuming process, as there is considerable motion and limited contrast between blood and tissue.Purpose To develop and evaluate a deep learning-based segmentation method to automatically segment the cardiac chambers and great thoracic vessels from 4D flow MRI. Study Type Retrospective.Subjects A total of 205 subjects, including 40 healthy volunteers and 165 patients with a variety of cardiac disorders were included. Data were randomly divided into training (n = 144), validation (n = 20), and testing (n = 41) sets.Field Strength/Sequence A 3 T/time-resolved velocity encoded 3D gradient echo sequence (4D flow MRI).Assessment A 3D neural network based on the U-net architecture was trained to segment the four cardiac chambers, aorta, and pulmonary artery. The segmentations generated were compared to manually corrected atlas-based segmentations. End-diastolic (ED) and end-systolic (ES) volumes of the four cardiac chambers were calculated for both segmentations.Statistical tests Dice score, Hausdorff distance, average surface distance, sensitivity, precision, and miss rate were used to measure segmentation accuracy. Bland-Altman analysis was used to evaluate agreement between volumetric parameters.Results The following evaluation metrics were computed: mean Dice score (0.908 +/- 0.023) (mean +/- SD), Hausdorff distance (1.253 +/- 0.293 mm), average surface distance (0.466 +/- 0.136 mm), sensitivity (0.907 +/- 0.032), precision (0.913 +/- 0.028), and miss rate (0.093 +/- 0.032). Bland-Altman analyses showed good agreement between volumetric parameters for all chambers. Limits of agreement as percentage of mean chamber volume (LoA%), left ventricular: 9.3%, 13.5%, left atrial: 12.4%, 16.9%, right ventricular: 9.9%, 15.6%, and right atrial: 18.7%, 14.4%; for ED and ES, respectively.Data conclusion The addition of this technique to the 4D flow MRI assessment pipeline could expedite and improve the utility of this type of acquisition in the clinical setting. Evidence Level 4Technical Efficacy Stage 1
  •  
9.
  • Bustamante, Mariana, et al. (författare)
  • Using Deep Learning to Emulate the Use of an External Contrast Agent in Cardiovascular 4D Flow MRI
  • 2021
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 54:3, s. 777-786
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Although contrast agents would be beneficial, they are seldom used in four-dimensional (4D) flow magnetic resonance imaging (MRI) due to potential side effects and contraindications. Purpose To develop and evaluate a deep learning architecture to generate high blood-tissue contrast in noncontrast 4D flow MRI by emulating the use of an external contrast agent. Study Type Retrospective. Subjects Of 222 data sets, 141 were used for neural network (NN) training (69 with and 72 without contrast agent). Evaluation was performed on the remaining 81 noncontrast data sets. Field Strength/Sequences Gradient echo or echo-planar 4D flow MRI at 1.5 T and 3 T. Assessment A cyclic generative adversarial NN was trained to perform image translation between noncontrast and contrast data. Evaluation was performed quantitatively using contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), structural similarity index (SSIM), mean squared error (MSE) of edges, and Dice coefficient of segmentations. Three observers performed a qualitative assessment of blood-tissue contrast, noise, presence of artifacts, and image structure visualization. Statistical Tests The Wilcoxon rank-sum test evaluated statistical significance. Kendalls concordance coefficient assessed interobserver agreement. Results Contrast in the regions of interest (ROIs) in the NN enhanced images increased by 88%, CNR increased by 63%, and SNR improved by 48% (all P < 0.001). The SSIM was 0.82 +/- 0.01, and the MSE of edges was 0.09 +/- 0.01 (range [0,1]). Segmentations based on the generated images resulted in a Dice similarity increase of 15.25%. The observers managed to differentiate between contrast MR images and our results; however, they preferred the NN enhanced images in 76.7% of cases. This percentage increased to 93.3% for phase-contrast MR angiograms created from the NN enhanced data. Visual grading scores were blood-tissue contrast = 4.30 +/- 0.74, noise = 3.12 +/- 0.98, and presence of artifacts = 3.63 +/- 0.76. Image structures within and without the ROIs resulted in scores of 3.42 +/- 0.59 and 3.07 +/- 0.71, respectively (P < 0.001). Data Conclusion The proposed approach improves blood-tissue contrast in MR images and could be used to improve data quality, visualization, and postprocessing of cardiovascular 4D flow data. Evidence Level 3 Technical Efficacy Stage 1
  •  
10.
  • Cibis, Merih, et al. (författare)
  • Creating Hemodynamic Atlases of Cardiac 4D Flow MRI
  • 2017
  • Ingår i: Journal of Magnetic Resonance Imaging. - : WILEY. - 1053-1807 .- 1522-2586. ; 46:5, s. 1389-1399
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Hemodynamic atlases can add to the pathophysiological understanding of cardiac diseases. This study proposes a method to create hemodynamic atlases using 4D Flow magnetic resonance imaging (MRI). The method is demonstrated for kinetic energy (KE) and helicity density (Hd). Materials and Methods: Thirteen healthy subjects underwent 4D Flow MRI at 3T. Phase-contrast magnetic resonance cardioangiographies (PC-MRCAs) and an average heart were created and segmented. The PC-MRCAs, KE, and Hd were nonrigidly registered to the average heart to create atlases. The method was compared with 1) rigid, 2) affine registration of the PC-MRCAs, and 3) affine registration of segmentations. The peak and mean KE and Hd before and after registration were calculated to evaluate interpolation error due to nonrigid registration. Results: The segmentations deformed using nonrigid registration overlapped (median: 92.3%) more than rigid (23.1%, P amp;lt; 0.001), and affine registration of PC-MRCAs (38.5%, P amp;lt; 0.001) and affine registration of segmentations (61.5%, P amp;lt; 0.001). The peak KE was 4.9 mJ using the proposed method and affine registration of segmentations (P50.91), 3.5 mJ using rigid registration (P amp;lt; 0.001), and 4.2 mJ using affine registration of the PC-MRCAs (P amp;lt; 0.001). The mean KE was 1.1 mJ using the proposed method, 0.8 mJ using rigid registration (P amp;lt; 0.001), 0.9 mJ using affine registration of the PC-MRCAs (P amp;lt; 0.001), and 1.0 mJ using affine registration of segmentations (P50.028). The interpolation error was 5.262.6% at mid-systole, 2.863.8% at early diastole for peak KE; 9.669.3% at mid-systole, 4.064.6% at early diastole, and 4.964.6% at late diastole for peak Hd. The mean KE and Hd were not affected by interpolation. Conclusion: Hemodynamic atlases can be obtained with minimal user interaction using nonrigid registration of 4D Flow MRI. Level of Evidence: 2 Technical Efficacy: Stage 1
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 28
Typ av publikation
tidskriftsartikel (27)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (27)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Romu, Thobias (4)
Borga, Magnus (4)
Dahlqvist Leinhard, ... (4)
Ebbers, Tino (4)
Wåhlin, Anders (3)
Carlhäll, Carljohan (3)
visa fler...
Johansson, Lars (2)
Karlsson, Anette (2)
Ahlström, Håkan (2)
Eklund, Anders (2)
Helms, Gunther (2)
Frimmel, Hans (2)
Persson, Anders (2)
Engvall, Jan (2)
Kullberg, Joel (2)
Malm, Jan (2)
Smedby, Örjan (1)
Smedby, Örjan, 1956- (1)
Kechagias, Stergios (1)
Lundberg, Peter (1)
Kihlberg, Johan (1)
Larsson, Martin (1)
Carlsson, Marcus (1)
Engvall, Jan, 1953- (1)
Knutsson, Hans (1)
Nilsson, Markus (1)
Björkman-Burtscher, ... (1)
Eriksson, Per (1)
Arheden, Håkan (1)
Berglund, Johan (1)
Wigström, Lars (1)
Hansson, Stefan (1)
Hockings, Paul, 1956 (1)
Almer, Sven (1)
Lönn, Lars, 1956 (1)
Borgefors, Gunilla (1)
Greenwood, Richard (1)
Heiberg, Einar (1)
Enerbäck, Sven, 1958 (1)
Malmberg, Filip (1)
Ambarki, Khalid (1)
Birgander, Richard (1)
Warntjes, Marcel Jan ... (1)
Malm, Jan, Professor ... (1)
Hauksson, Jon (1)
Andersson, Thord (1)
Norén, Bengt (1)
Forsgren, Mikael (1)
Hedström, Erik (1)
Angelhed, Jan-Erik, ... (1)
visa färre...
Lärosäte
Linköpings universitet (18)
Lunds universitet (5)
Göteborgs universitet (3)
Umeå universitet (3)
Uppsala universitet (3)
Kungliga Tekniska Högskolan (1)
visa fler...
Chalmers tekniska högskola (1)
Karolinska Institutet (1)
visa färre...
Språk
Engelska (28)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (14)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy