SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1522 2586 ;pers:(Björkman Burtscher Isabella)"

Sökning: L773:1522 2586 > Björkman Burtscher Isabella

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Fagan, A. J., et al. (författare)
  • 7T MR Safety
  • 2021
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 53:2333-346, s. 333-346
  • Tidskriftsartikel (refereegranskat)abstract
    • Magnetic resonance imaging and spectroscopy (MRI/MRS) at 7T represents an exciting advance in MR technology, with intriguing possibilities to enhance image spatial, spectral, and contrast resolution. To ensure the safe use of this technology while still harnessing its potential, clinical staff and researchers need to be cognizant of some safety concerns arising from the increased magnetic field strength and higher Larmor frequency. The higher static magnetic fields give rise to enhanced transient bioeffects and an increased risk of adverse incidents related to electrically conductive implants. Many technical challenges remain and the continuing rapid pace of development of 7T MRI/MRS is likely to present further challenges to ensuring safety of this technology in the years ahead. The recent regulatory clearance for clinical diagnostic imaging at 7T will likely increase the installed base of 7T systems, particularly in hospital environments with little prior ultrahigh-field MR experience. Informed risk/benefit analyses will be required, particularly where implant manufacturer-published 7T safety guidelines for implants are unavailable. On behalf of the International Society for Magnetic Resonance in Medicine, the aim of this article is to provide a reference document to assist institutions developing local institutional policies and procedures that are specific to the safe operation of 7T MRI/MRS. Details of current 7T technology and the physics underpinning its functionality are reviewed, with the aim of supporting efforts to expand the use of 7T MRI/MRS in both research and clinical environments. Current gaps in knowledge are also identified, where additional research and development are required. Level of Evidence 5 Technical Efficacy 2
  •  
2.
  • Hansson, Boel, et al. (författare)
  • Subjectively Reported Effects Experienced in an Actively Shielded 7T MRI: A Large-Scale Study.
  • 2020
  • Ingår i: Journal of magnetic resonance imaging : JMRI. - : Wiley. - 1522-2586 .- 1053-1807. ; 52:4, s. 1265-1276
  • Tidskriftsartikel (refereegranskat)abstract
    • Ultrahigh-field (UHF) MRI advances towards clinical use. Patient compliance is generally high, but few large-scale studies have investigated the effects experienced in 7T MRI systems, especially considering peripheral nerve stimulation (PNS) and caregiving.To evaluate the quantity, the intensity, and subjective experiences from short-term effects, focusing on the levels of comfort and compliance of subjects.Prospective.In all, 954 consecutive MRIs in 801 subjects for 3years.7T.After the 7T examination, a questionnaire was used to collect data.Descriptive statistics, Spearman's rank correlation, Mann-Whitney U-test, and t-test.The majority (63%) of subjects agreed that the MRI experience was comfortable and 93% would be willing to undergo future 7T MRI as a patient (5% undecided) and 82% for research purposes (12% undecided). The most common short-term effects experienced were dizziness (81%), inconsistent movement (68%), PNS (63%), headache (40%), nausea (32%), metallic taste (12%), and light flashes (8%). Of the subjects who reported having PNS (n = 603), 44% experienced PNS as "not uncomfortable at all," 45% as "little or very little uncomfortable," and 11% as "moderate to very much uncomfortable." Scanner room temperature was experienced more comfortable before (78%) than during (58%) examinations, and the noise level was acceptable by 90% of subjects. Anxiety before the examination was reported by 43%. Patients differed from healthy volunteers regarding an experience of headache, metallic taste, dizziness, or anxiety. Room for improvement was pointed out after 117 examinations concerning given information (n = 73), communication and sound system (n = 35), or nursing care (n = 15).Subjectively reported effects occur in actively shielded 7T MRI and include physiological responses and individual psychological issues. Although leaving room for improvement, few subjects experienced these effects being so uncomfortable that they would lead to aversion to future UHF examinations.1 TECHNICAL EFFICACY: Stage 5.
  •  
3.
  •  
4.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy