SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1522 2586 ;pers:(Ebbers Tino 1972)"

Sökning: L773:1522 2586 > Ebbers Tino 1972

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Dyverfeldt, Petter, 1980-, et al. (författare)
  • Assessment of fluctuating velocities in disturbed cardiovascular blood flow : in vivo feasibility of generalized phase-contrast MRI
  • 2008
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 28:3, s. 655-663
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeTo evaluate the feasibility of generalized phase-contrast magnetic resonance imaging (PC-MRI) for the noninvasive assessment of fluctuating velocities in cardiovascular blood flow.Materials and MethodsMultidimensional PC-MRI was used in a generalized manner to map mean flow velocities and intravoxel velocity standard deviation (IVSD) values in one healthy aorta and in three patients with different cardiovascular diseases. The acquired data were used to assess the kinetic energy of both the mean (MKE) and the fluctuating (TKE) velocity field.ResultsIn all of the subjects, both mean and fluctuating flow data were successfully acquired. The highest TKE values in the patients were found at sites characterized by abnormal flow conditions. No regional increase in TKE was found in the normal aorta.ConclusionPC-MRI IVSD mapping is able to detect flow abnormalities in a variety of human cardiovascular conditions and shows promise for the quantitative assessment of turbulence. This approach may assist in clarifying the role of disturbed hemodynamics in cardiovascular diseases.
  •  
2.
  • Fredriksson, Alexandru Grigorescu, et al. (författare)
  • Turbulent kinetic energy in the right ventricle : Potential MR marker for risk stratification of adults with repaired Tetralogy of Fallot
  • 2018
  • Ingår i: Journal of Magnetic Resonance Imaging. - Hoboken : John Wiley & Sons. - 1053-1807 .- 1522-2586. ; 47:4, s. 1043-1053
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To assess right ventricular (RV) turbulent kinetic energy (TKE) in patients with repaired Tetralogy of Fallot (rToF) and a spectrum of pulmonary regurgitation (PR), as well as to investigate the relationship between these 4D flow markers and RV remodeling.Materials and Methods: Seventeen patients with rToF and 10 healthy controls were included in the study. Patients were divided into two groups based on PR fraction: one lower PR fraction group (11%) and one higher PR fraction group (>11%). Field strength/sequences: 3D cine phase contrast (4D flow), 2D cine phase contrast (2D flow), and balanced steady-state free precession (bSSFP) at 1.5T. Assessment: The RV volume was segmented in the morphologic short-axis images and TKE parameters were computed inside the segmented RV volume throughout diastole. Statistical tests: One-way analysis of variance with Bonferroni post-hoc test; unpaired t-test; Pearson correlation coefficients; simple and stepwise multiple regression models; intraclass correlation coefficient (ICC).Results: The higher PR fraction group had more remodeled RVs (140 6 25 vs. 107 6 22 [lower PR fraction, P < 0.01] and 93 6 15 ml/m2[healthy, P < 0.001] for RV end-diastolic volume index [RVEDVI]) and higher TKE values (5.95 6 3.15 vs. 2.23 6 0.81 [lower PR fraction, P < 0.01] and 1.91 6 0.78 mJ [healthy, P < 0.001] for Peak Total RV TKE). Multiple regression analysis between RVEDVI and 4D/2D flow parameters showed that Peak Total RV TKE was the strongest predictor of RVEDVI (R25 0.47, P 5 0.002).Conclusion: The 4D flow-specific TKE markers showed a slightly stronger association with RV remodeling than conventional 2D flow PR parameters. These results suggest novel hemodynamic aspects of PR in the development of late complications after ToF repair.
  •  
3.
  •  
4.
  • Thunberg, Per, 1968-, et al. (författare)
  • Correction for displacement artifacts in 3D phase contrast imaging
  • 2002
  • Ingår i: Journal of Magnetic Resonance Imaging. - Hoboken, USA : John Wiley & Sons. - 1053-1807 .- 1522-2586. ; 16:5, s. 591-597
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To correct for displacement artifacts in 3D phase contrast imaging.Materials and Methods: A 3D phase contrast pulse sequence was modified so that displacements of velocity measurements were restricted to one direction. By applying a postprocessing method, displaced measurements could be traced back to their accurate positions. Flow studies were performed using a phantom that generated flow through a stenosis, directed oblique relative to the phase and frequency encoding directions. Velocity profiles and streamline visualization were used to compare displaced and corrected velocity data to a reference.Results: Velocity profiles obtained from the original measurement showed skewed profiles due to the displacement artifact, both at close proximity to the orifice as well as further downstream. After correction, concordance with the reference improved considerably.Conclusion: The displacement artifact, which restricts the accuracy of phase contrast measurements, can be corrected for using the proposed method. Correction of the phase contrast velocity data may improve the accuracy of subsequent flow analysis and visualization.
  •  
5.
  • Viola, Federica, et al. (författare)
  • Data Quality and Optimal Background Correction Order of Respiratory-Gated k-Space Segmented Spoiled Gradient Echo (SGRE) and Echo Planar Imaging (EPI)-Based 4D Flow MRI
  • 2020
  • Ingår i: Journal of Magnetic Resonance Imaging. - : WILEY. - 1053-1807 .- 1522-2586. ; 51:3, s. 885-896
  • Tidskriftsartikel (refereegranskat)abstract
    • Background A reduction in scan time of 4D Flow MRI would facilitate clinical application. A recent study indicates that echo-planar imaging (EPI) 4D Flow MRI allows for a reduction in scan time and better data quality than the recommended k-space segmented spoiled gradient echo (SGRE) sequence. It was argued that the poor data quality of SGRE was related to the nonrecommended absence of respiratory motion compensation. However, data quality can also be affected by the background offset compensation. Purpose To compare the data quality of respiratory motion-compensated SGRE and EPI 4D Flow MRI and their dependence on background correction (BC) order. Study Type Retrospective. Subjects Eighteen healthy subjects (eight female, mean age 32 +/- 5 years). Field Strength and Sequence 5T. SGRE and EPI-based 4D Flow MRI. Assessment Data quality was investigated visually and by comparing flows through the cardiac valves and aorta. Measurements were obtained from transvalvular flow and pathline analysis. Statistical Tests Linear regression and Bland-Altman analysis were used. Wilcoxon test was used for comparison of visual scoring. Students t-test was used for comparison of flow volumes. Results No significant difference was found by visual inspection (P = 0.08). Left ventricular (LV) flows were strongly and very strongly associated with SGRE and EPI, respectively (R-2 = 0.86-0.94 SGRE; 0.71-0.79 EPI, BC0-4). LV and right ventricular (RV) outflows and LV pathline flows were very strongly associated (R-2 = 0.93-0.95 SGRE; 0.88-0.91 EPI, R-2 = 0.91-0.95 SGRE; 0.91-0.93 EPI, BC1-4). EPI LV outflow was lower than the short-axis-based stroke volume. EPI RV outflow and proximal descending aortic flow were lower than SGREs. Data Conclusion Both sequences yielded good internal data consistency when an adequate background correction was applied. Second and first BC order were considered sufficient for transvalvular flow analysis in SGRE and EPI, respectively. Higher BC orders were preferred for particle tracing. Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2019.
  •  
6.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy