SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "L773:1522 2586 ;pers:(Ekberg Olle)"

Search: L773:1522 2586 > Ekberg Olle

  • Result 1-3 of 3
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Diaz, Sandra, et al. (author)
  • Hyperpolarized (3)He apparent diffusion coefficient MRI of the lung: Reproducibility and volume dependency in healthy volunteers and patients with emphysema.
  • 2008
  • In: Journal of Magnetic Resonance Imaging. - : Wiley. - 1522-2586 .- 1053-1807. ; 27, s. 763-770
  • Journal article (peer-reviewed)abstract
    • PURPOSE: To measure the apparent diffusion coefficient (ADC) of hyperpolarized (HP) (3)He gas using diffusion weighted MRI in healthy volunteers and patients with emphysema and examine the reproducibility and volume dependency. MATERIALS AND METHODS: A total of eight healthy volunteers and 16 patients with emphysema were examined after inhalation of HP (3)He gas mixed with nitrogen (N(2)) during breathhold starting from functional residual capacity (FRC) in supine position. Coronal diffusion-sensitized MR images were acquired. Each subject was imaged on three separate days over a seven-day period and received two different volumes (6% and 15% of total lung capacity [TLC]) of HP (3)He each day. ADC maps and histograms were calculated. The mean and standard deviation (SD) of the ADC at different days and volumes were compared. RESULTS: The reproducibility of the mean ADC and SD over several days was good in both healthy volunteers and patients (SD range of 0.003-0.013 cm(2)/second and 0.001-0.009 cm(2)/second at 6% and 15% of TLC for healthy volunteers, and a SD range of 0.001-0.041 cm(2)/second and 0.001-0.011 cm(2)/second, respectively, for patients). A minor but significant increase in mean ADC with increased inhaled gas volume was observed in both groups. CONCLUSION: Mean ADC and SD of HP (3)He MRI is reproducible and discriminates well between healthy controls and patients with emphysema at the higher gas volume. This method is robust and may be useful to gain new insights into the pathophysiology and course of emphysema. J. Magn. Reson. Imaging 2008. (c) 2008 Wiley-Liss, Inc.
  •  
2.
  • Müller, Gunilla, et al. (author)
  • Assessment of perfusion in normal carpal bones with dynamic gadolinium-enhanced MRI at 3 tesla.
  • 2013
  • In: Journal of Magnetic Resonance Imaging. - : Wiley. - 1522-2586 .- 1053-1807. ; 38:1, s. 168-172
  • Journal article (peer-reviewed)abstract
    • PURPOSE: To investigate the normal enhancement patterns of the scaphoid, lunate, and capitate bones with dynamic contrast-enhanced magnetic resonance imaging (MRI). MATERIALS AND METHODS: The study was approved by the hospital's Ethics Committee. Nineteen volunteers (13 female, 6 male; mean age 38 years) were examined and all gave written consent. Perfusion was assessed at 3 Tesla using dynamic contrast-enhanced MRI. After two-dimensional (2D) motion correction of the data set, regions of interest were placed in the capitate, lunate, and distal and proximal pole of scaphoid bone and from the mean signal intensities (SI), the enhancement was computed. The four locations were compared for time to peak, delay time, maximum enhancement, and maximum slope using Friedman's two-way analysis of variance. RESULTS: Typical SI versus time curves revealed two components: a faster component with strong contrast enhancement and a slow component with prolonged enhancement. The mean value (standard deviation, SD) for maximum enhancement was 51 (33)% in the capitate, 54 (25)% in the lunate, 51 (34)% in the proximal pole and 51 (28)% in the distal pole of the scaphoid. The result of the Friedman test showed no significant difference (P < 0.05) in the perfusion variables between the capitate, lunate, and distal and proximal scaphoid bones. CONCLUSION: Assessment of perfusion in normal carpal bone using contrast-enhanced MRI is possible. Optimization of the method and understanding of the normal perfusion may allow evaluation of pathological conditions such as osteonecrosis. J. Magn. Reson. Imaging 2013;. © 2013 Wiley Periodicals, Inc.
  •  
3.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-3 of 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view