1.
  • Andersson, Thord, et al. (författare)
  • Consistent intensity inhomogeneity correction in water-fat MRI
  • 2015
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley-Blackwell. - 1053-1807 .- 1522-2586. ; 42:2
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To quantitatively and qualitatively evaluate the water-signal performance of the consistent intensity inhomogeneity correction (CIIC) method to correct for intensity inhomogeneitiesMETHODS: Water-fat volumes were acquired using 1.5 Tesla (T) and 3.0T symmetrically sampled 2-point Dixon three-dimensional MRI. Two datasets: (i) 10 muscle tissue regions of interest (ROIs) from 10 subjects acquired with both 1.5T and 3.0T whole-body MRI. (ii) Seven liver tissue ROIs from 36 patients imaged using 1.5T MRI at six time points after Gd-EOB-DTPA injection. The performance of CIIC was evaluated quantitatively by analyzing its impact on the dispersion and bias of the water image ROI intensities, and qualitatively using side-by-side image comparisons.RESULTS: CIIC significantly ( P1.5T≤2.3×10-4,P3.0T≤1.0×10-6) decreased the nonphysiological intensity variance while preserving the average intensity levels. The side-by-side comparisons showed improved intensity consistency ( Pint⁡≤10-6) while not introducing artifacts ( Part=0.024) nor changed appearances ( Papp≤10-6).CONCLUSION: CIIC improves the spatiotemporal intensity consistency in regions of a homogenous tissue type.
  •  
2.
  • Karlsson, Anette, et al. (författare)
  • Automatic and quantitative assessment of regional muscle volume by multi-atlas segmentation using whole-body water–fat MRI
  • 2015
  • Ingår i: Journal of Magnetic Resonance Imaging. - : John Wiley & Sons. - 1053-1807 .- 1522-2586. ; 41:6, s. 1558-1569
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeTo develop and demonstrate a rapid whole-body magnetic resonance imaging (MRI) method for automatic quantification of total and regional skeletal muscle volume.Materials and MethodsThe method was based on a multi-atlas segmentation of intensity corrected water–fat separated image volumes. Automatic lean muscle tissue segmentations were achieved by nonrigid registration of atlas datasets with 10 different manually segmented muscle groups. Ten subjects scanned at 1.5 T and 3.0 T were used as atlases, initial validation and optimization. Further validation used 11 subjects scanned at 3.0 T. The automated and manual segmentations were compared using intraclass correlation, true positive volume fractions, and delta volumes.ResultsFor the 1.5 T datasets, the intraclass correlation, true positive volume fractions (mean ± standard deviation, SD), and delta volumes (mean ± SD) were 0.99, 0.91 ± 0.02, −0.10 ± 0.70L (whole body), 0.99, 0.93 ± 0.02, 0.01 ± 0.07L (left anterior thigh), and 0.98, 0.80 ± 0.07, −0.08 ± 0.15L (left abdomen). The corresponding values at 3.0 T were 0.97, 0.92 ± 0.03, −0.17 ± 1.37L (whole body), 0.99, 0.93 ± 0.03, 0.03 ± 0.08L (left anterior thigh), and 0.89, 0.90 ± 0.04, −0.03 ± 0.42L (left abdomen). The validation datasets showed similar results.ConclusionThe method accurately quantified the whole-body skeletal muscle volume and the volume of separate muscle groups independent of field strength and image resolution. 
  •  
3.
  • Karlsson, Markus, et al. (författare)
  • Assessing Tissue Hydration Dynamics Based on Water/Fat Separated MRI
  • 2023
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 58:2, s. 652-660
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Optimal fluid status is an important issue in hemodialysis. Clinical evaluation of volume status and different diagnostic tools are used to determine hydration status in these patients. However, there is still no accurate method for this assessment. Purpose: To propose and evaluate relative lean water signal (LWSrel) as a water–fat MRI-based tissue hydration measurement. Study Type: Prospective. Population: A total of 16 healthy subjects (56 ± 6 years, 0 male) and 11 dialysis patients (60.3 ± 12.3 years, 9 male; dialysis time per week 15 ± 3.5 hours, dialysis duration 31.4 ± 27.9 months). Field Strength/Sequence: A 3 T; 3D spoiled gradient echo. Assessment: LWSrel, a measurement of the water concentration of tissue, was estimated from fat-referenced MR images. Segmentations of total adipose tissue as well as thigh and calf muscles were used to measure LWSrel and tissue volumes. LWSrel was compared between healthy subjects and dialysis patients, the latter before and after dialysis. Bioimpedance-based body composition monitor over hydration (BCM OH) was also measured. Statistical Tests: T-tests were used to compare differences between the healthy subjects and dialysis patients, as well as changes between before and after dialysis. Pearson correlation was calculated between MRI and non-MRI biomarkers. A P value <0.05 was considered statistically significant. Results: The LWSrel in adipose tissue was significantly higher in the dialysis cohort compared with the healthy cohort (246.8% ± 60.0% vs. 100.0% ± 10.8%) and decreased significantly after dialysis (246.8 ± 60.0% vs. 233.8 ± 63.4%). Thigh and calf muscle volumes also significantly decreased by 3.78% ± 1.73% and 2.02% ± 2.50% after dialysis. There was a significant correlation between changes in adipose tissue LWSrel and ultrafiltration volume (r = 87), as well as with BCM OH (r = 0.66). Data Conclusion: MRI-based LWSrel and tissue volume measurements are sensitive to tissue hydration changes occurring during dialysis. Evidence Level: 2. Technical Efficacy: Stage 3.
  •  
4.
  • Newman, David, et al. (författare)
  • Test–retest reliability of rapid whole body and compartmental fat volume quantification on a widebore 3T MR system in normal-weight, overweight, and obese subjects
  • 2016
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley-Blackwell. - 1053-1807 .- 1522-2586. ; 44:6, s. 1464-1473
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeTo measure the test–retest reliability of rapid (<15 min) whole body and visceral fat volume quantification in normal and obese subjects on a widebore 3T MR system and compare it with conventional manual segmentation.Materials and MethodsThirty participants (body mass index [BMI] 20.1–48.6 kg/m2) underwent two whole-body magnetic resonance imaging (MRI) examinations on a widebore 3T machine using a 2-point Dixon technique. Phase sensitive reconstruction and intensity inhomogeneity correction produced quantitative datasets of total adipose tissue (TAT), abdominal subcutaneous adipose tissue (ASAT), and visceral adipose tissue (VAT). The quantification was performed automatically using nonrigid atlas-based segmentation and compared with manual segmentation (SliceOmatic).ResultsThe mean TAT was 31.74 L with a coefficient of variation (CV) of 0.79% and a coefficient of repeatability (CR) of 0.49 L. The ASAT was 7.92 L with a CV of 2.98% and a CR of 0.46 L. There was no significant difference in the semiautomated and manually segmented VAT (P = 0.73) but there were differences in the reliability of the two techniques. The mean semiautomated VAT was 2.56 L, CV 1.8%, and CR 0.09 L compared to the mean manually segmented VAT of 3.12 L, where the CV was 6.3% and the CR was 0.39 L.ConclusionRapid semiautomated whole body and compartmental fat volume quantification can be derived from a widebore 3T system, for a range of body sizes including obese patients, with “almost perfect” test–retest reliability.
  •  
5.
  • Peterson, Pernilla, et al. (författare)
  • Fat Quantification in Skeletal Muscle Using Multigradient-Echo Imaging: Comparison of Fat and Water References
  • 2016
  • Ingår i: Journal of Magnetic Resonance Imaging. - : WILEY-BLACKWELL. - 1053-1807 .- 1522-2586. ; 43:1, s. 203-212
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To investigate the precision, accuracy, and repeatability of water/fat imaging-based fat quantification in muscle tissue using a large flip angle (FA) and a fat reference for the calculation of the proton density fat fraction (FF). Comparison is made to a small FA water reference approach. Materials and Methods: An Intralipid phantom and both forearms of six patients suffering from lymphedema and 10 healthy volunteers were investigated at 1.5T. Two multigradient-echo sequences with eight echo times and FAs of 10 degrees and 85 degrees were acquired. For healthy volunteers, the acquisition of the right arm was performed twice with repositioning. From each set, water reference FF and fat reference FF images were reconstructed and the average FF and the standard deviation were calculated within the subfascial compartment. The small FA water reference was considered the reference standard. Results: A high agreement was found between the small FA water reference and large FA fat reference methods (FF bias=0.31%). In this study, the large FA fat reference approach also resulted in higher precision (38% smaller FF standard deviation in homogenous muscle tissue), but no significant difference in repeatability between the various methods was detected (coefficient of repeatability of small FA water reference approach 0.41%). Conclusion: The precision of fat quantification in muscle tissue can be increased with maintained accuracy using a larger flip angle, if a fat reference instead of a water reference is used.
  •  
6.
  • Romu, Thobias, et al. (författare)
  • Characterization of Brown Adipose Tissue by Water-Fat Separated Magnetic Resonance Imaging
  • 2015
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 42:6, s. 1639-1645
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: To evaluate the possibility of quantifying brown adipose tissue (BAT) volume and fat concentration with a high resolution, long echo time, dual-echo Dixon imaging protocol. Methods: A 0.42 mm isotropic resolution water-fat separated MRI protocol was implemented by using the second opposite-phase echo and third in-phase echo. Fat images were calibrated with regard to the intensity of nearby white adipose tissue (WAT) to form relative fat content (RFC) images. To evaluate the ability to measure BAT volume and RFC contrast dynamics, rats were divided into two groups that were kept at 48 or 22 degrees C for 5 days. The rats were then scanned in a 70 cm bore 3.0 Tesla MRI scanner and a human dual energy CT. Interscapular, paraaortal, and perirenal BAT (i/pa/pr-BAT) depots as well as WAT and muscle were segmented in the MRI and CT images. Biopsies were collected from the identified BAT depots. Results: The biopsies confirmed that the three depots identified with the RFC images consisted of BAT. There was a significant linear correlation (P< 0.001) between the measured RFC and the Hounsfield units from DECT. Significantly lower iBAT RFC (P=0.0064) and significantly larger iBAT and prBAT volumes (P=0.0017) were observed in the cold stimulated rats. Conclusion: The calibrated Dixon images with RFC scaling can depict BAT and be used to measure differences in volume, and fat concentration, induced by cold stimulation. The high correlation between RFC and HU suggests that the fat concentration is the main RFC image contrast mechanism.
  •  