  • Tidskriftsartikel (refereegranskat)abstract
    • Endovascular treatment of stroke, although highly effective, may fail to reach complete recanalization in around 20% of cases. The Advanced Thrombectomy System (ANCD) is a novel stroke thrombectomy device designed to reduce clot fragmentation and facilitate retrieval by inducing local flow arrest and allowing distal aspiration in combination with a stent retriever. We aimed to assess the preclinical efficacy of ANCD.MethodsSoft red blood cell (RBC)-rich (n=20/group) and sticky fibrin-rich (n=30/group) clots were used to create middle cerebral artery (MCA) occlusions in two vascular phantoms. Three different treatment strategies were tested: (1) balloon guide catheter + Solitaire (BGC+SR); (2) distal access catheter + SR (DAC+SR); and (3) ANCD+SR, until complete recanalization was achieved or to a maximum of three passes. The recanalization rate was determined after each pass.ResultsAfter one pass, ANCD+SR resulted in an increased recanalization rate (94%) for all clots together compared with BGC+SR (66%; p<0.01) or DAC+SR (80%; p=0.04). After the final pass the recanalization rate increased in all three groups but remained higher with ANCD+SR (100%) than with BGC+SR (74%; p<0.01) or DAC+SR (90%; p=0.02). The mean number of passes was lower with ANCD+SR (1.06) than with BGC+SR (1.46) or DAC+SR (1.25) (p=0.01). A logistic regression model adjusted for treatment arm, clot type, and model used showed that both RBC-rich clots (OR 8.1, 95% CI 1.6 to 13.5) and ANCD+SR (OR 3.9, 95% CI 1.01 to 15.8) were independent predictors of first-pass recanalization.ConclusionIn in vitro three-dimensional models replicating MCA-M1 occlusion, ANCD+SR showed significantly better recanalization rates in fewer passes than other commonly used combinations of devices.
  •  
2.
  • Sanchez, S, et al. (författare)
  • Preclinical evaluation of the ANCD thrombectomy device: safety and efficacy in a swine clot model
  • 2020
  • Ingår i: Journal of neurointerventional surgery. - : BMJ. - 1759-8486 .- 1759-8478. ; 12:10, s. 1008-1013
  • Tidskriftsartikel (refereegranskat)abstract
    • The Advanced Thrombectomy System (ANCD) provides a new funnel component designed to reduce clot fragmentation and facilitate retrieval in patients with stroke by locally restricting flow, allowing distal aspiration in combination with a stent retriever (SR).ObjectiveTo evaluate the preclinical efficacy and safety of the ANCD in a swine clot model.MethodsSoft and firm clots were implanted in the lingual and cervical arteries of 11 swine to obtain Thrombolysis in Cerebral Infarction (TICI) 0 blood flow. Mechanical thrombectomy was performed with either a balloon guide catheter+Solitaire 2 stent retriever (BGC+SR, n=13) or ANCD+SR (n=13). TICI flow was evaluated and successful revascularization was defined as TICI 3 (normal perfusion). To characterize safety, a total of 3 passes were performed in each vessel independent of recanalization. Tissues were explanted for histopathological analysis after 3 and 30 days, respectively.ResultsFirst pass reperfusion rates were ANCD+SR: 69% and BGC+SR: 46%. Reperfusion increased after the third pass in both groups (ANCD+SR: 100%, vs BGC+SR: 77%). Recanalization was achieved after an average of 1.4 and 1.9 passes in ANCD+SR and BGC+SR (p=0.095), respectively. Vessel injury was comparable in both groups; endothelial loss at 3 days was the most common injury seen (ANCD+SR: 1.78±1.22; BGC+SR: 2.03±1.20; p=0.73), while other histopathological markers were absent or minimal. Tissues downstream from targeted vessels also showed absence or minimal lesions across both groups.ConclusionsResults in a swine clot model support the high efficacy of the ANCD+SR without causing clinically significant vessel injury potentially related to the new funnel component.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Ribo, M. (2)
Andersson, T. (2)
Sanchez, S. (2)
Villanova, H (2)
Galve, I (2)
visa fler...
Rios, A. (2)
Jovin, T. (1)
Cognard, C (1)
Bailey, L (1)
Cortinas, I (1)
Ducore, R (1)
visa färre...
Lärosäte
Karolinska Institutet (2)
Språk
Engelska (2)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy