SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1873 1449 ;lar1:(ki)"

Sökning: L773:1873 1449 > Karolinska Institutet

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Dohlmar, Frida, et al. (författare)
  • Validation of automated post-adjustments of HDR prostate brachytherapy treatment plans by quantitative measures and oncologist observer study
  • 2023
  • Ingår i: Brachytherapy. - : Elsevier BV. - 1538-4721 .- 1873-1449. ; 22:3, s. 407-415
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: The aim was to evaluate a postprocessing optimization algorithm's ability to improve the spatial properties of a clinical treatment plan while preserving the target coverage and the dose to the organs at risk. The goal was to obtain a more homogenous treatment plan, minimizing the need for manual adjustments after inverse treatment planning. MATERIALS AND METHODS: The study included 25 previously treated prostate cancer pa-tients. The treatment plans were evaluated on dose-volume histogram parameters established clin-ical and quantitative measures of the high dose volumes. The volumes of the four largest hot spots were compared and complemented with a human observer study with visual grading by eight oncologists. Statistical analysis was done using ordinal logistic regression. Weighted kappa and Fleiss' kappa were used to evaluate intra-and interobserver reliability. RESULTS: The quantitative analysis showed that there was no change in planning target volume (PTV) coverage and dose to the rectum. There were significant improvements for the adjusted treatment plan in: V150% and V200% for PTV, dose to urethra, conformal index, and dose nonhomogeneity ratio. The three largest hot spots for the adjusted treatment plan were significantly smaller compared to the clinical treatment plan. The observers preferred the adjusted treatment plan in 132 cases and the clinical in 83 cases. The observers preferred the adjusted treatment plan on homogeneity and organs at risk but preferred the clinical plan on PTV coverage. CONCLUSIONS: Quantitative analysis showed that the postadjustment optimization tool could improve the spatial properties of the treatment plans while maintaining the target coverage.
  •  
2.
  •  
3.
  •  
4.
  • Karlsson, Mattias, et al. (författare)
  • Monte Carlo dosimetry of the eye plaque design used at the St. Erik Eye Hospital for I-125 brachytherapy
  • 2014
  • Ingår i: Brachytherapy. - : Elsevier. - 1538-4721 .- 1873-1449. ; 13:6, s. 651-656
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: At St. Erik Eye Hospital in Stockholm, Sweden, ocular tumors of apical height above 6 mm are treated with brachytherapy, using iodine-125 seeds attached to a gold alloy plaque while the treatment planning is performed assuming homogeneous water surroundings. The aim of this work was to investigate the dose-modifying effects of the plaque and the seed fixating silicone rubber glue. METHODS AND MATERIALS: The impact of the gold plaque and silicone rubber glue was studied with the Monte Carlo N-particle transport code, version 5. RESULTS: For the 2 cm most proximal to the plaque surface along the plaques central axis, the eyeball received 104.6-93.0% of the dose in all-water conditions. CONCLUSIONS: The 0.3 mm thick layer of silicone rubber glue, used for seed fixation, attenuates photons little enough to allow characteristic X-rays from the gold alloy plaque to reach the eyeball. Close to the plaque, the dose rates were higher with the plaque and glue present, than in homogeneous water conditions. This is in contrast to what has been reported for more commonly used eye plaques, demonstrating the importance of investigating the dosimetry of individual treatment systems.
  •  
5.
  • Persson, Maria, et al. (författare)
  • Experience of using MOSFET detectors for dose verification measurements in an end-to-end Ir-192 brachytherapy quality assurance system
  • 2018
  • Ingår i: Brachytherapy. - : ELSEVIER SCIENCE INC. - 1538-4721 .- 1873-1449. ; 17:1, s. 227-233
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: Establishment of an end-to-end system for the brachytherapy (BT) dosimetric chain could be valuable in clinical quality assurance. Here, the development of such a system using MOSFET (metal oxide semiconductor field effect transistor) detectors and experience gained during 2 years of use are reported with focus on the performance of the MOSFET detectors. METHODS AND MATERIALS: A bolus phantom was constructed with two implants, mimicking prostate and head amp; neck treatments, using steel needles and plastic catheters to guide the Ir-192 source and house the MOSFET detectors. The phantom was taken through the BT treatment chain from image acquisition to dose evaluation. During the 2-year evaluation-period, delivered doses were verified a total of 56 times using MOSFET detectors which had been calibrated in an external Co-60 beam. An initial experimental investigation on beam quality differences between Ir-192 and Co-60 is reported. RESULTS: The standard deviation in repeated MOSFET measurements was below 3% in the six measurement points with dose levels above 2 Gy. MOSFET measurements overestimated treatment planning system doses by 2-7%. Distance-dependent experimental beam quality correction factors derived in a phantom of similar size as that used for end-to-end tests applied on a time-resolved measurement improved the agreement. CONCLUSIONS: MOSFET detectors provide values stable over time and function well for use as detectors for end-to-end quality assurance purposes in 192Ir BT. Beam quality correction factors should address not only distance from source but also phantom dimensions. (C) 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
  •  
6.
  •  
7.
  • Wahlberg, Karin, et al. (författare)
  • Maternal polymorphisms in glutathione-related genes are associated with maternal mercury concentrations and early child neurodevelopment in a population with a fish-rich diet
  • 2018
  • Ingår i: Environment International. - : Elsevier BV. - 0160-4120 .- 1873-6750. ; 115, s. 142-149
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Glutathione (GSH) pathways play a key role the metabolism and elimination of the neurotoxicant methylmercury (MeHg). We hypothesized that maternal genetic variation linked to GSH pathways could influence MeHg concentrations in pregnant mothers and children and thereby also affect early life development. Methods: The GCLM (rs41303970, C/T), GCLC (rs761142, T/G) and GSTP1 (rs1695, A/G) polymorphisms were genotyped in 1449 mothers in a prospective study of the Seychellois population with a diet rich in fish. Genotypes were analyzed in association with maternal hair and blood Hg, fetal blood Hg (cord blood Hg), as well as children's mental (MDI) and motor development (PDI; MDI and PDI assessed by Bayley Scales of Infant Development at 20 months). We also examined whether genotypes modified the association between Hg exposure and developmental outcomes. Results: GCLC rs761142 TT homozygotes showed statistically higher mean maternal hair Hg (4.12 ppm) than G carriers (AG 3.73 and GG 3.52 ppm) (p = 0.037). For the combination of GCLC rs761142 and GCLM rs41303970, double homozygotes TT + CC showed higher hair Hg (4.40 ppm) than G + T carriers (3.44 ppm; p = 0.018). No associations were observed between GSTP1 rs1695 and maternal hair Hg or between any genotypes and maternal blood Hg or cord blood Hg. The maternal GSTP1 rs1695 rare allele (G) was associated with a lower MDI among children (β = −1.48, p = 0.048). We also observed some interactions: increasing Hg in maternal and cord blood was associated with lower PDI among GCLC rs761142 TT carriers; and increasing Hg in hair was associated with lower MDI among GSTP1 rs1695 GG carriers. Conclusions: Maternal genetic variation in genes involved in GSH synthesis is statistically associated with Hg concentrations in maternal hair, but not in maternal or fetal blood. We observed interactions that suggest maternal GSH genetics may modify associations between MeHg exposure and neurodevelopmental outcomes.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy