SwePub
Sök i LIBRIS databas

  Extended search

L773:1873 1449
 

Search: L773:1873 1449 > Persson Maria > Experience of using...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Experience of using MOSFET detectors for dose verification measurements in an end-to-end Ir-192 brachytherapy quality assurance system

Persson, Maria (author)
Karolinska Univ Hosp, Sweden
Nilsson, Josef (author)
Karolinska Univ Hosp, Sweden
Carlsson Tedgren, Åsa (author)
Karolinska Institutet,Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Radiofysikavdelningen US,Karolinska Univ Hosp, Sweden
 (creator_code:org_t)
ELSEVIER SCIENCE INC, 2018
2018
English.
In: Brachytherapy. - : ELSEVIER SCIENCE INC. - 1538-4721 .- 1873-1449. ; 17:1, s. 227-233
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • PURPOSE: Establishment of an end-to-end system for the brachytherapy (BT) dosimetric chain could be valuable in clinical quality assurance. Here, the development of such a system using MOSFET (metal oxide semiconductor field effect transistor) detectors and experience gained during 2 years of use are reported with focus on the performance of the MOSFET detectors. METHODS AND MATERIALS: A bolus phantom was constructed with two implants, mimicking prostate and head amp; neck treatments, using steel needles and plastic catheters to guide the Ir-192 source and house the MOSFET detectors. The phantom was taken through the BT treatment chain from image acquisition to dose evaluation. During the 2-year evaluation-period, delivered doses were verified a total of 56 times using MOSFET detectors which had been calibrated in an external Co-60 beam. An initial experimental investigation on beam quality differences between Ir-192 and Co-60 is reported. RESULTS: The standard deviation in repeated MOSFET measurements was below 3% in the six measurement points with dose levels above 2 Gy. MOSFET measurements overestimated treatment planning system doses by 2-7%. Distance-dependent experimental beam quality correction factors derived in a phantom of similar size as that used for end-to-end tests applied on a time-resolved measurement improved the agreement. CONCLUSIONS: MOSFET detectors provide values stable over time and function well for use as detectors for end-to-end quality assurance purposes in 192Ir BT. Beam quality correction factors should address not only distance from source but also phantom dimensions. (C) 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Brachytherapy; Quality assurance; End-to-end; 192Ir; MOSFET

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Persson, Maria
Nilsson, Josef
Carlsson Tedgren ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Brachytherapy
By the university
Linköping University
Karolinska Institutet

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view