SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1969 6213 ;pers:(Grimfjärd Per)"

Sökning: L773:1969 6213 > Grimfjärd Per

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Buccheri, Sergio, et al. (författare)
  • Clinical outcomes with unselected use of an ultrathin-strut sirolimus-eluting stent : a report from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR)
  • 2021
  • Ingår i: EuroIntervention. - : European Society of Cardiology. - 1774-024X .- 1969-6213. ; 16:17, s. 1413-1421
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: The aim of this study was to assess the real-world clinical performance of a sirolimus-eluting ultrathin-strut drug-eluting stent (DES) (Orsiro) in a large nationwide cohort of patients undergoing percu-taneous coronary intervention (PCI).Methods and results: From the Swedish Coronary Angiography and Angioplasty Registry, the two-year outcomes of 4,561 patients implanted with Orsiro (Orsiro group) and 69,570 receiving other newer-gen-eration DES (n-DES group) were analysed. The rate of definite stent thrombosis was low in both groups (0.67% and 0.83% for Orsiro and n-DES, respectively; adjusted hazard ratio [HR] 0.90, 95% confidence interval [CI]: 0.55-1.46, p-value 0.66). Restenosis was also infrequent (1.5% vs 2.0% with Orsiro and n-DES, adjusted HR 0.81, 95% CI: 0.63-1.03, p-value=0.09). The risk of target lesion revascularisation by PCI was lower in the Orsiro group (1.6% vs 2.3%, adjusted HR 0.75, 95% CI: 0.60-0.94, p-value=0.013). All-cause mortality and myocardial infarction did not show a statistically significant difference between the two groups (mortality of 7.5% in both groups, adjusted HR 0.99, 95% CI: 0.72-1.35, p-value=0.94; 6.0% vs 5.2% for myocardial infarction, adjusted HR 1.19, 95% CI: 1.00-1.43, p-value=0.06).Conclusions: In a nationwide scenario, the use of a sirolimus-eluting ultrathin-strut DES portended favourable clinical outcomes.
  •  
2.
  • Grimfjärd, Per, et al. (författare)
  • Outcome of percutaneous coronary intervention with the Absorb bioresorbable scaffold : Data from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR)
  • 2017
  • Ingår i: EuroIntervention. - 1774-024X .- 1969-6213. ; 13:11, s. 1304-1311
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Randomised trials indicate higher rates of stent thrombosis (ST) and target lesion failure (TLF) after percutaneous coronary intervention (PCI) with the Absorb bioresorbable scaffold (BRS) compared with modern drug-eluting stents (DES). We aimed to investigate the outcome of all Swedish patients treated with the Absorb BRS. Methods and results: The Absorb BRS (n=810) was compared with commonly used modern DES (n=67,909). The main outcome measure was definite ST; mean follow-up was two years. Despite being implanted in a younger, lower-risk population compared with modern DES, the Absorb BRS was associated with a higher crude incidence of definite ST at stent level: 1.5 vs. 0.6%, hazard ratio (HR) 2.38 (95% confidence interval [CI]: 1.34-4.23), adjusted HR 4.34 (95% CI: 2.37-7.94); p<0.001. The patient level adjusted HR was 4.44 (95% CI: 2.25-8.77). Rates of in-stent restenosis were similar for BRS and DES. Non-compliance with dual antiplatelet therapy (DAPT) guidelines was noted in six out of 12 BRS ST events. Three very late ST events occurred with the Absorb BRS. Conclusions: In this real-world observational study, the Absorb BRS was associated with a significantly higher risk of definite ST compared with modern DES. Non-compliance with DAPT guideline recommendations was common among Absorb definite ST events.
  •  
3.
  • Grimfjärd, Per, et al. (författare)
  • Unfractionated heparin versus bivalirudin in patients undergoing primary percutaneous coronary intervention : a SWEDEHEART study
  • 2017
  • Ingår i: EuroIntervention. - 1774-024X .- 1969-6213. ; 12:16, s. 2009-2017
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: The aim of the stud was to compare outcomes in unfractionated heparin (UM) and bivalirudintreated patients undergoing primary percutaneous coronary intervention (PPCI). Methods and results: This observational study contained 20,612 PPCT patients treated with either GM monotherapv or bivalirudin with or without concomitant UFE. Patients with oral anticoagulant or glycoprotein IIb/IIIa inhibitor (GPI) treatment were excluded. The primary outcome measure was definite early stent thrombosis (Si) that occurred at low and similar rates in UNA only and bivalirudin-treated patients: 0.9% vs. 0.8% (adjusted hazard ratio [HR] 1.08, 95% confidence interval [CI]: 0.7-1.65). All-cause death at 30 days occurred in 6.9% vs. 5.4% of patients (adjusted HR 1.23, 95% Cl: 1.05-1.44) and within 365 days in 12.1% vs. 8.9% (adjusted HR 1.34, 95% CI: 1.19-1.52) in the two groups, respectively. The incidence of major bleeding within 30 days was 0.8% vs. 0.6% (adjusted HR 1.54, 95% CI: 0.97-2.45). The incidence of reinfarction within 365 days and stroke within 30 days was similar between groups. Conclusions: In this large, nationwide observational study we found low and similar rates of early ST in UFH only and bivalirudin-treated patients undergoing primary PCI. Mortality was higher in IJFH compared with bivalirudin-treated patients.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy