1.
  • Persson, M, et al. (författare)
  • Wound ventilation with ultraclean air for prevention of direct airborne contamination during surgery
  • 2004
  • Ingår i: Infection control and hospital epidemiology. - : Cambridge University Press (CUP). - 0899-823X .- 1559-6834. ; 25:4, s. 297-301
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Objective:Despite the novelties in operating room ventilation, airborne bacteria remain an important source of surgical wound contamination. An ultraclean airflow from the ceiling downward may convey airborne particles from the surgical team into the wound, thus increasing the risk of infection. Therefore, similar ventilation from the wound upward should be considered. We investigated the effect of wound ventilation on the concentration of airborne particles in a wound model during simulated surgery.Design:Randomized experimental study simulating surgery with a wound cavity model.Setting:An operating room of a university hospital ventilated with ultraclean air directed downward.Interventions:Particles 5 um and larger were counted with and without a 5-cm deep cavity and with and with-out the insufflation of ultraclean air.Results:With the surgeon standing upright, no airborne particles could be detected in the wound model. In contrast, during simulated operations, the median number of particles per 0.1 cu ft reached 18 (25th and 75th percentiles, 12 and 22.25) in the model with a cavity and 15.5 (25th and 75th percentiles, 14 and 21.5) without. With a cavity, wound ventilation markedly reduced the median number of particles to 1 (range, 0 to 1.25;P< .001).Conclusions:To protect a surgical wound against direct airborne contamination, air should be directed away from the wound rather than toward it. This study provides supportive evidence to earlier studies that operating room ventilation with ultraclean air is imperfect during surgical activity and that wound ventilation may be a simple complement. Further clinical trials are needed.
  •  
2.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Persson, M (1)
Walder, Mats (1)
Odenholt, Inga (1)
van der Linden, J (1)
Wullt, Marlene (1)
Lärosäte
Lunds universitet (1)
Karolinska Institutet (1)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy