SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

L773:1051 8223
 

Sökning: L773:1051 8223 > Göteborgs universitet > (2015) > High-Tc SQUID vs. l...

High-Tc SQUID vs. low-Tc SQUID-based recordings on a head phantom: Benchmarking for magnetoencephalography

Xie, Minshu, 1988 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Schneiderman, Justin, 1979 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi,Institute of Neuroscience and Physiology
Chukharkin Leonidovich, Maxim, 1980 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Kalaboukhov, Alexei, 1975 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Whitmarsh, S. (författare)
Karolinska Institutet
Lundqvist, D. (författare)
Karolinska Institutet
Winkler, Dag, 1957 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
2015
2015
Engelska.
Ingår i: IEEE Transactions on Applied Superconductivity. - 1558-2515 .- 1051-8223. ; 25:3, s. Article number 6940248-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We explore the potential that high critical-temperature (high-Tc) superconducting quantum interference device (SQUID) technology has for magnetic recordings of brain activity, i.e., magnetoencephalography (MEG). To this end, we performed a series of benchmarking experiments to directly compare recordings with a commercial (low-Tc SQUID-based) 306-channel MEG system (Elekta Neuromag TRIUX, courtesy of NatMEG) and a single channel high-Tc SQUID system. The source on which we recorded is a head phantom including 32 artificial current dipoles housed inside a half-spherical shell (courtesy Elekta Oy) for calibrating MEG systems. The high-Tc SQUID magnetometer consisted of a single layer YBa2Cu3O7-x (YBCO) film on a 10 mm × 10 mm bicrystal substrate with a magnetic field sensitivity of ~40 fT/Hz down to 10 Hz. We recorded serial activations of eight tangential current dipoles located at different depths from the surface of the head phantom. Results indicate that our individual high-Tc SQUID demonstrated signal-to-noise ratios (SNRs) about 7-14 times lower than that of similarly-positioned low-Tc SQUIDs in a commercial MEG system. Only considering single-channel SNR, high-Tc SQUIDs with resolution better than 18 fT/Hz would be required to outperform the low-Tc system for shallow dipole sources. This work demonstrates a proof of principle study for future multichannel high-Tc MEG system development.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Nanoteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Nano-technology (hsv//eng)

Nyckelord

High-temperature superconductors
Benchmark testing
Yttrium barium copper oxide
dc-SQUIDs
Magnetoencephalography
Benchmark testing; dc-SQUIDs; High-temperature superconductors; Magnetoencephalography; Yttrium barium copper oxide

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy