SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1873 1449 srt2:(2015-2019);srt2:(2018)"

Sökning: L773:1873 1449 > (2015-2019) > (2018)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Persson, Maria, et al. (författare)
  • Experience of using MOSFET detectors for dose verification measurements in an end-to-end Ir-192 brachytherapy quality assurance system
  • 2018
  • Ingår i: Brachytherapy. - : ELSEVIER SCIENCE INC. - 1538-4721 .- 1873-1449. ; 17:1, s. 227-233
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: Establishment of an end-to-end system for the brachytherapy (BT) dosimetric chain could be valuable in clinical quality assurance. Here, the development of such a system using MOSFET (metal oxide semiconductor field effect transistor) detectors and experience gained during 2 years of use are reported with focus on the performance of the MOSFET detectors. METHODS AND MATERIALS: A bolus phantom was constructed with two implants, mimicking prostate and head amp; neck treatments, using steel needles and plastic catheters to guide the Ir-192 source and house the MOSFET detectors. The phantom was taken through the BT treatment chain from image acquisition to dose evaluation. During the 2-year evaluation-period, delivered doses were verified a total of 56 times using MOSFET detectors which had been calibrated in an external Co-60 beam. An initial experimental investigation on beam quality differences between Ir-192 and Co-60 is reported. RESULTS: The standard deviation in repeated MOSFET measurements was below 3% in the six measurement points with dose levels above 2 Gy. MOSFET measurements overestimated treatment planning system doses by 2-7%. Distance-dependent experimental beam quality correction factors derived in a phantom of similar size as that used for end-to-end tests applied on a time-resolved measurement improved the agreement. CONCLUSIONS: MOSFET detectors provide values stable over time and function well for use as detectors for end-to-end quality assurance purposes in 192Ir BT. Beam quality correction factors should address not only distance from source but also phantom dimensions. (C) 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
  •  
2.
  • Wahlberg, Karin, et al. (författare)
  • Maternal polymorphisms in glutathione-related genes are associated with maternal mercury concentrations and early child neurodevelopment in a population with a fish-rich diet
  • 2018
  • Ingår i: Environment International. - : Elsevier BV. - 0160-4120 .- 1873-6750. ; 115, s. 142-149
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Glutathione (GSH) pathways play a key role the metabolism and elimination of the neurotoxicant methylmercury (MeHg). We hypothesized that maternal genetic variation linked to GSH pathways could influence MeHg concentrations in pregnant mothers and children and thereby also affect early life development. Methods: The GCLM (rs41303970, C/T), GCLC (rs761142, T/G) and GSTP1 (rs1695, A/G) polymorphisms were genotyped in 1449 mothers in a prospective study of the Seychellois population with a diet rich in fish. Genotypes were analyzed in association with maternal hair and blood Hg, fetal blood Hg (cord blood Hg), as well as children's mental (MDI) and motor development (PDI; MDI and PDI assessed by Bayley Scales of Infant Development at 20 months). We also examined whether genotypes modified the association between Hg exposure and developmental outcomes. Results: GCLC rs761142 TT homozygotes showed statistically higher mean maternal hair Hg (4.12 ppm) than G carriers (AG 3.73 and GG 3.52 ppm) (p = 0.037). For the combination of GCLC rs761142 and GCLM rs41303970, double homozygotes TT + CC showed higher hair Hg (4.40 ppm) than G + T carriers (3.44 ppm; p = 0.018). No associations were observed between GSTP1 rs1695 and maternal hair Hg or between any genotypes and maternal blood Hg or cord blood Hg. The maternal GSTP1 rs1695 rare allele (G) was associated with a lower MDI among children (β = −1.48, p = 0.048). We also observed some interactions: increasing Hg in maternal and cord blood was associated with lower PDI among GCLC rs761142 TT carriers; and increasing Hg in hair was associated with lower MDI among GSTP1 rs1695 GG carriers. Conclusions: Maternal genetic variation in genes involved in GSH synthesis is statistically associated with Hg concentrations in maternal hair, but not in maternal or fetal blood. We observed interactions that suggest maternal GSH genetics may modify associations between MeHg exposure and neurodevelopmental outcomes.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy