  • Bongiorni, Maria Grazia, et al. (författare)
  • Current practice in transvenous lead extraction : a European Heart Rhythm Association EP Network Survey
  • 2012
  • Ingår i: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 14:6, s. 783-786
  • Tidskriftsartikel (refereegranskat)abstract
    • AIM: Current practice with regard to transvenous lead extraction among European implanting centres was analysed by this survey. METHODS AND RESULTS: Among all contacted centres, 164, from 30 countries, declared that they perform transvenous lead extraction and answered 58 questions with a compliance rate of 99.9%. Data from the survey show that there seems to be an overall increasing experience of managing various techniques of lead extraction and a widespread involvement of cardiac centres in this treatment. Results and complication rates seem comparable with those of main international registries. CONCLUSION: This survey gives an interesting snapshot of lead extraction in Europe today and gives some clues for future research and prospective European registries.
  •  
2.
  • Bongiorni, Maria Grazia, et al. (författare)
  • ELECTRa (European Lead Extraction ConTRolled) Registry-Shedding light on transvenous lead extraction real-world practice in Europe
  • 2013
  • Ingår i: Herzschrittmachertherapie & Elektrophysiologie. - : Springer Science and Business Media LLC. - 0938-7412 .- 1435-1544. ; 24:3, s. 171-175
  • Tidskriftsartikel (refereegranskat)abstract
    • With the growing recognition of the clinical need and wider indications for cardiovascular implantable electronic devices (CIED), the number of implant procedures has increased considerably. Consequently, the rate of complications related to these devices has also increased. Transvenous lead extraction (TLE) is the gold standard in the treatment of CIED-related infective complications and is often required in the management of lead malfunction. An increasing number of centers currently perform TLE procedures. The ELECTRa (European Lead Extraction ConTRolled) Registry is the first large prospective multicenter registry of consecutive patients undergoing TLE in Europe, conducted by the European Heart Rhythm Association (EHRA) and managed by the European Society of Cardiology (ESC) EURObservational Research Department. The primary objective of the registry is to evaluate the acute and long-term safety of TLE; the secondary objective is to describe the characteristics of the patients, the leads, the indications for TLE, and the tools and techniques currently used for TLE. About 100 centers will be enrolled on a voluntary basis from European countries; they are anonymous and stratified on the basis of their volume of activity into high-volume centers (> 30 patients/year) and low-volume centers: (≤ 30 patients/year). Each participating center will have to enroll and follow up for 1 year consecutively assessed patients undergoing TLE from November 2012 to January 2014. The target is to achieve a sample size of at least 3,500 patients for statistical analysis. Data will be collected using a Web-based system and will be audited at randomly selected centers. The official start was on 6 November. Eighty-nine centers have joined so far, 65 centers are currently active, those who have already obtained the approval of their own ethics committee, and 1,099 patients were enrolled at the end of June 2013. The independence of the registry, the consecutiveness of the patient enrolment, and the monitoring of the study are characteristics of this registry that will contribute to the scientific validity of the objectives to be achieved.
  •  
3.
  • Bongiorni, Maria Grazia, et al. (författare)
  • The European Lead Extraction ConTRolled (ELECTRa) study : a European Heart Rhythm Association (EHRA) Registry of Transvenous Lead Extraction Outcomes
  • 2017
  • Ingår i: European Heart Journal. - : OXFORD UNIV PRESS. - 0195-668X .- 1522-9645. ; 38:40, s. 2995-3005
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims The European Lead Extraction ConTRolled Registry (ELECTRa), is a prospective registry of consecutive transvenous lead extraction (TLE) procedures conducted by the European Heart Rhythm Association (EHRA) in order to identify the safety and efficacy of the current practice of TLE Methods and results European centres performing TLE, invited by the organizing committee on behalf of EHRA, prospectively recruited all consecutive patients undergoing TLE at their institution. The primary endpoint was TLE safety defined by pre-discharge major procedure-related complications including death. Secondary endpoints included clinical and radiological success and overall complication rates. Outcomes were compared between Low Volume (LoV) vs. High Volume (HiV) centers (LoV < 30 and HiV >= 30 procedures/year). A total of 3555 consecutive patients (pts) of whom 3510 underwent TLE at 73 centres in 19 European countries were enrolled between November 2012 and May 2014. The primary endpoint of in-hospital procedure-related major complication rate was 1.7% [95% CI 1.3-2.1%] (58/3510 pts) including a mortality of 0.5% [95% CI 0.3-0.8%] (17/3510 pts). Approximately two-thirds (37/58) of these complications occurred during the procedure and one-third (21/58) in the post-operative period. The most common procedure related complications were those requiring pericardiocentesis or chest tube and/or surgical repair (1.4% [95% CI 1.0-1.8%]). Complete clinical and radiological success rates were 96.7% [95% CI 96.1-97.3%] and 95.7% [95% CI 95.2-96.2%], respectively. The all cause in-hospital major complications and deaths were significantly lower in HiV centres vs. LoV centres (2.4% [95% CI 1.9-3.0%] vs. 4.1% [95% CI 2.7-6.0%], P = 0.0146; and 1.2% [95% CI 0.8-1.6%] vs. 2.5% [95% CI 1.5-4.1%] P = 0.0088), although those related to the procedure did not reach statistical significance. Radiological and clinical successes were more frequent in HiV vs. LoV centres. Conclusion The ELECTRa study is the largest prospective registry on TLE and confirmed the safety and efficacy of the current practice of TLE. Lead extraction was associated with a higher success rate with lower all cause complication and mortality rates in high volume compared with low volume centres.
  •  
4.
  • Di Cori, Andrea, et al. (författare)
  • Clinical impact of antithrombotic therapy in transvenous lead extraction complications : a sub-analysis from the ESC-EORP EHRA ELECTRa (European Lead Extraction ConTRolled) Registry
  • 2019
  • Ingår i: Europace. - : Oxford University Press. - 1099-5129 .- 1532-2092. ; 21:7, s. 1096-1105
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: A sub-analysis of the ESC-EHRA European Lead Extraction ConTRolled (ELECTRa) Registry to evaluate the clinical impact of antithrombotic (AT) on transvenous lead extraction (TLE) safety and efficacy.METHODS AND RESULTS: ELECTRa outcomes were compared between patients without AT therapy (No AT Group) and with different pre-operative AT regimens, including antiplatelets (AP), anticoagulants (AC), or both (AP + AC). Out of 3510 pts, 2398 (68%) were under AT pre-operatively. AT patients were older with more comorbidities (P < 0.0001). AT subgroups, defined as AP, AC, or AP + AC, were 1096 (31.2%), 985 (28%), and 317 (9%), respectively. Regarding AP patients, 1413 (40%) were under AP, 1292 (91%) with a single AP, interrupted in 26% about 3.8 ± 3.7 days before TLE. In total, 1302 (37%) patients were under AC, 881 vitamin K antagonist (68%), 221 (17%) direct oral anticoagulants, 155 (12%) low weight molecular heparin, and 45 (3.5%) unfractionated heparin. AC was 'interrupted without bridging' in 696 (54%) and 'interrupted with bridging' in 504 (39%) about 3.3 ± 2.3 days before TLE, and 'continued' in 87 (7%). TLE success rate was high in all subgroups. Only overall in-hospital death (1.4%), but not the procedure-related one, was higher in the AT subgroups (P = 0.0500). Age >65 years and New York Heart Association Class III/IV, but not AT regimens, were independent predictors of death for any cause. Haematomas were more frequent in AT subgroups, especially in AC 'continued' (P = 0.025), whereas pulmonary embolism in the No-AT (P < 0.01).CONCLUSIONS: AT minimization is safe in patients undergoing TLE. AT does not seem to predict death but identifies a subset of fragile patients with a worse in-hospital TLE outcome.
  •  
5.
  • Levi, Nir, et al. (författare)
  • Lead fixation mechanism impacts outcome of transvenous lead extraction : Data from the European Lead Extraction ConTRolled Registry
  • 2022
  • Ingår i: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 24:5, s. 817-827
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: The aims of this study is to characterize the transvenous lead extraction (TLE) population with active (A) compared with passive fixation (PFix) leads and to compare the safety, efficacy, and ease of extracting active fixation (AFix) compared with PFix right atrial (RA) and right ventricular (RV) leads.METHODS AND RESULTS: The European Lead Extraction ConTRolled Registry (ELECTRa) was analysed. Patients were divided into three groups; those with only AFix, only PFix, and combined Fix leads. Three outcomes were defined. Difficult extraction, complete radiological, and clinical success. Multivariate model was used to analyse the independent effect of Fix mechanism on these outcomes. The study included 2815 patients, 1456 (51.7%) with only AFix leads, 982 (34.9%) with only PFix leads, and 377 (13.4%) with combined Fix leads. Patients with AFix leads were younger with shorter lead dwelling time. Infection was the leading cause for TLE among the combined Fix group with lowest rates among AFix group. No difference in complications rates was noted between patients with only AFix vs. PFix leads. Overall, there were 1689 RA (1046 AFix and 643 PFix) and 2617 RV leads (1441 AFix and 1176 PFix). Multivariate model demonstrated that PFix is independently associated with more difficult extraction for both RA and RV leads, lower radiological success in the RA but has no effect on clinical success.CONCLUSION: Mechanism of Fix impact the ease of TLE of RA and RV leads and rates of complete radiological success in the RA but not clinical success. These findings should be considered during implantation and TLE procedures.
  •  
6.
  • Mehta, Vishal S., et al. (författare)
  • Machine learning-derived major adverse event prediction of patients undergoing transvenous lead extraction : Using the ESC EHRA EORP European lead extraction ConTRolled ELECTRa registry
  • 2022
  • Ingår i: Heart Rhythm. - : Elsevier. - 1547-5271 .- 1556-3871. ; 19:6, s. 885-893
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND Transvenous lead extraction (TLE) remains a high-risk procedure. OBJECTIVE The purpose of this study was to develop a machine learning (ML)-based risk stratification system to predict the risk of major adverse events (MAEs) after TLE. A MAE was defined as procedure-related major complication and procedure-related death. METHODS We designed and evaluated an ML-based risk stratification system trained using the European Lead Extraction ConTRolled (ELECTRa) registry to predict the risk of MAEs in 3555 patients undergoing TLE and tested this on an independent registry of 1171 patients. ML models were developed, including a self-normalizing neural network (SNN), stepwise logistic regression model ("stepwise model"), support vector machines, and random forest model. These were compared with the ELECTRa Registry Outcome Score (EROS) for MAEs. RESULTS There were 53 MAEs (1.7%) in the training cohort and 24 (2.4%) in the test cohort. Thirty-two clinically important features were used to train the models. ML techniques were similar to EROS by balanced accuracy (stepwise model: 0.74 vs EROS: 0.70) and superior by area under the curve (support vector machines: 0.764 vs EROS: 0.677). The SNN provided a finite risk for MAE and accurately identified MAE in 14 of 169 "high (<80%) risk" patients (8.3%) and no MAEs in all 198 "low (,20%) risk" patients (100%). CONCLUSION ML models incrementally improved risk prediction for identifying those at risk of MAEs. The SNN has the additional advantage of providing a personalized finite risk assessment for patients. This may aid patient decision making and allow better preoperative risk assessment and resource allocation.
  •  
7.
  • Nof, Eyal, et al. (författare)
  • Comparison of outcomes in infected cardiovascular implantable electronic devices between complete, partial, and failed lead removal : an ESC-EHRA-EORP ELECTRa (European Lead Extraction ConTrolled) registry
  • 2019
  • Ingår i: Europace. - : Oxford University Press. - 1099-5129 .- 1532-2092. ; 21:12, s. 1876-1889
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: The present study sought to determine predictors for success and outcomes of patients who underwent cardiac implantable electronic devices (CIED) extraction indicated for systemic or local CIED related infection in particular where complete lead removal could not be achieved.METHODS AND RESULTS: ESC-EORP ELECTRa (European Lead Extraction ConTRolled Registry) is a European prospective lead extraction registry. Out of the total cohort, 1865/3510 (52.5%) patients underwent removal due to CIED related infection. Predictors and outcomes of failure were analysed. Complete removal was achieved in 1743 (93.5%) patients, partial (<4 cm of lead left) in 88 (4.7%), and failed (>4 cm of lead left) in 32 (1.8%) patients. Removal success was unrelated to type of CIED infection (pocket or systemic). Predictors for failure were older leads and older patients [odds ratio (OR) 1.14 (1.08-1.19), P < 0.0001 and OR 2.68 (1.22-5.91), P = 0.0146, respectively]. In analysis by lead, predictors for failure were: pacemaker vs. defibrillator removal and failure to engage the locking stylet all the way to the tip [OR 0.20 (0.04-0.95), P = 0.03 and OR 0.32 (0.13-0.74), P = 0.008, respectively]. Significantly higher complication rates were noted in the failure group (40.6% vs. 15.9 for partial and 8.7% for success groups, P < 0.0001). Failure to remove a lead was a strong predictor for in hospital mortality [hazard ratio of 2.05 (1.01-4.16), P = 0.046].CONCLUSION: A total of 6.5% of infected CIED patients failed attempted extraction. Only were >4 cm of lead remained resulted in higher procedural complications and mortality rates.
  •  
8.
  • Polewczyk, Anna, et al. (författare)
  • Transvenous lead extraction procedures in women based on ESC-EHRA EORP European Lead Extraction ConTRolled ELECTRa registry : is female sex a predictor of complications?
  • 2019
  • Ingår i: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 21:12
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: Female sex is considered an independent risk factor of transvenous leads extraction (TLE) procedure. The aim of the study was to evaluate the effectiveness of TLE in women compared with men.METHODS AND RESULTS: A post hoc analysis of risk factors and effectiveness of TLE in women and men included in the ESC-EHRA EORP ELECTRa registry was conducted. The rate of major complications was 1.96% in women vs. 0.71% in men; P = 0.0025. The number of leads was higher in men (mean 1.89 vs. 1.71; P < 0.0001) with higher number of abandoned leads in women (46.04% vs. 34.82%; P < 0.0001). Risk factors of TLE differed between the sexes, of which the major were: signs and symptoms of venous occlusion [odds ratio (OR) 3.730, confidence interval (CI) 1.401-9.934; P = 0.0084], cumulative leads dwell time (OR 1.044, CI 1.024-1.065; P < 0.001), number of generator replacements (OR 1.029, CI 1.005-1.054; P = 0.0184) in females and the number of leads (OR 6.053, CI 2.422-15.129; P = 0.0001), use of powered sheaths (OR 2.742, CI 1.404-5.355; P = 0.0031), and white blood cell count (OR 1.138, CI 1.069-1.212; P < 0.001) in males. Individual radiological and clinical success of TLE was 96.29% and 98.14% in women compared with 98.03% and 99.21% in men (P = 0.0046 and 0.0098).CONCLUSION: The efficacy of TLE was lower in females than males, with a higher rate of periprocedural major complications. The reasons for this difference are probably related to disparities in risk factors in women, including more pronounced leads adherence to the walls of the veins and myocardium. Lead management may be key to the effectiveness of TLE in females.
  •  
9.
  • Regoli, François, et al. (författare)
  • Impact of anticoagulation therapy on outcomes in patients with cardiac implantable resynchronization devices undergoing transvenous lead extraction : A substudy of the ESC-EHRA EORP ELECTRa (European Lead Extraction ConTRolled) Registry
  • 2019
  • Ingår i: Cardiovascular Electrophysiology. - : Wiley. - 1045-3873 .- 1540-8167. ; 30:7, s. 1086-1095
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION: Little data are available on anticoagulation (AC) management in patients with cardiac resynchronization (CRT) devices who undergo transvenous lead extraction (TLE) procedure. We investigated the impact of AC on periprocedural complications in CRT patients undergoing TLE, enrolled in the ESC-EHRA European Lead Extraction ConTrolled (ELECTRa) registry.METHODS AND RESULTS: All CRT patients treated with TLE enrolled in the registry were considered. Perioperative AC management was left to the discretion of the Center. Major and minor intraprocedural and postprocedural complications were compared between patients without AC (Gp1) and patients with AC (Gp2). Regression analyses were performed to identify predictors of complications for Gp2. Out of 734 CRT pts, 328 (44.7%) were under AC (Gp2). Patients from Gp2 presented lower LVEF (Gp2 32.5 ± 10.9 vs Gp1 34.5 ± 11.9%; P = 0.03), more advanced heart failure disease (NYHA III/IV: Gp2 42.0 vs Gp1 31.5%; P = 0.02), and renal impairment (Gp2 39.0 vs Gp1 24.3%; P < 0.001). Perioperative regimens included AC interruption (Gp2A: n = 169, 51.5%), "bridging" (Gp2B: n = 135, 41.2%), or continued AC (Gp2C: n = 24, 7.3%). TLE complete success rates (98% in both groups) and major complication rates were comparable for both groups; minor bleeding events were more frequent in Gp2 (5.5%) compared to Gp1 (2.5%; P = 0.051). No independent predictors were identified for Gp2, but minor complications were associated with "bridging" approach (Gp2B: 16 events vs Gp2A/C: 9 events; P = 0.020).CONCLUSION: CRT patients treated with TLE under AC were more compromised but did not present more major complications compared to patients without AC. More minor complications were associated with "bridging" AC regimen.
  •  
10.
  • Segreti, Luca, et al. (författare)
  • Procedural outcomes associated with transvenous lead extraction in patients with abandoned leads : an ESC-EHRA ELECTRa (European Lead Extraction ConTRolled) Registry Sub-Analysis.
  • 2019
  • Ingår i: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 21:4, s. 645-654
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: The decision to abandon or extract superfluous leads remains controversial. We sought to compare procedural outcome of patients with and without abandoned leads undergoing transvenous lead extraction (TLE).Methods and results: An analysis of the ESC-EHRA European Lead Extraction ConTRolled ELECTRa registry was conducted. Patients were stratified into two groups based on the presence (Group 1) or absence (Group 2) of abandoned leads at the time for extraction. Out of 3508 TLE procedures, 422 patients (12.0%) had abandoned leads (Group 1). Group 1 patients were older and more likely to have implantable cardioverter-defibrillator devices, infection indication (78.8% vs. 49.8%), and vegetations (24.6% vs. 15.3%). Oldest lead dwelling time was longer in Group 1 (10.9 vs. 6.3 years) as was the number of extracted leads per patient (3.2 vs. 1.7). Manual traction failure (94.5% vs. 78.8%), powered sheath use (50.7% vs. 28.4%), and femoral approach were higher in Group 1 (P < 0.0001). Procedural success rate and clinical success (89.8% vs. 96.6%, P < 0.0001) were lower in Group 1. Major complication including deaths (5.5% vs. 2.3%, P = 0.0007) and procedure related major complications (3.3% vs. 1.4%, P = 0.0123) were higher in Group 1. The presence of abandoned leads at the time of TLE was an independent predictor of clinical failure [odds ratio (OR) 2.31, confidence interval (CI) 1.57-3.40] and complications [OR 1.69, CI 1.22-2.35]. receiver-operating characteristic curve analysis showed a dwell time threshold of 9 years for radiological failure and major complications.Conclusions: Previously abandoned leads at the time of TLE were associated with increased procedural complexity, clinical failure, and major complication, which may have important implications for future studies regarding managing of lead failures.
  •  