SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Becker Richard C.) srt2:(2006-2009);lar1:(uu)"

Sökning: WFRF:(Becker Richard C.) > (2006-2009) > Uppsala universitet

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abdesselam, A., et al. (författare)
  • Engineering for the ATLAS SemiConductor Tracker (SCT) end-cap
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3
  • Tidskriftsartikel (refereegranskat)abstract
    • The ATLAS SemiConductor Tracker (SCT) is a silicon-strip tracking detector which forms part of the ATLAS inner detector. The SCT is designed to track charged particles produced in proton-proton collisions at the Large Hadron Collider (LHC) at CERN at an energy of 14 TeV. The tracker is made up of a central barrel and two identical end-caps. The barrel contains 2112 silicon modules, while each end-cap contains 988 modules. The overall tracking performance depends not only on the intrinsic measurement precision of the modules but also on the characteristics of the whole assembly, in particular, the stability and the total material budget. This paper describes the engineering design and construction of the SCT end-caps, which are required to support mechanically the silicon modules, supply services to them and provide a suitable environment within the inner detector. Critical engineering choices are highlighted and innovative solutions are presented - these will be of interest to other builders of large-scale tracking detectors. The SCT end-caps will be fully connected at the start of 2008. Further commissioning will continue, to be ready for proton-proton collision data in 2008.
  •  
2.
  • Abdesselam, A., et al. (författare)
  • The ATLAS semiconductor tracker end-cap module
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 575:3, s. 353-389
  • Tidskriftsartikel (refereegranskat)abstract
    • The challenges for the tracking detector systems at the LHC are unprecedented in terms of the number of channels, the required read-out speed and the expected radiation levels. The ATLAS Semiconductor Tracker. (SCT) end-caps have a total of about 3 million electronics channels each reading out every 25 ns into its own on-chip 3.3 mu s buffer. The highest anticipated dose after 10 years operation is 1.4x10(14) cm(-2) in units of 1 MeV neutron equivalent (assuming the damage factors scale with the non-ionising energy loss). The forward tracker has 1976 double-sided modules, mostly of area similar to 70 cm(2), each having 2 x 768 strips read out by six ASICs per side. The requirement to achieve an average perpendicular radiation length of 1.5% X-0, while coping with up to 7 W dissipation per module (after irradiation), leads to stringent constraints on the thermal design. The additional requirement of 1500e(-) equivalent noise charge (ENC) rising to only 1800e(-) ENC after irradiation, provides stringent design constraints on both the high-density Cu/Polyimide flex read-out circuit and the ABCD3TA read-out ASICs. Finally, the accuracy of module assembly must not compromise the 16 mu m (r phi) resolution perpendicular to the strip directions or 580 mu m radial resolution coming from the 40 mrad front-back stereo angle. A total of 2210 modules were built to the tight tolerances and specifications required for the SCT. This was 234 more than the 1976 required and represents a yield of 93%. The component flow was at times tight, but the module production rate of 40-50 per week was maintained despite this. The distributed production was not found to be a major logistical problem and it allowed additional flexibility to take advantage of where the effort was available, including any spare capacity, for building the end-cap modules. The collaboration that produced the ATLAS SCT end-cap modules kept in close contact at all times so that the effects of shortages or stoppages at different sites could be rapidly resolved.
  •  
3.
  • Alexander, John H., et al. (författare)
  • Apixaban, an oral, direct, selective factor Xa inhibitor, in combination with antiplatelet therapy after acute coronary syndrome : results of the Apixaban for Prevention of Acute Ischemic and Safety Events (APPRAISE) trial
  • 2009
  • Ingår i: Circulation. - 0009-7322 .- 1524-4539. ; 119:22, s. 2877-2885
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: After an acute coronary syndrome, patients remain at risk of recurrent events. Apixaban, an oral direct factor Xa inhibitor, is a novel anticoagulant that may reduce these events but also poses a risk of bleeding. METHODS AND RESULTS: Apixaban for Prevention of Acute Ischemic and Safety Events (APPRAISE) was a phase 2, double-blind, placebo-controlled, dose-ranging study. Patients (n=1715) with recent ST-elevation or non-ST-elevation acute coronary syndrome were randomized to 6 months of placebo (n=611) or 1 of 4 doses of apixaban: 2.5 mg twice daily (n=317), 10 mg once daily (n=318), 10 mg twice daily (n=248), or 20 mg once daily (n=221). Nearly all patients received aspirin; 76% received clopidogrel. The primary outcome was International Society of Thrombosis and Hemostasis major or clinically relevant nonmajor bleeding. A secondary outcome was cardiovascular death, myocardial infarction, severe recurrent ischemia, or ischemic stroke. At the recommendation of the Data Monitoring Committee, the 2 higher-dose apixaban arms were discontinued because of excess total bleeding. Compared with placebo, apixaban 2.5 mg twice daily (hazard ratio, 1.78; 95% confidence interval, 0.91 to 3.48; P=0.09) and 10 mg once daily (hazard ratio, 2.45; 95% confidence interval, 1.31 to 4.61; P=0.005) resulted in a dose-dependent increase in major or clinically relevant nonmajor bleeding. Apixaban 2.5 mg twice daily (hazard ratio, 0.73; 95% confidence interval, 0.44 to 1.19; P=0.21) and 10 mg once daily (hazard ratio, 0.61; 95% confidence interval, 0.35 to 1.04; P=0.07) resulted in lower rates of ischemic events compared with placebo. The increase in bleeding was more pronounced and the reduction in ischemic events was less evident in patients taking aspirin plus clopidogrel than in those taking aspirin alone. CONCLUSIONS: We observed a dose-related increase in bleeding and a trend toward a reduction in ischemic events with the addition of apixaban to antiplatelet therapy in patients with recent acute coronary syndrome. The safety and efficacy of apixaban may vary depending on background antiplatelet therapy. Further testing of apixaban in patients at risk of recurrent ischemic events is warranted.
  •  
4.
  • Wallentin, Lars, 1943-, et al. (författare)
  • Ticagrelor versus clopidogrel in patients with acute coronary syndromes
  • 2009
  • Ingår i: New England Journal of Medicine. - 0028-4793 .- 1533-4406. ; 361:11, s. 1045-1057
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Ticagrelor is an oral, reversible, direct-acting inhibitor of the adenosine diphosphate receptor P2Y12 that has a more rapid onset and more pronounced platelet inhibition than clopidogrel. METHODS: In this multicenter, double-blind, randomized trial, we compared ticagrelor (180-mg loading dose, 90 mg twice daily thereafter) and clopidogrel (300-to-600-mg loading dose, 75 mg daily thereafter) for the prevention of cardiovascular events in 18,624 patients admitted to the hospital with an acute coronary syndrome, with or without ST-segment elevation. RESULTS: At 12 months, the primary end point--a composite of death from vascular causes, myocardial infarction, or stroke--had occurred in 9.8% of patients receiving ticagrelor as compared with 11.7% of those receiving clopidogrel (hazard ratio, 0.84; 95% confidence interval [CI], 0.77 to 0.92; P<0.001). Predefined hierarchical testing of secondary end points showed significant differences in the rates of other composite end points, as well as myocardial infarction alone (5.8% in the ticagrelor group vs. 6.9% in the clopidogrel group, P=0.005) and death from vascular causes (4.0% vs. 5.1%, P=0.001) but not stroke alone (1.5% vs. 1.3%, P=0.22). The rate of death from any cause was also reduced with ticagrelor (4.5%, vs. 5.9% with clopidogrel; P<0.001). No significant difference in the rates of major bleeding was found between the ticagrelor and clopidogrel groups (11.6% and 11.2%, respectively; P=0.43), but ticagrelor was associated with a higher rate of major bleeding not related to coronary-artery bypass grafting (4.5% vs. 3.8%, P=0.03), including more instances of fatal intracranial bleeding and fewer of fatal bleeding of other types. CONCLUSIONS: In patients who have an acute coronary syndrome with or without ST-segment elevation, treatment with ticagrelor as compared with clopidogrel significantly reduced the rate of death from vascular causes, myocardial infarction, or stroke without an increase in the rate of overall major bleeding but with an increase in the rate of non-procedure-related bleeding.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy