SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Blankenberg Stefan) ;mspu:(researchreview)"

Sökning: WFRF:(Blankenberg Stefan) > Forskningsöversikt

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Chiang, Cho-Han, et al. (författare)
  • Performance of the European Society of Cardiology 0/1-Hour, 0/2-Hour, and 0/3-Hour Algorithms for Rapid Triage of Acute Myocardial Infarction : An International Collaborative Meta-analysis
  • 2022
  • Ingår i: Annals of Internal Medicine. - 0003-4819. ; 175:1, s. 101-113
  • Forskningsöversikt (refereegranskat)abstract
    • BACKGROUND: The 2020 European Society of Cardiology (ESC) guidelines recommend using the 0/1-hour and 0/2-hour algorithms over the 0/3-hour algorithm as the first and second choices of high-sensitivity cardiac troponin (hs-cTn)-based strategies for triage of patients with suspected acute myocardial infarction (AMI).PURPOSE: To evaluate the diagnostic accuracies of the ESC 0/1-hour, 0/2-hour, and 0/3-hour algorithms.DATA SOURCES: PubMed, Embase, Cochrane Central Register of Controlled Trials, Web of Science, and Scopus from 1 January 2011 to 31 December 2020. (PROSPERO: CRD42020216479).STUDY SELECTION: Prospective studies that evaluated the ESC 0/1-hour, 0/2-hour, or 0/3-hour algorithms in adult patients presenting with suspected AMI.DATA EXTRACTION: The primary outcome was index AMI. Twenty unique cohorts were identified. Primary data were obtained from investigators of 16 cohorts and aggregate data were extracted from 4 cohorts. Two independent authors assessed each study for methodological quality.DATA SYNTHESIS: A total of 32 studies (20 cohorts) with 30 066 patients were analyzed. The 0/1-hour algorithm had a pooled sensitivity of 99.1% (95% CI, 98.5% to 99.5%) and negative predictive value (NPV) of 99.8% (CI, 99.6% to 99.9%) for ruling out AMI. The 0/2-hour algorithm had a pooled sensitivity of 98.6% (CI, 97.2% to 99.3%) and NPV of 99.6% (CI, 99.4% to 99.8%). The 0/3-hour algorithm had a pooled sensitivity of 93.7% (CI, 87.4% to 97.0%) and NPV of 98.7% (CI, 97.7% to 99.3%). Sensitivity of the 0/3-hour algorithm was attenuated in studies that did not use clinical criteria (GRACE score <140 and pain-free) compared with studies that used clinical criteria (90.2% [CI, 82.9 to 94.6] vs. 98.4% [CI, 88.6 to 99.8]). All 3 algorithms had similar specificities and positive predictive values for ruling in AMI, but heterogeneity across studies was substantial. Diagnostic performance was similar across the hs-cTnT (Elecsys; Roche), hs-cTnI (Architect; Abbott), and hs-cTnI (Centaur/Atellica; Siemens) assays.LIMITATION: Diagnostic accuracy, inclusion and exclusion criteria, and cardiac troponin sampling time varied among studies.CONCLUSION: The ESC 0/1-hour and 0/2-hour algorithms have higher sensitivities and NPVs than the 0/3-hour algorithm for index AMI.PRIMARY FUNDING SOURCE: National Taiwan University Hospital.
  •  
2.
  • Katus, Hugo, et al. (författare)
  • Early diagnosis of acute coronary syndrome
  • 2017
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 38:41, s. 3049-3055
  • Forskningsöversikt (refereegranskat)abstract
    • The diagnostic evaluation of acute chest pain has been augmented in recent years by advances in the sensitivity and precision of cardiac troponin assays, new biomarkers, improvements in imaging modalities, and release of new clinical decision algorithms. This progress has enabled physicians to diagnose or rule-out acute myocardial infarction earlier after the initial patient presentation, usually in emergency department settings, which may facilitate prompt initiation of evidence-based treatments, investigation of alternative diagnoses for chest pain, or discharge, and permit better utilization of healthcare resources. A non-trivial proportion of patients fall in an indeterminate category according to rule-out algorithms, and minimal evidence-based guidance exists for the optimal evaluation, monitoring, and treatment of these patients. The Cardiovascular Round Table of the ESC proposes approaches for the optimal application of early strategies in clinical practice to improve patient care following the review of recent advances in the early diagnosis of acute coronary syndrome. The following specific 'indeterminate' patient categories were considered: (i) patients with symptoms and high-sensitivity cardiac troponin <99th percentile; (ii) patients with symptoms and high-sensitivity troponin <99th percentile but above the limit of detection; (iii) patients with symptoms and high-sensitivity troponin >99th percentile but without dynamic change; and (iv) patients with symptoms and high-sensitivity troponin >99th percentile and dynamic change but without coronary plaque rupture/erosion/dissection. Definitive evidence is currently lacking to manage these patients whose early diagnosis is 'indeterminate' and these areas of uncertainty should be assigned a high priority for research.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy