SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bruze Magnus) ;pers:(Björk Jonas)"

Sökning: WFRF:(Bruze Magnus) > Björk Jonas

  • Resultat 1-10 av 17
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Sterner, Therese, et al. (författare)
  • IgE sensitization in a cohort of adolescents in southern Sweden and its relation to allergic symptoms
  • 2019
  • Ingår i: Clinical and Molecular Allergy. - : Springer Science and Business Media LLC. - 1476-7961. ; 17
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: There is a strong and consistent association between IgE sensitization and allergy, wheeze, eczema and food hypersensitivity. These conditions are also found in non-sensitized humans, and sensitization is found among individuals without allergy-related diseases. The aim of this study was to analyse the sensitization profile in a representative sample of the population, and to relate patterns of allergens and allergen components to allergic symptoms. Methods: A population of 195 adolescents took part in this clinical study, which included a self-reported questionnaire and in vitro IgE testing. Results: Sensitization to airborne allergens was significantly more common than sensitization to food allergens, 43% vs. 14%, respectively. IgE response was significantly higher in airborne allergens among adolescents with rhinitis (p < 0.001) and eczema (p < 0.01). Among 53 children with allergic symptoms according to the questionnaire, 60% were sensitized. Sensitization to food allergens was found among those with rhinitis, but only to PR-10 proteins. None of the participants had IgE to seed storage proteins. Conclusion: The adolescents in this study, taken from a normal Swedish population, were mainly sensitized to grass pollen and rarely to specific food allergens. The major grass pollen allergen Phl p 1 was the main sensitizer, followed by Cyn d 1 and Phl p 2. Sixty-one percent reporting any allergic symptom were sensitized, and the allergen components associated with wheeze and rhinoconjunctivitis were Fel d 4, Der f 2 and Can f 5.
  •  
2.
  • Svedman, Cecilia, et al. (författare)
  • A correlation found between contact allergy to stent material and restenosis of the coronary arteries.
  • 2009
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 60:3, s. 158-164
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Metallic implants, stents, are increasingly being used especially in patients with stenosis of the cardiac vessels. Ten to thirty per cent of the patients suffer from restenosis regardless of aetiology. We have shown increased frequency of contact allergy to stent metals in stented patients. OBJECTIVES: To we evaluate whether contact allergy to stent material is a risk factor for restenosis. METHODS: Patients with stainless steel stents, with or without gold plating, were epicutaneously tested and answered a questionnaire. The restenosis rate was evaluated. RESULTS: We found a correlation between contact allergy to gold, gold stent, and restenosis (OR 2.3, CI 1.0-5.1, P = 0.04). The risk for restenosis was threefold increased when the patient was gold allergic and stented with a gold-plated stent. An increased degree of chest pain in gold-allergic patients stented with gold-plated stent was found. CONCLUSIONS: We found a correlation between contact allergy to gold, gold-stent, and restenosis. It may be of importance to consider contact allergy when developing new materials for stenting.
  •  
3.
  • Ekqvist, Susanne, et al. (författare)
  • A correlation found between gold concentration in blood and patch test reactions in patients with coronary stents.
  • 2008
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 59:3, s. 137-142
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Patients with dental gold restorations are known to have a higher level of gold concentration in blood (B-Au). OBJECTIVES: To further investigate, in a study on patients with intracoronary stents and contact allergy to metals, the gold and nickel release from stainless steel stent with (Au stent) and without (Ni stent) gold plating. METHOD: A total of 460 patients treated with stenting underwent patch testing with metals, and information on gold and nickel exposure and blood samples were collected. About 200 blood samples were randomly selected and the analysis of B-Au and nickel concentration in blood (B-Ni) was made using inductively coupled plasma mass spectrometry. RESULTS: There was a correlation between the intensity of Au patch test reaction and B-Au (P < 0.001). This correlation could not be seen between Ni patch test reaction and B-Ni. A Au stent gave a fivefold higher B-Au than a Ni stent. CONCLUSIONS: Gold is released from the Au stent and patients with a Au stent have a fivefold higher B-Au than patients with an Ni stent. The patch test reactions for gold were correlated with B-Au.
  •  
4.
  • Ekqvist, Susanne, et al. (författare)
  • Does gold concentration in the blood influence the result of patch testing to gold?
  • 2009
  • Ingår i: British Journal of Dermatology. - : Oxford University Press (OUP). - 1365-2133 .- 0007-0963. ; 160:5, s. 1016-1021
  • Tidskriftsartikel (refereegranskat)abstract
    • We have recently found a correlation between contact allergy to gold sodium thiosulphate (GSTS) and gold concentration in the blood (B-Au) in a stented population: the higher the B-Au, the stronger the patch-test reaction. To further investigate the correlation between B-Au and patch-test reactivity to gold. In this provocation control cross-over trial of 24 patients with dermatitis with a known contact allergy to gold, the patients were randomized into two groups where one was topically provoked to gold (15 mg GSTS) and one to the control. All patients were simultaneously patch tested with GSTS in 10 aqueous dilutions (1.1 mg GSTS). Patch-test readings were performed and blood was drawn. After 6 weeks, the experiment was repeated and the group that had previously been provoked with gold was now provoked with the control and vice versa. B-Au was higher after gold provocation whereas no treatment effect was discerned for minimal eliciting concentration (MEC) or summarized test score (STS). Instead, significant differences in period effect were observed implying higher B-Au and STS and lower MEC on test occasion II. The most likely explanation is the increased B-Au and/or booster effect from test occasion I. There was a correlation between B-Au and MEC: the higher the B-Au, the lower the MEC. The correlation between B-Au and MEC indicates that the B-Au is of importance for the skin reactivity to gold.
  •  
5.
  • Ekqvist, Susanne, et al. (författare)
  • High frequency of contact allergy to gold in patients with endovascular coronary stents
  • 2007
  • Ingår i: British Journal of Dermatology. - : Oxford University Press (OUP). - 1365-2133 .- 0007-0963. ; 157:4, s. 730-738
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Stent implantation is an effective method for treatment of atherosclerotic disease. Factors predisposing to in-stent restenosis are still largely unknown. Contact allergy to metal ions eluted from the stent has been suggested to be a risk factor. Objectives To explore whether there is a possible induction of contact allergy to metals used in stents among patients with a stainless steel stent containing nickel (Ni stent) and patients with a gold-plated stent (Au stent). Methods Adults (n = 484) treated with coronary stent implantation participated in the study with patch testing. The study design was retrospective and cross-sectional with no assessment of contact allergy before stenting. Age- and sex-matched patch-tested patients with dermatitis (n = 447) served as controls. Results Of Au-stented patients, 54 of 146 (37%) were allergic to gold compared with 85 of 447 (19%) controls (P < 0.001). Within the stented population there were no statistically significant differences in contact allergy to gold or nickel between Ni-stented and Au-stented patients. In multivariate models where other risk factors for contact allergy to gold were considered, the Au stent showed a trend towards statistical significance (odds ratio 1.43, 95% confidence interval 0.95-2.16; P = 0.09). Conclusions As the frequency of contact allergy to gold is higher in stented patients independent of stent type it suggests a previous sensitization. However, several pieces of circumstantial evidence as well as statistical analysis indicate the possibility of sensitization in the coronary vessel by the Au stent. Ni stents and Au stents should not be ruled out as risk factors for induction of contact allergy to these metals.
  •  
6.
  • Hamnerius, Nils, et al. (författare)
  • Hand eczema and occupational contact allergies in healthcare workers with a focus on rubber additives
  • 2018
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873. ; 79:3, s. 149-156
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Hand eczema (HE) in healthcare workers (HCWs) is common. Besides wet work, healthcare work also implies exposure to contact allergens. Objectives: To assess HE and contact allergy related to occupational exposures in HCWs. Methods: In a cross-sectional study, 311 HCWs with HE within the preceding 12 months and a control group of 114 HCWs without HE were investigated with the baseline series and a special patch test series based on substances found in the gloves, soaps, alcoholic hand disinfectants and hand creams provided at the hospitals. Results: Contact allergy to rubber additives was significantly more common in HCWs with HE (6%) than in HCWs without HE (1%, P =.02). The corresponding percentages for fragrances were 11% and 3%, respectively (P =.004). Occupational HE was found in 193 of 311 (62%) HCWs. Of these, 22 of 193 (11%) had occupational allergic contact dermatitis, including 17 with glove-related rubber contact allergy. Contact allergy to diphenylguanidine was as common as contact allergy to thiurams. Occupational contact allergy to rubber additives was significantly associated with sick-leave related to HE. Conclusion: Contact allergy to rubber additives in medical gloves is the most common cause of occupational allergic contact dermatitis in HCWs. Aimed patch testing with relevant rubber additives is mandatory when HE in HCWs is investigated.
  •  
7.
  • Hamnerius, Nils, et al. (författare)
  • Skin Exposures, Hand Eczema and Facial Skin Disease in Healthcare Workers During the COVID-19 Pandemic: A Cross-sectional Study
  • 2021
  • Ingår i: Acta Dermato-Venereologica. - : Medical Journals Sweden AB. - 0001-5555 .- 1651-2057. ; 101:9
  • Tidskriftsartikel (refereegranskat)abstract
    • The COVID-19 pandemic has led to enhanced hygiene procedures and use of personal protective equipment, but also to increased attention to occupational skin disease in healthcare workers. The occurrence of hand and facial skin disease in > 5,000 Swedish healthcare workers was investigated in a questionnaire survey. Levels of skin exposure related to hygiene procedures and personal protective equipment were recorded. Caring for patients with COVID-19 entailed higher levels of wet work and face mask exposures, and was associated with higher 1-year prevalence of both hand eczema (36%) and facial skin disease (32%) compared with not being directly engaged in COVID-19 care (28% and 22%, respectively). Acne and eczema were the most common facial skin diseases; for both, a dose-dependent association with face mask use was found. Dose-dependent associations could be shown between hand eczema and exposure to soap and gloves, but not to alcohol-based hand disinfectants.
  •  
8.
  • Morgardt-Ryberg, Kristina, et al. (författare)
  • Is contact allergy to disperse dyes and related substances associated with textile dermatitis?
  • 2009
  • Ingår i: British Journal of Dermatology. - : Oxford University Press (OUP). - 1365-2133 .- 0007-0963. ; 160, s. 107-115
  • Tidskriftsartikel (refereegranskat)abstract
    • Summary Background Disperse dyes (DDs) are the most common sensitizers among textile dyes, but there is little knowledge of the clinical relevance of positive patch test reactions. Objective To investigate if patient-reported textile-related skin problems can be explained by contact allergy to eight different DDs and/or to chemically related substances, by occupation or by atopic constitution, and if the skin problems are influenced by age or sex. Methods A questionnaire on textile-related skin problems was answered by 858 of 982 consecutively patch tested patients in Malmö, Sweden and in Leuven, Belgium. The baseline series used for patch testing was supplemented with a textile dye mix (TDM) consisting of the eight DDs and with the separate dyes. The association between textile-related skin problems and contact allergy to the DDs and other risk factors was investigated using multiple logistic regression analysis. Results Eighteen per cent of the patients suspected textiles as a cause of their skin problems. Atopic constitution and female sex were risk factors for skin reactions. Synthetic materials were the most common textiles to give skin problems. A significant association was found between self-reported textile-related skin problems and contact allergy to para-phenylenediamine (PPD) [adjusted odds ratio (OR) 2.1; 95% confidence interval (CI) 1.0-4.3]. A similar, but more imprecise, adjusted OR was found for TDM (OR 1.9; 95% CI 0.57-5.6). Contact allergy to black rubber mix was too rare to be evaluated. Conclusions Contact allergy to PPD was a more prevalent indicator for skin reactions to textiles than the TDM used in this study.
  •  
9.
  • Netterlid, Eva, et al. (författare)
  • Does Allergen-specific Immunotherapy Induce Contact Allergy to Aluminium?
  • 2013
  • Ingår i: Acta Dermato-Venereologica. - : Medical Journals Sweden AB. - 1651-2057 .- 0001-5555. ; 93, s. 50-56
  • Tidskriftsartikel (refereegranskat)abstract
    • Persistent, itching nodules have been reported to appear at the injection site after allergen-specific immuno-therapy with aluminium-precipitated antigen extract, occasionally in conjunction with contact allergy to aluminium. This study aimed to quantify the development of contact allergy to aluminium during allergen-specific immunotherapy. A randomized, controlled, single-blind multicentre study of children and adults entering allergen-specific immunotherapy was performed using questionnaires and patch-testing. A total of 205 individuals completed the study. In the 3 study groups all subjects tested negative to aluminium before allergen-specific immunotherapy and 4 tested positive after therapy. In the control group 4 participants tested positive to aluminium. Six out of 8 who tested positive also had atopic dermatitis. Positive test results were found in 5/78 children and 3/127 adults. Allergen-specific immunotherapy was not shown to be a risk factor for contact allergy to aluminium. Among those who did develop aluminium allergy, children and those with atopic dermatitis were more highly represented.
  •  
10.
  • Netterlid, Eva, et al. (författare)
  • There is an association between contact allergy to aluminium and persistent subcutaneous nodules in children undergoing hyposensitization therapy.
  • 2009
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 60:1, s. 41-49
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The development of persistent itchy nodules at the injection site following hyposensitization therapy with aluminium-precipitated antigen extract has been described in several reports. Occasionally, contact allergy to aluminium has been reported in individuals with such nodules. OBJECTIVES: To investigate if hyposensitization therapy can induce contact allergy to aluminium and examine if there is any association between persistent subcutaneous nodules and aluminium allergy. PATIENTS/METHODS: Sixty-one children with allergic asthma and/or allergic rhinitis participated in the study of whom 37 had had hyposensitization therapy. The study consisted of a non-clinical part based on a questionnaire and a clinical part with a physical examination, self-assessment of itching, and patch testing. To secure an unbiased evaluation of possible reactions, the investigators were blinded. RESULTS: Contact allergy to aluminium was found in eight participants, all in the exposed group (8/37 versus 0/24, P = 0.02). Examination showed nodules on the upper arms in 13 participants, all in the group exposed to hyposensitization therapy. Nodules were over-represented in patients with contact allergy to aluminium. CONCLUSIONS: There was a statistically significant association between contact allergy to aluminium and persistent subcutaneous nodules in children who had had hyposensitization therapy.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 17

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy