SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bruze Magnus) ;pers:(Möller Halvor)"

Sökning: WFRF:(Bruze Magnus) > Möller Halvor

  • Resultat 1-10 av 30
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Isaksson, Marléne, et al. (författare)
  • Patch Testing with Formaldehyde 2.0% in Parallel with 1.0% by the Swedish Contact Dermatitis Research Group
  • 2014
  • Ingår i: Acta Dermato-Venereologica. - : Taylor & Francis. - 0001-5555 .- 1651-2057. ; 94:4, s. 408-410
  • Tidskriftsartikel (refereegranskat)abstract
    • In a multicentre study consecutively patch-tested dermatitis patients were tested simultaneously with 1.0% and 2.0% (w/v) formaldehyde in aqua applied with a micro-pipette (15 mu l) to the filter paper disc in Finn Chambers (0.30 mg/cm(2) and 0.60 mg/cm(2), respectively). A total of 2,122 dermatitis patients were patch-tested. In all, 77 (3.6%) patients reacted positively to formaldehyde; 37 reacted only to 2.0%, 35 reacted to both concentrations and 5 patients reacted only to 1.0%. Significantly more patients were thus diagnosed with contact allergy to formaldehyde with 2.0% compared to 1.0% (p<0.001) without causing more irritant reactions. The detected number of isolated allergic reactions to the 2 formaldehyde-releasers in the Swedish baseline series and not to formaldehyde itself raises the question whether quaternium-15 1.0% and diazolidinyl urea 2.0% should be present in the Swedish baseline series.
  •  
3.
  •  
4.
  • Svedman, Cecilia, et al. (författare)
  • A correlation found between contact allergy to stent material and restenosis of the coronary arteries.
  • 2009
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 60:3, s. 158-164
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Metallic implants, stents, are increasingly being used especially in patients with stenosis of the cardiac vessels. Ten to thirty per cent of the patients suffer from restenosis regardless of aetiology. We have shown increased frequency of contact allergy to stent metals in stented patients. OBJECTIVES: To we evaluate whether contact allergy to stent material is a risk factor for restenosis. METHODS: Patients with stainless steel stents, with or without gold plating, were epicutaneously tested and answered a questionnaire. The restenosis rate was evaluated. RESULTS: We found a correlation between contact allergy to gold, gold stent, and restenosis (OR 2.3, CI 1.0-5.1, P = 0.04). The risk for restenosis was threefold increased when the patient was gold allergic and stented with a gold-plated stent. An increased degree of chest pain in gold-allergic patients stented with gold-plated stent was found. CONCLUSIONS: We found a correlation between contact allergy to gold, gold-stent, and restenosis. It may be of importance to consider contact allergy when developing new materials for stenting.
  •  
5.
  •  
6.
  • Ahlgren, Camilla, et al. (författare)
  • Contact allergies to potential allergens in patients with oral lichen lesions
  • 2014
  • Ingår i: Clinical Oral Investigations. - : Springer. - 1432-6981 .- 1436-3771. ; 18:1, s. 227-237
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the present controlled study was to investigate a possible relationship between contact allergies to potential allergens and oral lichen lesions. Eighty-three patients with oral lichen lesions (OLL) and control groups of age- and gender-matched dermatitis patients (DP, n = 83) and patch-tested dermatitis patients randomly selected from files (PSFF, n = 319) were included in the study. OLL and DP groups were patch-tested epicutaneously and examined intraorally. The frequencies of contact allergy to mercury and carvone were statistically higher in the OLL group than in the DP group. Surfaces of amalgam and composite restorations were statistically more frequent in the OLL group compared to the DP group. Contact allergy to nickel and colophony, the latter with a statistically significant difference, was more common in the DP group. The numerical difference found for nickel allergy was, however, not significant comparing the OLL and PSFF groups. Contact allergy to mercury was overrepresented in patients with OLL and has been reported in previous studies, but the present finding of an overrepresentation of contact allergy to carvone in patients with oral lichen lesions has not been reported previously. Carvone, in addition to mercury and gold, as previously suggested, can be one of the causative or maintenant factors for oral lichen lesions. Carvone-hypersensitive patients with oral lichen lesions should therefore avoid carvone-containing products for oral use.
  •  
7.
  • Ahlgren, Camilla, et al. (författare)
  • Contact Allergy to Gold in Patients with Oral Lichen Lesions.
  • 2012
  • Ingår i: Acta Dermato-Venereologica. - : Medical Journals Sweden AB. - 1651-2057 .- 0001-5555. ; 92:2, s. 138-143
  • Tidskriftsartikel (refereegranskat)abstract
    • The aetiology of oral lichen lesions is obscure. In this study the frequency of contact allergy to gold in 83 patients with oral lichen lesions was compared with that in two control groups, comprising 319 age- and gender-matched patients with dermatitis selected from files and 83 clinically examined dermatitis patients. All patients were tested epicutaneously with gold sodium thiosulphate. The two control groups tested were under examination for a tentative diagnosis of allergic dermatitis not related to oral problems. The frequency of contact allergy to gold was 28.9% in the patients with oral lichen lesions, 18.2% in patients selected from files, and 22.9% in the clinically examined control patients. The difference in frequency between patients with oral lichen lesions and those taken from files was statistically significant.
  •  
8.
  • Ahlgren, Camilla, et al. (författare)
  • Contact allergy to gold is correlated to dental gold
  • 2002
  • Ingår i: Acta Dermato-Venereologica. - : Acta Dermato-Venereologica. - 1651-2057 .- 0001-5555. ; 82:1, s. 41-44
  • Tidskriftsartikel (refereegranskat)abstract
    • Questionnaire studies have indicated that patients with dental gold will more frequently have contact allergy to gold. This study aimed at investigating the relationship between contact allergy to gold and the presence and amount of dental gold alloys. A total of 102 patients were referred for patch testing because of suspicion of contact allergy. Patch tests were performed with gold sodium thiosulphate 2% and 5%. The patients underwent an oral clinical and radiological examination. Contact allergy to gold was recorded in 30.4% of the patients, and of these 74.2% had dental gold (p=0.009). A significant correlation was found between the amount of gold surfaces and contact allergy to gold (p=0.008), but there was no statistical relationship to oral lesions. It is concluded that there is a positive relationship between contact allergy to gold and presence and amount of dental gold alloys.
  •  
9.
  • Ahlgren, Camilla, et al. (författare)
  • The necessity of a test reading after 1 week to detect late positive patch test reactions in patients with oral lichen lesions
  • 2014
  • Ingår i: Clinical Oral Investigations. - : Springer. - 1432-6981 .- 1436-3771. ; 18:5, s. 1525-1531
  • Tidskriftsartikel (refereegranskat)abstract
    • Establishing the clinical relevance of contact allergy to dental materials in patients with oral lichen lesions (OLL) may be difficult, and tests are often read only on day 3 or day 4; also, concentration of the tested allergens may vary. Several studies on dermatitis patients have shown that additional positive patch test reactions can be found after day 4. Therefore, the aim of the present study was to analyse the frequency of late positive reactions to potential allergens in patients with OLL. Eighty-three of 96 consecutive patients with biopsy-verified OLL were patch-tested with a recently developed lichen series. The patches were removed after 48 h and reactions read 3 and 7 days after application. A total of 129 contact allergies were found, and 26 (20.2 %) of the allergic reactions in 23 patients were seen on day 7 only. The 25.2 % increase in positive test reactions with an additional reading on day 7 in addition to day 3 was statistically significant. Metals were the substances with the highest frequency of late positive reactions. Patients with OLL cannot be considered properly investigated with regard to contact allergy, unless the testing has been performed with mandatory readings on day 3 (or day 4) and day 7. Late patch test readings are crucial in order to elucidate the role of contact allergy to dental materials in the aetiology of OLL.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 30

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy