SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Darweesh M) "

Sökning: WFRF:(Darweesh M)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Thomas, HS, et al. (författare)
  • 2019
  • swepub:Mat__t
  •  
2.
  •  
3.
  • Ademuyiwa, Adesoji O., et al. (författare)
  • Determinants of morbidity and mortality following emergency abdominal surgery in children in low-income and middle-income countries
  • 2016
  • Ingår i: BMJ Global Health. - : BMJ Publishing Group Ltd. - 2059-7908. ; 1:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Child health is a key priority on the global health agenda, yet the provision of essential and emergency surgery in children is patchy in resource-poor regions. This study was aimed to determine the mortality risk for emergency abdominal paediatric surgery in low-income countries globally.Methods: Multicentre, international, prospective, cohort study. Self-selected surgical units performing emergency abdominal surgery submitted prespecified data for consecutive children aged <16 years during a 2-week period between July and December 2014. The United Nation's Human Development Index (HDI) was used to stratify countries. The main outcome measure was 30-day postoperative mortality, analysed by multilevel logistic regression.Results: This study included 1409 patients from 253 centres in 43 countries; 282 children were under 2 years of age. Among them, 265 (18.8%) were from low-HDI, 450 (31.9%) from middle-HDI and 694 (49.3%) from high-HDI countries. The most common operations performed were appendectomy, small bowel resection, pyloromyotomy and correction of intussusception. After adjustment for patient and hospital risk factors, child mortality at 30 days was significantly higher in low-HDI (adjusted OR 7.14 (95% CI 2.52 to 20.23), p<0.001) and middle-HDI (4.42 (1.44 to 13.56), p=0.009) countries compared with high-HDI countries, translating to 40 excess deaths per 1000 procedures performed.Conclusions: Adjusted mortality in children following emergency abdominal surgery may be as high as 7 times greater in low-HDI and middle-HDI countries compared with high-HDI countries. Effective provision of emergency essential surgery should be a key priority for global child health agendas.
  •  
4.
  • Chibnik, L. B., et al. (författare)
  • Trends in the incidence of dementia: design and methods in the Alzheimer Cohorts Consortium
  • 2017
  • Ingår i: European Journal of Epidemiology. - : Springer Science and Business Media LLC. - 0393-2990 .- 1573-7284. ; 32:10, s. 931-938
  • Tidskriftsartikel (refereegranskat)abstract
    • Several studies have reported a decline in incidence of dementia which may have large implications for the projected burden of disease, and provide important guidance to preventive efforts. However, reports are conflicting or inconclusive with regard to the impact of gender and education with underlying causes of a presumed declining trend remaining largely unidentified. The Alzheimer Cohorts Consortium aggregates data from nine international population-based cohorts to determine changes in the incidence of dementia since 1990. We will employ Poisson regression models to calculate incidence rates in each cohort and Cox proportional hazard regression to compare 5-year cumulative hazards across study-specific epochs. Finally, we will meta-analyse changes per decade across cohorts, and repeat all analysis stratified by sex, education and APOE genotype. In all cohorts combined, there are data on almost 69,000 people at risk of dementia with the range of follow-up years between 2 and 27. The average age at baseline is similar across cohorts ranging between 72 and 77. Uniting a wide range of disease-specific and methodological expertise in research teams, the first analyses within the Alzheimer Cohorts Consortium are underway to tackle outstanding challenges in the assessment of time-trends in dementia occurrence.
  •  
5.
  • Wolters, Frank J, et al. (författare)
  • Twenty-seven-year time trends in dementia incidence in Europe and the United States: The Alzheimer Cohorts Consortium.
  • 2020
  • Ingår i: Neurology. - 1526-632X. ; 95:5
  • Tidskriftsartikel (refereegranskat)abstract
    • To determine changes in the incidence of dementia between 1988 and 2015.This analysis was performed in aggregated data from individuals >65 years of age in 7 population-based cohort studies in the United States and Europe from the Alzheimer Cohort Consortium. First, we calculated age- and sex-specific incidence rates for all-cause dementia, and then defined nonoverlapping 5-year epochs within each study to determine trends in incidence. Estimates of change per 10-year interval were pooled and results are presented combined and stratified by sex.Of 49,202 individuals, 4,253 (8.6%) developed dementia. The incidence rate of dementia increased with age, similarly for women and men, ranging from about 4 per 1,000 person-years in individuals aged 65-69 years to 65 per 1,000 person-years for those aged 85-89 years. The incidence rate of dementia declined by 13% per calendar decade (95% confidence interval [CI], 7%-19%), consistently across studies, and somewhat more pronouncedly in men than in women (24% [95% CI 14%-32%] vs 8% [0%-15%]).The incidence rate of dementia in Europe and North America has declined by 13% per decade over the past 25 years, consistently across studies. Incidence is similar for men and women, although declines were somewhat more profound in men. These observations call for sustained efforts to finding the causes for this decline, as well as determining their validity in geographically and ethnically diverse populations.
  •  
6.
  • Alanazi, Ahmed Z., et al. (författare)
  • A novel disposable ultrasensitive sensor based on nanosized ceria uniformly loaded carbon nanofiber nanoceramic film wrapped on pencil graphite rods for electrocatalytic monitoring of a tyrosine kinase inhibitor capmatinib
  • 2024
  • Ingår i: Talanta. - : Elsevier. - 0039-9140 .- 1873-3573. ; 279
  • Tidskriftsartikel (refereegranskat)abstract
    • For the first time, we introduce a novel disposable and ultrasensitive sensing electrode made up of nanosized ceria uniformly loaded carbon nanofibers (CeNPs@CNF) sol-gel nanoceramic film (CF) wrapped on eco-friendly and inexpensive pencil graphite rods (PGRs) to explore their electro-catalytic detection of the anticancer drug capmatinib (CMB). The as-prepared CeNPs@CNF hybrid nanocomposite was described by XRD, SEM, TEM, HRTEM, and EDX analysis. The CV study clearly demonstrated that, the disposable CeNPs@CNF-CF/PGRE sensor exhibited excellent redox activities in the ideal probe [Fe(CN)(6)](3-/4-). Due to the outstanding electrochemical properties, larger electrochemically active surface area, and tremendous electro-catalytic activity of CeNPs@CNF, the reduction current of CMB on the CeNPs@CNF-CF/PGRE sensor is considerably higher than that of bare PGRE. The detection conditions, such as supporting electrolyte, pH of the buffer solution, amount of modifier, adsorption potential, and time, were studied and optimized. The sensing platform demonstrated high sensitivity (1.2 mu A nM(-1) cm(-2)), an ultralow detection limit (0.6 nM), and a wide linear range of 2.0 nM-400 nM of CMB compared to the bare PGRE. Additionally, the CeNPs@CNF-CF/PGRE sensor showed high selectivity, stability, and simple operation, which provided a promising alternative tool for fast detection of CMB in human body fluids with good recoveries.
  •  
7.
  • El-Wekil, Mohamed M., et al. (författare)
  • An innovative dual recognition aptasensor for specific detection of Staphylococcus aureus based on Au/Fe3O4 binary hybrid
  • 2022
  • Ingår i: Scientific Reports. - : Springer Nature. - 2045-2322. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Pathogenic bacteria cause disease outbreaks and threaten human health, prompting the research on advanced detection assays. Herein, we developed a selective molecular imprinted aptasensor for sensitive and prompt quantitation of Staphylococcus aureus (S. aureus) bacteria. The aptasensor was constructed by immobilization of aptamer on gold nanoparticles modified magnetic nanoparticles (apt-AuNPs@ Fe3O4). A functional monomer (o-phenylenediamine, o-phen) was electro-polymerized on the surface of the as-synthesized nanocomposite in the presence of a template (S. aureus). After removing S. aureus, the formed imprinted sites were available to extract pathogenic bacteria from complicated matrices. The surface morphology of the as-fabricated nanocomposites was characterized using different spectroscopic and electrochemical methods. Moreover, we thoroughly evaluated factors affecting the synthesis and determination procedures. The molecular imprinted aptasensor exhibited a wide linear range of 10(1)-10(7) CFU mL(-1) with a Limit of Detection, LOD (signal to noise = 3) of 1 CFU mL(-1). The aptasensor detected S. aureus in milk, conduit water, and apple juice samples with good recoveries % and satisfactory relative standard deviations (RSDs %) values.
  •  
8.
  • El-Wekil, Mohamed M., et al. (författare)
  • Enzyme-free and label-free strategy for electrochemical oxaliplatin aptasensing by using rGO/MWCNTs loaded with AuPd nanoparticles as signal probes and electro-catalytic enhancers
  • 2020
  • Ingår i: Talanta. - : Elsevier BV. - 0039-9140 .- 1873-3573. ; 217
  • Tidskriftsartikel (refereegranskat)abstract
    • An innovative label free electrochemical aptasensor was developed for the analysis of oxaliplatin (OXAL) for the first time. The DNA oligonucleotide (aptamer) was successfully fabricated, by covalently attaching the amino terminus of the functional DNA on the glassy carbon electrode (GCE) surface modified with reduced graphene oxide (rGO) and multi-walled carbon nanotubes (MWCNTs) loaded with AuPd nanoparticles (AuPd NPs@rGO/MWCNTs/GCE). The stepwise assembly process of aptasensor on AuPd NPs@rGO/MWCNTs/GCE was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The aptamer-OXAL complex formation led to inhibition the electron transfer of Fe(CN)63−/4- on the electrode interface, which was clearly observed by decreasing the peak current of the redox probe. Furthermore, we managed to quantitatively measure OXAL by adding different concentrations of OXAL, while monitoring the decrease of differential pulse voltammogram (DPV) responses of the redox probe. Under the optimized conditions, the electrochemical aptasensor exhibited a linear range of 0.1–170.0 nmol L−1 with LOD of 60.0 pmol L−1. Next, we successfully applied the aptasensor calibrated system to determine OXAL in pharmaceutical injection and human biological samples.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy