SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Gatu Johnson M) ;pers:(Murari A)"

Search: WFRF:(Gatu Johnson M) > Murari A

  • Result 1-8 of 8
Sort/group result
   
EnumerationReferenceCoverFind
1.
  •  
2.
  •  
3.
  •  
4.
  • Kiptily, V., et al. (author)
  • Doppler broadening of gamma ray lines and fast ion distribution in JET plasmas
  • 2010
  • In: Nuclear Fusion. - : IOP Publishing. - 0029-5515 .- 1741-4326. ; 50:8, s. 084001-
  • Journal article (peer-reviewed)abstract
    • The Doppler broadening of individual γ-ray lines was measured with a high purity germanium detector in JET plasma experiments. High-resolution γ-ray spectrometry of nuclear reactions between energetic D, 3 He and 4 He ions accelerated by ion cyclotron resonance heating and main plasma impurities such as carbon and beryllium has been used. The nuclear reactions giving rise to γ-rays have been identified and an effective temperature of the heated ions has been obtained in JET discharges. This technique could be used for fast ion and fusion alpha-particle studies in ITER.
  •  
5.
  • Murari, A., et al. (author)
  • New developments in the diagnostics for the fusion products on JET in preparation for ITER, (invited)
  • 2010
  • In: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 81:10, s. 10E136-
  • Journal article (peer-reviewed)abstract
    • Notwithstanding the advances of the past decades, significant developments are still needed to satisfactorily diagnose "burning plasmas." D-T plasmas indeed require a series of additional measurements for the optimization and control of the configuration: the 14 MeV neutrons, the isotopic composition of the main plasma, the helium ash, and the redistribution and losses of the alpha particles. Moreover a burning plasma environment is in general much more hostile for diagnostics than purely deuterium plasmas. Therefore, in addition to the development and refinement of new measuring techniques, technological advances are also indispensable for the proper characterization of the next generation of devices. On JET an integrated program of diagnostic developments, for JET future and in preparation for ITER, has been pursued and many new results are now available. In the field of neutron detection, the neutron spectra are now routinely measured in the energy range of 1-18 MeV by a time of flight spectrometer and they have allowed studying the effects of rf heating on the fast ions. A new analysis method for the interpretation of the neutron cameras measurements has been refined and applied to the data of the last trace tritium campaign (TTE). With regard to technological upgrades, chemical vapor deposition diamond detectors have been qualified both as neutron counters and as neutron spectrometers, with a potential energy resolution of about one percent. The in situ calibration of the neutron diagnostics, in preparation for the operation with the ITER-like wall, is also promoting important technological developments. With regard to the fast particles, for the first time the temperature of the fast particle tails has been obtained with a new high purity Germanium detector measuring the gamma emission spectrum from the plasma. The effects of toroidal Alfven eigenmodes modes and various MHD instabilities on the confinement of the fast particles have been determined with a combination of gamma ray cameras, neutral particle analyzers, scintillator probe, and Faraday cups. From a more technological perspective, various neutron filters have been tested to allow measurement of the gamma ray emission also at high level of neutron yield.
  •  
6.
  • Nocente, M., et al. (author)
  • High-resolution gamma ray spectroscopy measurements of the fast ion energy distribution in JET He-4 plasmas
  • 2012
  • In: Nuclear Fusion. - : IOP Publishing. - 0029-5515 .- 1741-4326. ; 52:6, s. 063009-
  • Journal article (peer-reviewed)abstract
    • High-resolution gamma-ray measurements were carried out on the Joint European Torus (JET) in an experiment aimed at accelerating He-4 ions in the MeV range by coupling third harmonic radio frequency heating to an injected He-4 beam. For the first time, Doppler broadening of gamma-ray peaks from the C-12(d, p gamma)C-13 and Be-9(alpha, n gamma)C-12 reactions was observed and interpreted with dedicated Monte Carlo codes based on the detailed nuclear physics of the processes. Information on the confined He-4 and deuteron energy distribution was inferred, and confined He-4 ions with energies as high as 6 MeV were assessed. A signature of MHD activity in gamma-ray traces was also detected. The reported results have a bearing on diagnostics for fast ions in the MeV range in next step fusion devices.
  •  
7.
  •  
8.
  • Gatu Johnson, Maria, et al. (author)
  • Modelling and TOFOR measurements of scattered neutrons at JET
  • 2010
  • In: Plasma Physics and Controlled Fusion. - : IOP Publishing. - 0741-3335 .- 1361-6587. ; 52:8, s. 085002-
  • Journal article (peer-reviewed)abstract
    • In this paper, the scattered and direct neutron fluxes in the line of sight (LOS) of the TOFOR neutron spectrometer at JET are simulated and the simulations compared with measurement results. The Monte Carlo code MCNPX is used in the simulations, with a vessel material composition obtained from the JET drawing office and neutron emission profiles calculated from TRANSP simulations of beam ion density profiles. The MCNPX simulations show that the material composition of the scattering wall has a large effect on the shape of the scattered neutron spectrum. Neutron source profile shapes as well as radial and vertical source displacements in the TOFOR LOS are shown to only marginally affect the scatter, while having a larger impact on the direct neutron flux. A matrix of simulated scatter spectra for mono-energetic source neutrons is created which is folded with an approximation of the source spectrum for each JET pulse studied to obtain a scatter component for use in the data analysis. The scatter components thus obtained are shown to describe the measured data. It is also demonstrated that the scattered flux is approximately constant relative to the total neutron yield as measured with the JET fission chambers, while there is a larger spread in the direct flux, consistent with simulations. The simulated effect on the integrated scattered/direct ratio of an increase with movements outward along the radial direction and a drop at higher values of the vertical plasma position is also reproduced in the measurements. Finally, the quantitative agreement found in scatter/direct ratios between simulations (0.185 ± 0.005) and measurements (0.187 ± 0.050) serves as a solid benchmark of the MCNPX model used.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-8 of 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view