SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Giannitsis Evangelos) ;pers:(Verschuren Franck)"

Sökning: WFRF:(Giannitsis Evangelos) > Verschuren Franck

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Body, Richard, et al. (författare)
  • The Use of Very Low Concentrations of High-sensitivity Troponin T to Rule Out Acute Myocardial Infarction Using a Single Blood Test
  • 2016
  • Ingår i: Academic Emergency Medicine. - : Wiley. - 1069-6563 .- 1553-2712. ; 23:9, s. 1005-1013
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Recent single-center and retrospective studies suggest that acute myocardial infarction (AMI) could be immediately excluded without serial sampling in patients with initial high-sensitivity cardiac troponin T (hs-cTnT) levels below the limit of detection (LoD) of the assay and no electrocardiogram (ECG) ischemia. Objective: We aimed to determine the external validity of those findings in a multicenter study at 12 sites in nine countries. Methods: TRAPID-AMI was a prospective diagnostic cohort study including patients with suspected cardiac chest pain within 6 hours of peak symptoms. Blood drawn on arrival was centrally tested for hs-cTnT (Roche; 99th percentile = 14 ng/L, LoD = 5 ng/L). All patients underwent serial troponin sampling over 4-14 hours. The primary outcome, prevalent AMI, was adjudicated based on sensitive troponin I (Siemens Ultra) levels. Major adverse cardiac events (MACE) including AMI, death, or rehospitalization for acute coronary syndrome with coronary revascularization were determined after 30 days. Results: We included 1,282 patients, of whom 213 (16.6%) had AMI and 231 (18.0%) developed MACE. Of 560 (43.7%) patients with initial hs-cTnT levels below the LoD, four (0.7%) had AMI. In total, 471 (36.7%) patients had both initial hs-cTnT levels below the LoD and no ECG ischemia. These patients had a 0.4% (n = 2) probability of AMI, giving 99.1% (95% confidence interval [CI] = 96.7% to 99.9%) sensitivity and 99.6% (95% CI = 98.5% to 100.0%) negative predictive value. The incidence of MACE in this group was 1.3% (95% CI = 0.5% to 2.8%). Conclusions: In the absence of ECG ischemia, the detection of very low concentrations of hs-cTnT at admission seems to allow rapid, safe exclusion of AMI in one-third of patients without serial sampling. This could be used alongside careful clinical assessment to help reduce unnecessary hospital admissions.
  •  
2.
  • McCord, James, et al. (författare)
  • Prognostic Utility of a Modified HEART Score in Chest Pain Patients in the Emergency Department
  • 2017
  • Ingår i: Circulation. Cardiovascular Quality and Outcomes. - : LIPPINCOTT WILLIAMS & WILKINS. - 1941-7713 .- 1941-7705. ; 10:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Background-The TRAPID-AMI trial study ( High-Sensitivity Troponin-T Assay for Rapid Rule-Out of Acute Myocardial Infarction) evaluated high-sensitivity cardiac troponin-T ( hs-cTnT) in a 1-hour acute myocardial infarction ( AMI) exclusion algorithm. Our study objective was to evaluate the prognostic utility of a modified HEART score ( m-HS) within this trial. Methods and Results-Twelve centers evaluated 1282 patients in the emergency department for possible AMI from 2011 to 2013. Measurements of hs-cTnT ( 99th percentile, 14 ng/L) were performed at 0, 1, 2, and 4 to 14 hours. Evaluation for major adverse cardiac events ( MACEs) occurred at 30 days ( death or AMI). Low-risk patients had an m-HS <= 3 and had either hs-cTnT<14 ng/L over serial testing or had AMI excluded by the 1-hour protocol. By the 1-hour protocol, 777 ( 60%) patients had an AMI excluded. Of those 777 patients, 515 ( 66.3%) patients had an m-HS <= 3, with 1 ( 0.2%) patient having a MACE, and 262 ( 33.7%) patients had an m-HS <= 4, with 6 ( 2.3%) patients having MACEs ( P=0.007). Over 4 to 14 hours, 661 patients had a hs-cTnT<14 ng/L. Of those 661 patients, 413 ( 62.5%) patients had an m-HS <= 3, with 1 ( 0.2%) patient having a MACE, and 248 ( 37.5%) patients had an m-HS >= 4, with 5 ( 2.0%) patients having MACEs ( P=0.03). Conclusions-Serial testing of hs-cTnT over 1 hour along with application of an m-HS identified a low-risk population that might be able to be directly discharged from the emergency department.
  •  
3.
  • McCord, James, et al. (författare)
  • Symptoms Predictive of Acute Myocardial Infarction in the Troponin Era : Analysis From the TRAPID-AMI Study.
  • 2019
  • Ingår i: Critical Pathways in Cardiology. - 1535-282X .- 1535-2811. ; 18:1, s. 10-15
  • Tidskriftsartikel (refereegranskat)abstract
    • The TRAPID-AMI (High Sensitivity Cardiac Troponin T assay for rapid Rule-out of Acute Myocardial Infarction) study evaluated a rapid "rule-out" acute myocardial infarction (AMI). We evaluated what symptoms were associated with AMI as part of a substudy of TRAPID-AMI. There were 1282 patients evaluated from 12 centers in Europe, the United States of America, and Australia from 2011 to 2013. Multiple symptom variables were prospectively obtained and evaluated for association with the final diagnosis of AMI. Multivariate logistic regression analysis was done, and odds ratios (OR) were calculated. There were 213/1282 (17%) AMIs. Four independent predictors for the diagnosis of AMI were identified: radiation to right arm or shoulder [OR = 3.0; confidence interval (CI): 1.8-5.0], chest pressure (OR = 2.5; CI: 1.3-4.6), worsened by physical activity (OR = 1.7; CI: 1.2-2.5), and radiation to left arm or shoulder (OR = 1.7; CI: 1.1-2.4). In the entire group, 131 (10%) had radiation to right arm or shoulder, 897 (70%) had chest pressure, 385 (30%) worsened with physical activity, and 448 (35%) had radiation to left arm or shoulder. Duration of symptoms was not predictive of AMI. There were no symptoms predictive of non-AMI. Relationship between AMI size and symptoms was also studied. For 213 AMI patients, cardiac troponins I values were divided into 4 quartiles. Symptoms including pulling chest pain, supramammillary right location, and right arm/shoulder radiation were significantly more likely to occur in patients with larger AMIs. In a large multicenter trial, only 4 symptoms were associated with the diagnosis of AMI, and no symptoms that were associated with a non-AMI diagnosis.
  •  
4.
  • Mueller, Christian, et al. (författare)
  • Multicenter Evaluation of a 0-Hour/1-Hour Algorithm in the Diagnosis of Myocardial Infarction With High-Sensitivity Cardiac Troponin T
  • 2016
  • Ingår i: Annals of Emergency Medicine. - : Elsevier BV. - 0196-0644 .- 1097-6760. ; 68:1, s. 76-87
  • Tidskriftsartikel (refereegranskat)abstract
    • Study objective: We aim to prospectively validate the diagnostic accuracy of the recently developed 0-h/1-h algorithm, using high-sensitivity cardiac troponin T (hs-cTnT) for the early rule-out and rule-in of acute myocardial infarction. Methods: We enrolled patients presenting with suspected acute myocardial infarction and recent (<6 hours) onset of symptoms to the emergency department in a global multicenter diagnostic study. Hs-cTnT (Roche Diagnostics) and sensitive cardiac troponin I (Siemens Healthcare) were measured at presentation and after 1 hour, 2 hours, and 4 to 14 hours in a central laboratory. Patient triage according to the predefined hs-cTnT 0-hour/1-hour algorithm (hs-cTnT beloow 12 ng/L and Delta 1 hour below 3 ng/L to rule out; hs-cTnT at least 52 ng/L r Delta 1 hour at least 5 ng/L to rule in; remaining patients to the "observational zone") was compared against a centrally adjudicated final diagnosis by 2 independent cardiologists (reference standard). The final diagnosis was based on all available information, including coronary angiography and echocardiography results, follow-up data, and serial measurements of sensitive cardiac troponin I, whereas adjudicators remained blinded to hs-cTnT. Results: Among 1,282 patients enrolled, acute myocardial infarction was the final diagnosis for 213 (16.6%) patients. Applying the hs-cTnT 0-hour/1-hour algorithm, 813 (63.4%) patients were classified as rule out, 184 (14.4%) were classified as rule in, and 285 (22.2%) were triaged to the observational zone. This resulted in a negative predictive value and sensitivity for acute myocardial infarction of 99.1% (95% confidence interval [CI] 98.2% to 99.7%) and 96.7% (95% CI 93.4% to 98.7%) in the rule-out zone (7 patients with false-negative results), a positive predictive value and specificity for acute myocardial infarction of 77.2% (95% CI 70.4% to 83.0%) and 96.1% (95% CI 94.7% to 97.2%) in the rule-in zone, and a prevalence of acute myocardial infarction of 22.5% in the observational zone. Conclusion: The hs-cTnT 0-hour/1-hour algorithm performs well for early rule-out and rule-in of acute myocardial infarction.
  •  
5.
  • Mueller-Hennessen, Matthias, et al. (författare)
  • Combined testing of copeptin and high-sensitivity cardiac troponin T at presentation in comparison to other algorithms for rapid rule-out of acute myocardial infarction
  • 2019
  • Ingår i: International Journal of Cardiology. - : Elsevier BV. - 0167-5273 .- 1874-1754. ; 276, s. 261-267
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: We aimed to directly compare the diagnostic and prognostic performance of a dual maker strategy (DMS) with combined testing of copeptin and high-sensitivity (hs) cardiac troponin T (cTnT) at time of presentation with other algorithms for rapid rule-out of acute myocardial infarction (AMI).METHODS: 922 patients presenting to the emergency department with suspected AMI and available baseline copeptin measurements qualified for the present TRAPID-AMI substudy. Diagnostic measures using the DMS (copeptin <10, <14 or < 20 pmol/L and hs-cTnT≤14 ng/L), the 1 h-algorithm (hs-cTnT<12 ng/L and change <3 ng/L at 1 h), as well as the hs-cTnT limit-of-blank (LoB, <3 ng/L) and -detection (LoD, <5 ng/L) were compared. Outcomes were assessed as combined end-points of death and myocardial re-infarction.RESULTS: True-negative rule-out using the DMS could be achieved in 50.9%-62.3% of all patients compared to 35.0%, 45.3% and 64.5% using LoB, LoD or the 1 h-algorithm, respectively. The DMS showed NPVs of 98.1%-98.3% compared to 99.2% for the 1 h-algorithm, 99.4% for the LoB and 99.3% for the LoD. Sensitivities were 93.5%-94.8%, as well as 96.8%, 98.7% and 98.1%, respectively. Addition of clinical low-risk criteria such as a HEART-score ≤ 3 to the DMS resulted in NPVs and sensitivities of 100% with a true-negative rule-out to 33.8%-41.6%. Rates of the combined end-point of death/MI within 30 days ranged between 0.2% and 0.3% for all fast-rule-out protocols.CONCLUSION: Depending on the applied copeptin cut-off and addition of clinical low-risk criteria, the DMS might be an alternative to the hs-cTn-only-based algorithms for rapid AMI rule-out with comparable diagnostic measures and outcomes.
  •  
6.
  • Mueller-Hennessen, Matthias, et al. (författare)
  • Diagnostic and prognostic implications using age- and gender-specific cut-offs for high-sensitivity cardiac troponin T - Sub-analysis from the TRAPID-AMI study
  • 2016
  • Ingår i: International Journal of Cardiology. - : Elsevier BV. - 0167-5273 .- 1874-1754. ; 209, s. 26-33
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: To evaluate the impact of age-and gender-specific cut-offs for high-sensitivity cardiac troponin T (hs-cTnT) compared to the general 99th percentile hs-cTnT cut-off on diagnosis and prognosis of acute myocardial infarction (AMI).Methods: 1282 unselected patients presenting to the emergency department with suspected AMI were enrolled as part of the TRAPID-AMI study. In the present sub-analysis, reclassification of AMI diagnosis was performed by comparing the general hs-cTnT cut-off of 14 ng/L to previously proposed age-and gender-dependent hs-cTnT 99th percentile cut-offs (28 ng/L for >= 65 years, 9 ng/L for female and 15.5 ng/L for male patients). Patients were further clinically adjudicated into acute coronary syndrome (ACS) and non-ACS.Results: For patients >= 65 years, application of age-specified cut-offs resulted in a decrease of AMI from 29.8% to 18.3% in the entire cohort (n = 557) and 54.7% to 40.9% in the ACS subcohort (n = 225). Using gender-specific cut-offs, AMI-rate increased from 16.6% to 22.6% (entire cohort, n = 477) and 62.6% to 71.7% (ACS subcohort, n = 99) in women, whereas in men, rates decreased from 23.1% to 21.1% (entire cohort, n = 805) and 48.8% to 45.9% (ACS, n = 281), respectively. Age-specified cut-offs significantly reclassified patients for outcomes of 1-month and 3-month mortality in the entire and ACS cohort (14.2% net reclassification improvement, p < 0.001, respectively). Contrary, no significant differences in outcomes could be found using gender-specific cut-offs.Conclusions: While influence of gender-specific hs-cTnT cut-offs on diagnostic and prognostic reclassification was only modest in patients with suspected AMI, age-specific cut-offs showed a significant impact and may be considered for further validation.
  •  
7.
  • Nowak, Richard, et al. (författare)
  • High sensitivity cardiac troponin T in patients not having an acute coronary syndrome : results from the TRAPID-AMI study
  • 2017
  • Ingår i: Biomarkers. - 1354-750X .- 1366-5804. ; 22:8, s. 709-714
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To describe the baseline, 1hr and delta high sensitivity cardiac troponin (hs-cTnT) values in patients with suspected acute myocardial infarction (AMI) but without a final acute coronary syndrome (ACS) diagnosis.Materials and methods: hs-cTnT assay for RAPID rule out of acute myocardial infarction (TRAPID-AMI) was a prospective diagnostic trial that enrolled emergency department (ED) patients with suspected AMI. Final patient diagnoses were adjudicated by a clinical events committee and subjects placed in different clinical groups: AMI, unstable angina, non-ACS cardiac, non-cardiac and unknown origin. The baseline, 1hr and delta hs-cTnT values were analysed in the 902 non-ACS patients.Results: Amongst the 1282 studied the patient groups were 213 (17%) AMI, 167 (13%) unstable angina, 113 (9%) non-ACS cardiac, 288 (22%) non-cardiac and 501 (39%) unknown origin. The hs-cTnT values in the non-cardiac and unknown origin groups were combined. The median hs-cTnT values (ng/L) were higher (p<0.001) in the non-ACS cardiac compared to the non-cardiac/unknown origin group at baseline (11.8,<5) and 1hr (12.3,<5). Their negative predictive values were 0.955 (baseline) and 0.954 (1hr) for predicting non-ACS cardiac versus non-cardiac/unknown origin diagnoses.Conclusions: Hs-cTnT may help predict whether non-ACS ED patients have a final non-ACS cardiac or non-cardiac/unknown origin diagnoses.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy