Correlation between Stated and Measured Concentrations of Acrylate and Methacrylate Allergens in Patch-Test Preparations
-
- Goon, Anthony (författare)
- Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
-
- Bruze, Magnus (författare)
- Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
-
- Zimerson, Erik (författare)
- Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
-
visa fler...
-
- Sörensen, Östen (författare)
- Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
-
Goh, Chee-Leok (författare)
-
Koh, David Soo-Quee (författare)
-
- Isaksson, Marléne (författare)
- Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
-
visa färre...
-
(creator_code:org_t)
- Mary Ann Liebert Inc, 2011
- 2011
- Engelska.
-
Ingår i: Dermatitis. - : Mary Ann Liebert Inc. - 1710-3568. ; 22:1, s. 27-32
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.2...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background: Contact allergy to acrylates and methacrylates is not uncommon. The allergy is confirmed by patch-testing patients with commercial patch-test preparations. Objective: To investigate acrylate and methacrylate allergens used for patch testing in nine different dermatology departments from Europe, America, Asia, and Australia. Methods: The acrylate and methacrylate (methyl methacrylate, 2-hydroxypropyl acrylate, 2-hydroxyethyl methacrylate, ethylene glycol dimethacrylate, and triethylene glycol diacrylate) allergen samples were analyzed with high-performance liquid chromatography to measure the allergen content. Results: Variation in measured versus stated concentrations was seen in these samples. The ratio of measured to stated concentrations ranged from 0.11 to 1.1. Only 22 (63%) of 35 samples were within the arbitrary acceptable limits of 80 to 120% of the stated concentrations. Conclusion: The results may have implications for individual diagnosis and prevention and when test results from various centers are compared.