SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gonçalo Margarida) ;pers:(Nixon Rosemary)"

Sökning: WFRF:(Gonçalo Margarida) > Nixon Rosemary

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bruze, Magnus, et al. (författare)
  • Contact Allergy to Fragrance Mix II and Hydroxyisohexyl 3-Cyclohexene Carboxaldehyde : A Retrospective Study by International Contact Dermatitis Research Group
  • 2020
  • Ingår i: Dermatitis : contact, atopic, occupational, drug. - 1710-3568. ; 31:4, s. 268-271
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Fragrance mix II (FM II) is included in the baseline patch test series recommended by the International Contact Dermatitis Research Group (ICDRG). Hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC) is the most important sensitizer of the 6 fragrance materials included in FM II. Besides being a part of FM II, HICC is also tested separately in the ICDRG baseline series. OBJECTIVES: The aim of the study was to investigate the prevalence of contact allergy to FM II and HICC in 2012-2016 with a focus on simultaneous reactions and the percentage of missed contact allergy to HICC provided that only FM II had been tested. PATIENTS AND METHODS: A total of 25,019 consecutive dermatitis patients in 13 dermatology clinics representing 12 countries in 5 continents were patch tested with FM II and HICC in the baseline series. RESULTS: Contact allergy to FM II and HICC was found in 3.9% and 1.6%, respectively. For FM II, the frequency varied from 1.5% to 7.6% in different centers. The corresponding range for HICC was 0.2% to 3.6%. Simultaneous contact allergy to FM II and HICC was noted in 1.4% with the range 0.2% to 2.6%. Seventy-seven patients (0.31%) with contact allergy to HICC did not test positively to FM II. The range for missed HICC allergy by testing only FM II in the different centers would be 0.04% to 0.74%. The ratio between the contact allergy rates for FM II and HICC was similar for all centers, except for Montreal having significantly more contact allergy to FM II than to HICC. CONCLUSIONS: The frequency of missed contact allergy to HICC when testing only with FM II was less than 0.5%, therefore questioning the need to test HICC separately in the ICDRG baseline series.
  •  
2.
  •  
3.
  • Lejding, Tina, et al. (författare)
  • Analysis of Hexavalent Chromium in Cement Samples From Countries Within and Outside the EU : A Study From the International Contact Dermatitis Research Group
  • 2023
  • Ingår i: Dermatitis : contact, atopic, occupational, drug. - : Mary Ann Liebert Inc. - 1710-3568. ; 34:4, s. 323-328
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Allergic contact dermatitis (ACD) caused by hexavalent chromium (Cr(VI)) is often severe and difficult to treat. The content of Cr(VI) in cement can be reduced by, for example, addition of iron(II) sulfate. Since 2005 the content of Cr(VI) in cement is regulated in the EU Directive 2003/53/EC and must not exceed 2 ppm. Since this regulation came into force, ACD caused by cement has markedly been reduced. Objective: To investigate Cr(VI) and total chromium content in samples of cement from countries within and outside the EU. Methods: The members of the International Contact Dermatitis Research Group (ICDRG) were invited to participate in the study with the aim to collect cement samples from geographically different areas. The content of Cr(VI) in the samples was estimated by the diphenyl carbazide spot test, atomic absorption spectroscopy was used to assess the total chromium content. Results: Forty-five cement samples were analyzed, containing amounts of Cr(VI) from <0.1 to >70 ppm. Twenty-one samples contained >2 ppm Cr(VI), 24 contained less. Four of 17 samples from within the EU contained >2 ppm Cr(VI), that is, higher amounts than stipulated in the EU directive, as compared with 17 samples from countries outside the EU. Conclusion: In countries outside the EU, significantly more cement samples contained >2 ppm Cr(VI).
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy