SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Hattersley Andrew T) srt2:(2010-2014);lar1:(liu)"

Sökning: WFRF:(Hattersley Andrew T) > (2010-2014) > Linköpings universitet

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Besser, Rachel E J, et al. (författare)
  • Lessons From the Mixed-Meal Tolerance Test Use of 90-minute and fasting C-peptide in pediatric diabetes
  • 2013
  • Ingår i: Diabetes Care. - : American Diabetes Association. - 0149-5992 .- 1935-5548. ; 36:2, s. 195-201
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE-Mixed-meal tolerance test (MMTT) area under the curve C-peptide (AUC CP) is the gold-standard measure of endogenous insulin secretion in type 1 diabetes but is intensive and invasive to perform. The 90-minMMTT-stimulated CP andgt;= 0.2 nmol/L (90CP) is related to improved clinical outcomes, and CP andgt;= 0.1 nmol/L is the equivalent fasting measure (FCP). We assessed whether 90CP or FCP are alternatives to a full MMTT. less thanbrgreater than less thanbrgreater thanRESEARCH DESIGN AND METHODS-CP was measured during 1,334 MMTTs in 421 type 1 diabetes patients aged, 18 years at 3, 9, 18, 48, and 72 months duration. We assessed: 1) correlation between mean AUC CP and 90CP or FCP; 2) sensitivity and specificity of 90CP andgt;= 0.2 nmol/L and FCP andgt;= 0.1 nmol/L to detect peak CP andgt;= 0.2 nmol/L and the equivalent AUC CP; and 3) how the time taken to reach the CP peak varied with age of diagnosis and diabetes duration. less thanbrgreater than less thanbrgreater thanRESULTS-AUC CP was highly correlated to 90CP (r(s) = 0.96; P andlt; 0.0001) and strongly correlated to FCP (r(s) = 0.84; P andlt; 0.0001). AUC CP andgt;= 23 nmol/L/150 min was the equivalent cutoff for peak CP andgt;= 0.2 nmol/L (98% sensitivity/97% specificity). A 90CP andgt;= 0.2 nmol/L correctly classified 96% patients using AUC or peak CP, whereas FCP andgt;= 0.1 nmol/L classified 83 and 85% patients, respectively. There was only a small difference seen between peak and 90CP (median 0.02 nmol/L). The CP peak occurred earlier in patients with longer diabetes duration (6.1 min each 1-year increase in duration) and younger age (2.5 min each 1-year increase). less thanbrgreater than less thanbrgreater thanCONCLUSIONS-90CP is a highly sensitive and specific measure of AUC and peak CP in children and adolescents with type 1 diabetes and offers a practical alternative to a full MMTT. Diabetes Care 36:195-201, 2013
  •  
2.
  • Besser, Rachel E J, et al. (författare)
  • Urine C-Peptide Creatinine Ratio Is a Noninvasive Alternative to the Mixed-Meal Tolerance Test in Children and Adults With Type 1 Diabetes
  • 2011
  • Ingår i: DIABETES CARE. - : American Diabetes Association Inc. - 0149-5992 .- 1935-5548. ; 34:3, s. 607-609
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE-Stimulated serum C-peptide (sCP) during a mixed-meal tolerance test (MMTT) is the gold standard measure of endogenous insulin secretion, but practical issues limit its use. We assessed urine C-peptide creatinine ratio (UCPCR) as an alternative. RESEARCH DESIGN AND METHODS-Seventy-two type 1 diabetic patients (age of diagnosis median 14 years [interquartile range 10-22]; diabetes duration 6.5[2.3-32.7]) had an MMTT. sCP was collected at 90 min. Urine for UCPCR was collected at 120 min and following a home evening meal. RESULTS-MMTT 120-min UCPCR was highly correlated to 90-min sCP (r = 0.97; P andlt; 0.0001). UCPCR andgt;= 0.53 nmol/mmol had 94% sensitivity/100% specificity for significant endogenous insulin secretion (90-min sCP andgt;= 0.2 nmol/L). The 120-min postprandial evening meal UCPCR was highly correlated to 90-min sCP (r = 0.91; P andlt; 0.0001). UCPCR andgt;= 0.37 nmol/mmol had 84% sensitivity/97% specificity for sCP andgt;= 0.2 nmol/L. CONCLUSIONS-UCPCR testing is a sensitive and specific method for detecting insulin secretion. UCPCR may be a practical alternative to serum C-peptide testing, avoiding the need for inpatient investigation.
  •  
3.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy