SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kühn T) ;hsvcat:2"

Sökning: WFRF:(Kühn T) > Teknik

  • Resultat 1-10 av 10
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kuhn, D., et al. (författare)
  • Localised anodic oxidation of aluminium material using a continuous electrolyte jet
  • 2017
  • Ingår i: IOP Conference Series. - : Institute of Physics Publishing (IOPP).
  • Konferensbidrag (refereegranskat)abstract
    • Anodic oxidation of aluminium and its alloys is often used as protection against material wearout and corrosion. Therefore, anodic oxidation of aluminium is applied to produce functional oxide layers. The structure and properties of the oxide layers can be influenced by various factors. These factors include for example the properties of the substrate material, like alloy elements and heat treatment or process parameters, like operating temperature, electric parameters or the type of the used electrolyte. In order to avoid damage to the work-piece surface caused by covering materials in masking applications, to minimize the use of resources and to modify the surface in a targeted manner, the anodic oxidation has to be localised to partial areas. Within this study a proper alternative without preparing the substrate by a mask is investigated for generating locally limited anodic oxidation by using a continuous electrolyte jet. Therefore aluminium material EN AW 7075 is machined by applying a continuous electrolyte jet of oxalic acid. Experiments were carried out by varying process parameters like voltage or processing time. The realised oxide spots on the aluminium surface were investigated by optical microscopy, SEM and EDX line scanning. Furthermore, the dependencies of the oxide layer properties from the process parameters are shown.
  •  
2.
  • Pinaroli, G., et al. (författare)
  • PERCIVAL : Possible applications in X-ray micro-tomography
  • 2020
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 15:2
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray computed micro-tomography (μCT) is one of the most advanced and common non-destructive techniques in the field of medical imaging and material science. It allows recreating virtual models (3D models), without destroying the original objects, by measuring three-dimensional X-ray attenuation coefficient maps of samples on the (sub) micrometer scale. The quality of the images obtained using μCT is strongly dependent on the performance of the associated X-ray detector i.e. to the acquisition of information of the X-ray beam traversing the patient/sample being precise and accurate. Detectors for μCT have to meet the requirements of the specific tomography procedure in which they are going to be used. In general, the key parameters are high spatial resolution, high dynamic range, uniformity of response, high contrast sensitivity, fast acquisition readout and support of high frame rates. At present the detection devices in commercial μCT scanners are dominated by charge-coupled devices (CCD), photodiode arrays, CMOS acquisition circuits and more recently by hybrid pixel detectors. Monolithic CMOS imaging sensors, which offer reduced pixel sizes and low electronic noise, are certainly excellent candidates for μCT and may be used for the development of novel high-resolution imaging applications. The uses of monolithic CMOS based detectors such as the PERCIVAL detector are being recently explored for synchrotron and FEL applications. PERCIVAL was developed to operate in synchrotron and FEL facilities in the soft X-ray regime from 250 eV to 1 keV and it could offer all the aforementioned technical requirements needed in μCT experiments. In order to adapt the system for a typical tomography application, a scintillator is required, to convert incoming X-ray radiation (∼ tens of KeV) into visible light which may be detected with high efficiency. Such a taper-based scintillator was developed and mounted in front of the sensitive area of the PERCIVAL imager. In this presentation we will report the setup of the detector system and preliminary results of first μCTs of reference objects, which were performed in the TomoLab at ELETTRA. 
  •  
3.
  • Sedgwick, I., et al. (författare)
  • P2M : First Optical Characterisation Results of a 2MPixel CMOS Image Sensor for Soft X-Ray Detection
  • 2019
  • Ingår i: 2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC). - : IEEE. - 9781728141640
  • Konferensbidrag (refereegranskat)abstract
    • High brilliance synchrotrons and FELs require high performing detector systems to realise their full potential. High dynamic range, low noise and high frame rate are all of great importance. In this paper we present first optical characterization results of the P2M CMOS sensor, designed for soft X-ray detection at such facilities. Previous work is summarised and an overview of the sensor is presented. Test results for the sensor's column-parallel ADC and readout chain are presented, and first test results for the pixel acquired using the Photon Transfer Curve (PTC) method are shown. Finally, an outline of future work is provided.
  •  
4.
  • Sieber, Maximilian, et al. (författare)
  • Downscaled anodic oxidation process for aluminium in oxalic acid
  • 2017
  • Ingår i: IOP Conference Series. - : Institute of Physics Publishing (IOPP).
  • Konferensbidrag (refereegranskat)abstract
    • The increasing multi-functionality of parts and assemblies in several fields of engineering demands, amongst others, highly functionalised surfaces. For the different applications, on the one hand, there is a need to scale up surface modification processes originating in the nano- and micro-scale. On the other hand, conventional macro-scale surface refinement methods offer a huge potential for application in the said nano- and micro-scale. The anodic oxidation process, which is established especially for aluminium and its alloys, allows the formation of oxide ceramic layers on the surface. The build-up of an oxide ceramic coating comes along with altered chemical, tribological and electrical surface properties. As a basis for further investigations regarding the use of the anodic oxidation process for micro-scale-manufacturing, the scale effects of oxalic acid anodising on commercially pure aluminium as well as on the AlZn5.5MgCu alloy are addressed in the present work. The focus is on the amount of oxide formed during a potentiostatic process in relation to the exchanged amount of charge. Further, the hardness of the coating as an integral measure to assess the porous oxide structure is approached by nano-indentation technique. 
  •  
5.
  • Wunderer, C. B., et al. (författare)
  • The Percival 2-Megapixel monolithic active pixel imager
  • 2019
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 14:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The peak brilliance reached by today's Free-Electron Laser and Synchrotron light sources requires photon detectors matching their output intensity and other characteristics in order to fully realize the sources' potential. The Pixellated Energy Resolving CMOS Imager, Versatile And Large (Percival) is a dedicated soft X-ray imager (0.25-1 keV) developed for this purpose by a collaboration of DESY, Rutherford Appleton Laboratory/STFC, Elettra Sincrotrone Trieste, Diamond Light Source, and Pohang Accelerator Laboratory. Following several generations of prototypes, the Percival "P2M" 2-Megapixel imager - a 4.5x5 cm monolithic, stitched sensor with an uninterrupted imaging area of 4x4 cm(2) (1408x1484 pixels of 27x27 mu m - was produced and has demonstrated basic functionality with a first-light image using visible light. It is currently being brought to full operation in a front-illuminated configuration. The readout system being commissioned in parallel has been developed specifically for this imager which will produce - at full 300 Hz frame rate - data at 20 Gbit/s. A first wafer with eight Percival P2M chips has undergone backthinning to enable soft X-ray detection. It has been diced and chips are currently being wirebonded. We summarize here the P2M system, the project status, and show the P2M sensor's first response to visible light.
  •  
6.
  • Frandsen, H. L., et al. (författare)
  • Accelerated creep in solid oxide fuel cell anode supports during reduction
  • 2016
  • Ingår i: Journal of Power Sources. - : Elsevier BV. - 0378-7753. ; 323, s. 78-89
  • Tidskriftsartikel (refereegranskat)abstract
    • To evaluate the reliability of solid oxide fuel cell (SOFC) stacks during operation, the stress field in the stack must be known. During operation the stress field will depend on time as creep processes relax stresses. The creep of reduced Ni-YSZ anode support at operating conditions has been studied previously. In this work a newly discovered creep phenomenon taking place during the reduction is reported. This relaxes stresses at a much higher rate (∼×104) than creep during operation. The phenomenon was studied both in three-point bending and uniaxial tension. Differences between the two measurements could be explained by newly observed stress promoted reduction. Finally, samples exposed to a small tensile stress (∼0.004 MPa) were observed to expand during reduction, which is in contradiction to previous literature. These observations suggest that release of internal residual stresses between the NiO and the YSZ phases occurs during reduction. The accelerated creep should practically eliminate any residual stress in the anode support in an SOFC stack, as has previously been indirectly observed. This phenomenon has to be taken into account both in the production of stacks and in the simulation of the stress field in a stack based on anode supported SOFCs.
  •  
7.
  • Fritze, Stefan, et al. (författare)
  • Elemental distribution and fracture properties of magnetron sputtered carbon supersaturated tungsten films
  • 2024
  • Ingår i: Surface & Coatings Technology. - : Elsevier BV. - 0257-8972 .- 1879-3347. ; 477
  • Tidskriftsartikel (refereegranskat)abstract
    • The combination of strength and toughness is a major driving force for alloy design of protective coatings, and nanocrystalline tungsten (W)-alloys have shown to be promising candidates for combining strength and toughness. Here we investigate the elemental distribution and the fracture toughness of carbon (C) alloyed W thin films prepared by non-reactive magnetron sputtering. W:C films with up to ~4 at.% C crystallize in a body-centered-cubic structure with a strong 〈hh0〉texture, and no additional carbide phases are observed in the diffraction pattern. Atom probe tomography and X-ray photoelectron spectroscopy confirmed the formation of such a supersaturated solid solution. The pure W film has a hardness ~13 GPa and the W:C films exhibit a peak hardness of ~24 GPa. In-situ micromechanical cantilever bending tests show that the fracture toughness decreases from ~4.5 MPa·m1/2 for the W film to ~3.1 MPa·m1/2 for W:C films. The results show that C can significantly enhance the hardness of W thin films while retaining a high fracture toughness.
  •  
8.
  • Karstens, Jens, et al. (författare)
  • Formation of the Figge Maar Seafloor Crater During the 1964 B1 Blowout in the German North Sea
  • 2022
  • Ingår i: Earth Science, Systems and Society. - : Frontiers Media SA. - 2634-730X. ; 2
  • Tidskriftsartikel (refereegranskat)abstract
    • In 1964, exploration drilling in the German Sector of the North Sea hit a gas pocket at ∼2900 m depth below the seafloor and triggered a blowout, which formed a 550 m-wide and up to 38 m deep seafloor crater now known as Figge Maar. Although seafloor craters formed by fluid flow are very common structures, little is known about their formation dynamics. Here, we present 2D reflection seismic, sediment echosounder, and multibeam echosounder data from three geoscientific surveys of the Figge Maar blowout crater, which are used to reconstruct its formation. Reflection seismic data support a scenario in which overpressured gas ascended first through the lower part of the borehole and then migrated along steeply inclined strata and faults towards the seafloor. The focused discharge of gas at the seafloor removed up to 4.8 Mt of sediments in the following weeks of vigorous venting. Eyewitness accounts document that the initial phase of crater formation was characterized by the eruptive expulsion of fluids and sediments cutting deep into the substrate. This was followed by a prolonged phase of sediment fluidization and redistribution widening the crater. After fluid discharge ceased, the Figge Maar acted as a sediment trap reducing the crater depth to ∼12 m relative to the surrounding seafloor in 2018, which corresponds to an average sedimentation rate of ∼22,000 m3/yr between 1995 and 2018. Hydroacoustic and geochemical data indicate that the Figge Maar nowadays emits primarily biogenic methane, predominantly during low tide. The formation of Figge Maar illustrates hazards related to the formation of secondary fluid pathways, which can bypass safety measures at the wellhead and are thus difficult to control. 
  •  
9.
  • Kuhn, Linda, et al. (författare)
  • Residents' perceptions following retrofitting of residential area outdoor lighting with LEDs
  • 2013
  • Ingår i: Lighting Research and Technology. - : SAGE Publications. - 1477-1535 .- 1477-0938. ; 45:5, s. 568-584
  • Tidskriftsartikel (refereegranskat)abstract
    • The use of light emitting diodes (LEDs) in outdoor lighting has energy-saving potential, but users' responses to this light source are largely unknown. An intervention study in two residential areas compared conventional lighting installations (high pressure sodium in Area 1 and high pressure mercury in Area 2) to a retrofitted LED-alternative regarding residents' perceptions of quality of light, visual accessibility and danger. Moreover, energy use was calculated. Residents' (N=60) visual accessibility improved and perceived danger remained low in both areas after retrofitting. In Area 2 the perceived quality of light increased, whereas in Area 1 the results were mixed. The retrofitted application reduced energy use by 41-76% and might be a feasible alternative to conventional outdoor lighting in relatively safe areas.
  •  
10.
  • Verdes, C., et al. (författare)
  • Pointing and temperature retrieval from millimeter-submillimeter limb soundings
  • 2002
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 107:16, s. 4299-
  • Tidskriftsartikel (refereegranskat)abstract
    • Passive microwave limb sounding instruments like the Millimeter-Wave Atmospheric Sounder (MAS) or the Microwave Limb Sounder (MLS) observe dedicated oxygen lines for the derivation of temperature and pointing information, since these quantities are essential for the quality of the retrieval of the trace gas mixing ratio. Emission lines of oxygen are chosen because the volume mixing ratio (VMR) profile is known. In this paper, we demonstrate the capabilities of a new and innovative method by means of which accurate temperature and pointing information can be gathered from other strong spectral features like ozone lines, without including accurate knowledge of the VMR profile of these species. For this purpose, retrievals from two observation bands with a bandwidth of about 10 GHz each, one including an oxygen line, have been compared. A full error analysis was performed with respect to critical instrument and model parameters, such as uncertainties in the antenna pattern, calibration uncertainties, random pointing error, baseline ripples, baseline discontinuities, and spectroscopic parameters. The applied inversion algorithm was the optimal estimation method. For the selected scenario and instrumental specifications we find that the retrieval of a pointing offset and the atmospheric temperature profile can be achieved with a good accuracy. The retrieval precision of the pointing offset is better than 24 m. The retrieval precision of the temperature profile is better than 2 K for altitudes ranging from 10 to 40 km. Systematic errors (due to model parameter uncertainties) are somewhat larger than these purely statistical errors. Investigations carried out for different atmospheric states or different instrumental specifications show similar results.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy