SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Kühn T) ;mspu:(researchreview)"

Search: WFRF:(Kühn T) > Research review

  • Result 1-8 of 8
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Schael, S, et al. (author)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • In: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Research review (peer-reviewed)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Schael, S., et al. (author)
  • Electroweak measurements in electron positron collisions at W-boson-pair energies at LEP
  • 2013
  • In: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 532:4, s. 119-244
  • Research review (peer-reviewed)abstract
    • Electroweak measurements performed with data taken at the electron positron collider LEP at CERN from 1995 to 2000 are reported. The combined data set considered in this report corresponds to a total luminosity of about 3 fb(-1) collected by the four LEP experiments ALEPH, DELPHI, 13 and OPAL, at centre-of-mass energies ranging from 130 GeV to 209 GeV. Combining the published results of the four LEP experiments, the measurements include total and differential cross-sections in photon-pair, fermion-pair and four-fermion production, the latter resulting from both double-resonant WW and ZZ production as well as singly resonant production. Total and differential cross-sections are measured precisely, providing a stringent test of the Standard Model at centre-of-mass energies never explored before in electron positron collisions. Final-state interaction effects in four-fermion production, such as those arising from colour reconnection and Bose Einstein correlations between the two W decay systems arising in WW production, are searched for and upper limits on the strength of possible effects are obtained. The data are used to determine fundamental properties of the W boson and the electroweak theory. Among others, the mass and width of the W boson, m(w) and Gamma(w), the branching fraction of W decays to hadrons, B(W -> had), and the trilinear gauge-boson self-couplings g(1)(Z), K-gamma and lambda(gamma), are determined to be: m(w) = 80.376 +/- 0.033 GeV Gamma(w) = 2.195 +/- 0.083 GeV B(W -> had) = 67.41 +/- 0.27% g(1)(Z) = 0.984(-0.020)(+0.018) K-gamma - 0.982 +/- 0.042 lambda(gamma) = 0.022 +/- 0.019. (C) 2013 Elsevier B.V. All rights reserved.
  •  
3.
  • Aamodt, K., et al. (author)
  • The ALICE experiment at the CERN LHC
  • 2008
  • In: Journal of Instrumentation. - 1748-0221. ; 3:S08002
  • Research review (peer-reviewed)abstract
    • ALICE (A Large Ion Collider Experiment) is a general-purpose, heavy-ion detector at the CERN LHC which focuses on QCD, the strong-interaction sector of the Standard Model. It is designed to address the physics of strongly interacting matter and the quark-gluon plasma at extreme values of energy density and temperature in nucleus-nucleus collisions. Besides running with Pb ions, the physics programme includes collisions with lighter ions, lower energy running and dedicated proton-nucleus runs. ALICE will also take data with proton beams at the top LHC energy to collect reference data for the heavy-ion programme and to address several QCD topics for which ALICE is complementary to the other LHC detectors. The ALICE detector has been built by a collaboration including currently over 1000 physicists and engineers from 105 Institutes in 30 countries, Its overall dimensions are 16 x 16 x 26 m(3) with a total weight of approximately 10 000 t. The experiment consists of 18 different detector systems each with its own specific technology choice and design constraints, driven both by the physics requirements and the experimental conditions expected at LHC. The most stringent design constraint is to cope with the extreme particle multiplicity anticipated in central Pb-Pb collisions. The different subsystems were optimized to provide high-momentum resolution as well as excellent Particle Identification (PID) over a broad range in momentum, up to the highest multiplicities predicted for LHC. This will allow for comprehensive studies of hadrons, electrons, muons, and photons produced in the collision of heavy nuclei. Most detector systems are scheduled to be installed and ready for data taking by mid-2008 when the LHC is scheduled to start operation, with the exception of parts of the Photon Spectrometer (PHOS), Transition Radiation Detector (TRD) and Electro Magnetic Calorimeter (EMCal). These detectors will be completed for the high-luminosity ion run expected in 2010. This paper describes in detail the detector components as installed for the first data taking in the summer of 2008.
  •  
4.
  • Abelev, B., et al. (author)
  • Performance of the ALICE experiment at the CERN LHC
  • 2014
  • In: International Journal of Modern Physics A. - 0217-751X. ; 29:24
  • Research review (peer-reviewed)abstract
    • ALICE is the heavy-ion experiment at the CERN Large Hadron Collider. The experiment continuously took data during the first physics campaign of the machine from fall 2009 until early 2013, using proton and lead-ion beams. In this paper we describe the running environment and the data handling procedures, and discuss the performance of the ALICE detectors and analysis methods for various physics observables.
  •  
5.
  • Biazar, C., et al. (author)
  • Cutaneous lupus erythematosus : First multicenter database analysis of 1002 patients from the European Society of Cutaneous Lupus Erythematosus (EUSCLE)
  • 2013
  • In: Autoimmunity Reviews. - : Elsevier BV. - 1568-9972 .- 1873-0183. ; 12:3, s. 444-454
  • Research review (peer-reviewed)abstract
    • In this prospective, cross-sectional, multicenter study, we assessed clinical and laboratory characteristics from patients with cutaneous lupus erythematosus (CLE) using the Core Set Questionnaire of the European Society of Cutaneous Lupus Erythematosus (EUSCLE). 1002 (768 females, 234 males) patients with different subtypes of CLE, such as acute CLE (ACLE, 304 patients), subacute CLE (SCLE, 236 patients), chronic CLE (CCLE, 397 patients), and intermittent CLE (ICLE, 65 patients), from 13 European countries were collected and statistically analyzed by an SPSS database. The main outcome measures included gender, age at onset of disease, LE-specific and LE-nonspecific skin lesions, photosensitivity, laboratory features, and the criteria of the American College of Rheumatology (ACR) for the classification of systemic lupus erythematosus. The mean age at onset of disease was 43.0±15.7 years and differed significantly between the CLE subtypes. In 347 (34.6%) of the 1002 patients, two or more CLE subtypes were diagnosed during the course of the disease and 453 (45.2%) presented with LE-nonspecific manifestations. Drug-induced CLE and SjögrenD́s Syndrome had the highest prevalence in SCLE patients (13.1% and 14.0%, respectively). Photosensitivity was significantly more frequent in patients with ACLE, SCLE, and ICLE compared with those with CCLE. The detection of antinuclear antibodies such as anti-Ro/SSA and anti-La/SSB antibodies revealed further significant differences between the CLE subtypes. In summary, the EUSCLE Core Set Questionnaire and its database facilitate the analysis of clinical and laboratory features in a high number of patients with CLE and will contribute to standardized assessment and monitoring of the disease in Europe.
  •  
6.
  • Driemel, A., et al. (author)
  • From pole to pole: 33 years of physical oceanography onboard R/V Polarstern
  • 2017
  • In: Earth System Science Data. - : Copernicus GmbH. - 1866-3508 .- 1866-3516. ; 9:1, s. 211-220
  • Research review (peer-reviewed)abstract
    • Measuring temperature and salinity profiles in the world's oceans is crucial to understanding ocean dynamics and its influence on the heat budget, the water cycle, the marine environment and on our climate. Since 1983 the German research vessel and icebreaker Polarstern has been the platform of numerous CTD (conductivity, temperature, depth instrument) deployments in the Arctic and the Antarctic. We report on a unique data collection spanning 33 years of polar CTD data. In total 131 data sets (1 data set per cruise leg) containing data from 10 063 CTD casts are now freely available at doi: 10.1594/PANGAEA.860066. During this long period five CTD types with different characteristics and accuracies have been used. Therefore the instruments and processing procedures (sensor calibration, data validation, etc.) are described in detail. This compilation is special not only with regard to the quantity but also the quality of the data -the latter indicated for each data set using defined quality codes. The complete data collection includes a number of repeated sections for which the quality code can be used to investigate and evaluate long-term changes. Beginning with 2010, the salinity measurements presented here are of the highest quality possible in this field owing to the introduction of the OPTIMARE Precision Salinometer.
  •  
7.
  • Kaidar-Person, Orit, et al. (author)
  • The Lucerne Toolbox 2 to optimise axillary management for early breast cancer : a multidisciplinary expert consensus
  • 2023
  • In: EClinicalMedicine. - 2589-5370. ; 61
  • Research review (peer-reviewed)abstract
    • Clinical axillary lymph node management in early breast cancer has evolved from being merely an aspect of surgical management and now includes the entire multidisciplinary team. The second edition of the “Lucerne Toolbox”, a multidisciplinary consortium of European cancer societies and patient representatives, addresses the challenges of clinical axillary lymph node management, from diagnosis to local therapy of the axilla. Five working packages were developed, following the patients’ journey and addressing specific clinical scenarios. Panellists voted on 72 statements, reaching consensus (agreement of 75% or more) in 52.8%, majority (51%–74% agreement) in 43.1%, and no decision in 4.2%. Based on the votes, targeted imaging and standardized pathology of lymph nodes should be a prerequisite to planning local and systemic therapy, axillary lymph node dissection can be replaced by sentinel lymph node biopsy ( ± targeted approaches) in a majority of scenarios; and positive patient outcomes should be driven by both low recurrence risks and low rates of lymphoedema.
  •  
8.
  • Pantiora, Eirini, et al. (author)
  • Evolution and refinement of magnetically guided sentinel lymph node detection in breast cancer : meta-analysis
  • 2023
  • In: British Journal of Surgery. - : Oxford University Press. - 0007-1323 .- 1365-2168. ; 110:4, s. 410-419
  • Research review (peer-reviewed)abstract
    • BACKGROUND: Superparamagnetic iron oxide nanoparticles (SPIO) have been used as a tracer for sentinel lymph node (SLN) localization in breast cancer, demonstrating comparable performance to the combination of radioisotope (RI) and blue dye (BD).METHODS: A systematic literature search and meta-analysis with subgroup and meta-regression analysis were undertaken to update the available evidence, assess technique evolution, and define knowledge gaps. Recommendations were made using the GRADE approach.RESULTS: In 20 comparative studies, the detection rate was 97.5 per cent for SPIO and 96.5 per cent for RI ± BD (risk ratio 1.006, 95 per cent c.i. 0.992 to 1.019; P = 0.376, high-certainty evidence). Neoadjuvant therapy, injection site, injection volume or nodal metastasis burden did not affect the detection rate, but injection over 24 h before surgery increased the detection rate on meta-regression. Concordance was 99.0 per cent and reverse concordance 97.1 per cent (rate difference 0.003, 95 per cent c.i. -0.009 to 0.015; P = 0.656, high-certainty evidence). Use of SPIO led to retrieval of slightly more SLNs (pooled mean 1.96 versus 1.89) with a higher nodal detection rate (94.1 versus 83.5 per cent; RR 1.098, 1.058 to 1.140; P < 0.001; low-certainty evidence). In meta-regression, injection over 24 h before surgery increased the SPIO nodal yield over that of RI ± BD. The skin-staining rate was 30.8 per cent (very low-certainty evidence), and possibly prevented with use of smaller doses and peritumoral injection.CONCLUSION: The performance of SPIO is comparable to that of RI ± BD. Preoperative injection increases the detection rate and nodal yield, without affecting concordance. Whether skin staining and MRI artefacts are reduced by lower dose and peritumoral injection needs to be investigated.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-8 of 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view