SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Koskinen Seppo) ;lar1:(liu)"

Search: WFRF:(Koskinen Seppo) > Linköping University

  • Result 1-3 of 3
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Björkman, Ann-Sofi, et al. (author)
  • Sensitivity of DECT in ACL tears. A prospective study with arthroscopy as reference method
  • 2022
  • In: Acta Radiologica Open. - : Sage Publications. - 2058-4601. ; 11:3
  • Journal article (peer-reviewed)abstract
    • Background: CT is often used for fracture evaluation following knee trauma and to diagnose ACL injuries would also be valuable. Purpose: To investigate the diagnostic accuracy of dual energy CT (DECT) for detection of ACL tears in acute and subacute knee injuries. Material and Methods: Patients with suspected ACL injury were imaged with DECT and MRI. Clinically blinded DECT images were independently read twice by two radiologists. ACL was classified as normal or abnormal. Arthroscopy served as reference method. Sensitivity and positive predictive value (PPV) were calculated, and diagnostic performance between DECT and MRI was assessed. Results: 48 patients (26 M, 22 F, mean age 23 years, range 15-37 years) were imaged with a mean of 25 days following trauma. Of these, 21 patients underwent arthroscopy with a mean of 195 days after trauma. Arthroscopy revealed 19 ACL tears and 2 ACLs with no tear. The combined sensitivity was 76.3% (95% CI 66.8-85.9) and 86.8 (95% CI 71.9-95.6) for DECT and MRI, respectively. There was no statistically significant difference between these two methods (p = .223). The positive predictive value (PPV) was 93.5 (95% CI 84.3-98.2) and 91.7 (95% CI 77.5-98.3) for DECT and MRI, respectively. Conclusion: DECT has lower sensitivity to detect an ACL rupture than MRI, but the difference is not statistically significant. The PPV is high in both methods.
  •  
2.
  • Björkman, Ann-Sofi, et al. (author)
  • Spectral photon-counting CT: Image quality evaluation using a metal-containing bovine bone specimen
  • 2023
  • In: European Journal of Radiology. - : ELSEVIER IRELAND LTD. - 0720-048X .- 1872-7727. ; 168
  • Journal article (peer-reviewed)abstract
    • Purpose: To find the optimal imaging parameters for a photon-counting detector CT (PCD-CT) and to compare it to an energy-integrating detector CT (EID-CT) in terms of image quality and metal artefact severity using a metal-containing bovine knee specimen. Methods: A bovine knee with a stainless-steel plate and screws was imaged in a whole-body research PCD-CT at 120 kV and 140 kV and in an EID dual-source CT (DSCT) at Sn150 kV and 80/Sn150 kV. PCD-CT virtual monoenergetic 72 and 150 keV images and EID-CT images processed with and without metal artefact reduction algorithms (iMAR) were compared. Four radiologists rated the visualisation of bony structures and metal artefact severity. The Friedman test and Wilcoxon signed-rank test with Bonferronis correction were used. P-values of <= 0.0001 were considered statistically significant. Distributions of HU values of regions of interest (ROIs) in artefact-affected areas were analysed.Results: PCD-CT 140 kV 150 keV images received the highest scores and were significantly better than EID-CT Sn150 kV images. PCD-CT 72 keV images were rated significantly lower than all the others. HU-value variation was larger in the 120 kV and the 72 keV images. The ROI analysis revealed no large difference between scanners regarding artefact severity.Conclusion: PCD-CT 140 kV 150 keV images of a metal-containing bovine knee specimen provided the best image quality. They were superior to, or as good as, the best EID-CT images; even without the presumed advantage of tin filter and metal artefact reduction algorithms. PCD-CT is a promising method for reducing metal artefacts.
  •  
3.
  • Nummela, Mari T., et al. (author)
  • Costal cartilage fractures in blunt polytrauma patients - a prospective clinical and radiological follow-up study
  • 2022
  • In: Emergency Radiology. - : SPRINGER HEIDELBERG. - 1070-3004 .- 1438-1435. ; 29:5, s. 845-854
  • Journal article (peer-reviewed)abstract
    • Purpose To assess the healing of costal cartilage fractures (CCFX) in patients with blunt polytrauma with follow-up imaging and clinical examination. Effect on physical performance and quality of life (QoL) was also evaluated. Methods The study group comprised twenty-one patients with diagnosed CCFX in trauma CT. All the patients underwent MRI, ultrasound, ultra-low-dose CT examinations, and clinical status control. The patients completed QoL questionnaires. Two radiologists evaluated the images regarding fracture union, dislocation, calcifications, and persistent edema at fracture site. An attending trauma surgeon clinically examined the patients, with emphasis on focal tenderness and ribcage mobility. Trauma registry data were accessed to evaluate injury severity and outcome. Results The patients were imaged at an average of 34.1 months (median 36, range 15.8-57.7) after the initial trauma. In 15 patients (71.4%), CCFX were considered stable on imaging. Cartilage calcifications were seen on healed fracture sites in all the patients. The fracture dislocation had increased in 5 patients (23.8%), and 1 patient (4.8%) showed signs of a non-stable union. Four patients (19.0%) reported persistent symptoms from CCFX. Conclusion Non-union in CCFX is uncommon but may lead to decreased stability and discomfort. Both clinical and radiological examinations play an important part in the post-traumatic evaluation of CCFX. CT and MRI visualize the healing process, while dynamic ultrasound may reveal instability. No significant difference in QoL was detected between patients with radiologically healed and non-healed CCFX. Post-traumatic disability was mostly due to other non-thoracic injuries.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-3 of 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view