SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lammertsma Adriaan A.) ;pers:(de Haan Stefan)"

Sökning: WFRF:(Lammertsma Adriaan A.) > De Haan Stefan

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Danad, Ibrahim, et al. (författare)
  • Carotid artery intima-media thickness, but not coronary artery calcium, predicts coronary vascular resistance in patients evaluated for coronary artery disease
  • 2012
  • Ingår i: European Heart Journal: Cardiovascular Imaging. - : Oxford University Press (OUP). - 2047-2404 .- 2047-2412. ; 13:4, s. 317-323
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims There is growing evidence that coronary artery disease (CAD) affects not only the conduit epicardial coronary arteries, but also the microvascular coronary bed. Moreover, coronary microvascular dysfunction (CMVD) often precedes the stage of clinically overt epicardial CAD. Coronary artery calcium (CAC) and carotid intima-media thickness (C-IMT) measured with computed tomography (CT) and ultrasound, respectively, are among the available techniques to non-invasively assess atherosclerotic burden. An increased CAC score and C-IMT have also been associated with CMVD. It is therefore of interest to explore and compare the potential of CAC against C-IMT to predict minimal coronary vascular resistance (CVR). Methods and results We evaluated 120 patients (mean age 56 +/- 9 years, 58 men) without a documented history of CAD in whom and results obstructive CAD was excluded. All patients underwent C-IMT measurements, CAC scoring, and vasodilator stress O-15-water positron emission tomography (PET)/CT, during which the coronary flow reserve (CFR) and minimal CVR were analysed. Minimal CVR increased significantly with increasing tertiles of C-IMT (22 +/- 6, 27 +/- 11, and 28 +/- 9 mmHg mL(-1) min(-1) g(-1), P < 0.01), whereas the CFR was comparable across all C-IMT groups (P = 0.50). Minimal CVR increased significantly with an increase in CAC score (23 +/- 9, 27 +/- 8, 32 +/- 10, and 32 +/- 7 mmHg mL(-1) min(-1) g(-1). P < 0.01), whereas the CFR did not show a significant decrease with higher CAC scores (P = 0.18). Multivariable regression analysis revealed that C-IMT (P = 0.03), but not CAC, was independently associated with minimal CVR. Conclusion C-IMT, but not CAC score, independently predicts minimal CVR in patients with multiple cardiovascular risk factors and suspected of CAD.
  •  
2.
  • Danad, Ibrahim, et al. (författare)
  • Coronary risk factors and myocardial blood flow in patients evaluated for coronary artery disease : a quantitative [15O]H2O PET/CT study
  • 2012
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 39:1, s. 102-112
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundThere has been increasing interest in quantitative myocardial blood flow (MBF) imaging over the last years and it is expected to become a routinely used technique in clinical practice. Positron emission tomography (PET) using [15O]H2O is the established gold standard for quantification of MBF in vivo. A fundamental issue when performing quantitative MBF imaging is to define the limits of MBF in a clinically suitable population. The aims of the present study were to determine the limits of MBF and to determine the relationship among coronary artery disease (CAD) risk factors, gender and MBF in a predominantly symptomatic patient cohort without significant CAD.MethodsA total of 128 patients (mean age 54 ± 10 years, 50 men) with a low to intermediate pretest likelihood of CAD were referred for noninvasive evaluation of CAD using a hybrid PET/computed tomography (PET/CT) scanner. MBF was quantified with [15O]H2O at rest and during adenosine-induced hyperaemia. Obstructive CAD was excluded in these patients by means of invasive or CT-based coronary angiography.ResultsGlobal average baseline MBF values were 0.91 ± 0.34 and 1.09 ± 0.30  ml·min−1·g−1 (range 0.54–2.35  and 0.59–2.75 ml·min−1·g−1) in men and women, respectively (p < 0.01). However, no gender-dependent difference in baseline MBF was seen following correction for rate–pressure product (0.98 ± 0.45 and 1.09 ± 0.30 ml·min−1·g−1 in men and women, respectively; p = 0.08). Global average hyperaemic MBF values were 3.44 ± 1.20 ml·min−1·g−1 in the whole study population, and 2.90 ± 0.85 and 3.78 ± 1.27 ml·min−1·g−1 (range 1.52–5.22 and 1.72–8.15 ml·min−1·g−1) in men and women, respectively (p < 0.001). Multivariate analysis identified male gender, age and body mass index as having an independently negative impact on hyperaemic MBF.ConclusionGender, age and body mass index substantially influence reference values and should be corrected for when interpreting hyperaemic MBF values.
  •  
3.
  • de Haan, Stefan, et al. (författare)
  • Parametric imaging of myocardial viability using ¹⁵O-labelled water and PET/CT : comparison with late gadolinium-enhanced CMR
  • 2012
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 39:8, s. 1240-1245
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeThe perfusable tissue index (PTI) is a marker of myocardial viability. Recent technological advances have made it possible to generate parametric PTI images from a single [15O]H2O PET/CT scan. The purpose of this study was to validate these parametric PTI images.MethodsThe study population comprised 46 patients with documented or suspected coronary artery disease who were studied with [15O]H2O PET and late gadolinium-enhanced (LGE) cardiac magnetic resonance imaging (CMR).ResultsOf the 736 myocardial segments included, 364 showed some degree of LGE. PTI and perfusable tissue fraction (PTF) diminished with increasing LGE. The areas under the curve of the PTI and PTF, used to predict (near) transmural LGE on CMR, were 0.86 and 0.87, respectively. Optimal sensitivity and specificity were 91 % and 73 % for PTI and 69 % and 87 % for PTF, respectively.ConclusionPTI and PTF assessed with a single [15O]H2O scan can be utilized as markers of myocardial viability in patients with coronary artery disease.
  •  
4.
  • Harms, Hendrik J., et al. (författare)
  • Noninvasive Quantification of Myocardial C-11-Meta-Hydroxyephedrine Kinetics
  • 2016
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 57:9, s. 1376-1381
  • Tidskriftsartikel (refereegranskat)abstract
    • C-11-meta-hydroxyephedrine (C-11-HED) kinetics in the myocardium can be quantified using a single-tissue-compartment model together with a metabolite-corrected arterial blood sampler input function (BSIF). The need for arterial blood sampling, however, limits clinical applicability. The purpose of this study was to investigate the feasibility of replacing arterial sampling with imaging-derived input function (IDIF) and venous blood samples. Methods: Twenty patients underwent 60-min dynamic C-11-HED PET/CT scans with online arterial blood sampling. Thirteen of these patients also underwent venous blood sampling. Data were reconstructed using both 3 dimensional row-action maximum-likelihood algorithm (3DR) and a time-of-flight (TF) list-mode reconstruction algorithm. For each reconstruction, IDIF results were compared with BSIF results. In addition, IDIF results obtained with venous blood samples and with a transformed venous-to-arterial metabolite correction were compared with results obtained with arterial metabolite corrections. Results: Correlations between IDIF- and BSIF-derived K-1 and V-T were high (r(2) > =0.89 for 3DR and TF). Slopes of the linear fits were significantly different from 1 for K-1, for both 3DR (slope = 0.94) and TF (slope = 1.06). For V-T, the slope of the linear fit was different from 1 for TF (slope = 0.93) but not for 3DR (slope = 0.98). Use of venous blood data introduced a large bias in V-T (r(2) = 0.96, slope = 0.84) and a small bias in K-1 (r(2) = 0.99, slope = 0.98). Use of a second-order polynomial venous-to-arterial transformation was robust and greatly reduced bias in V-T (r(2) = 0.97, slope = 0.99) with no effect on K-1. Conclusion: IDIF yielded precise results for both 3DR and TF. Venous blood samples can be used for absolute quantification of C-11-HED studies, provided a venous-to-arterial transformation is applied. A venous-to-arterial transformation enables noninvasive, absolute quantification of C-11-HED studies.
  •  
5.
  • Harms, Hendrik J, et al. (författare)
  • Parametric Images of Myocardial Viability Using a Single 15O-H2O PET/CT Scan
  • 2011
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 52:5, s. 745-749
  • Tidskriftsartikel (refereegranskat)abstract
    • Perfusable tissue index (PTI) is a marker of myocardial viability and requires acquisition of transmission, 15O-CO, and 15O-H2O scans. The aim of this study was to generate parametric PTI images from a 15O-H2O PET/CT scan without an additional 15O-CO scan.Methods:Data from 20 patients undergoing both 15O-H2O and 15O-CO scans were used, assessing correlation between PTI based on 15O-CO (PTICO) and on fitted blood volume fractions (PTIVb). In addition, parametric PTIVb images of 10 patients undergoing 15O-H2O PET/CT scans were generated using basis-function methods and compared with PTIVb obtained using nonlinear regression. Simulations were performed to study the effects of noise on PTIVb.Results:Correlation between PTICO and PTIVb was high (r2 = 0.73). Parametric PTIVb correlated well with PTIVb obtained using nonlinear regression (r2 = 0.91). Simulations showed low sensitivity to noise (coefficient of variation < 10% at 20% noise).Conclusion:Parametric PTI images can be generated from a single 15O-H2O PET/CT scan.
  •  
6.
  • Harms, Hendrik J, et al. (författare)
  • Quantification of [(11)C]-meta-hydroxyephedrine uptake in human myocardium
  • 2014
  • Ingår i: EJNMMI Research. - : Springer Science and Business Media LLC. - 2191-219X. ; 4
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The aims of this study were to determine the optimal tracer kinetic model for [(11)C]-meta-hydroxyephedrine ([(11)C]HED) and to evaluate the performance of several simplified methods.METHODS: Thirty patients underwent dynamic 60-min [(11)C]HED scans with online arterial blood sampling. Single-tissue and both reversible and irreversible two-tissue models were fitted to the data using the metabolite-corrected arterial input function. For each model, reliable fits were defined as those yielding outcome parameters with a coefficient of variation (CoV) <25%. The optimal model was determined using Akaike and Schwarz criteria and the F-test, together with the number of reliable fits. Simulations were performed to study accuracy and precision of each model. Finally, quantitative results obtained using a population-averaged metabolite correction were evaluated, and simplified retention index (RI) and standardized uptake value (SUV) results were compared with quantitative volume of distribution (V T) data.RESULTS: The reversible two-tissue model was preferred in 75.8% of all segments, based on the Akaike information criterion. However, V T derived using the single-tissue model correlated highly with that of the two-tissue model (r (2) = 0.94, intraclass correlation coefficient (ICC) = 0.96) and showed higher precision (CoV of 24.6% and 89.2% for single- and two-tissue models, respectively, at 20% noise). In addition, the single-tissue model yielded reliable fits in 94.6% of all segments as compared with 77.1% for the reversible two-tissue model. A population-averaged metabolite correction could not be used in approximately 20% of the patients because of large biases in V T. RI and SUV can provide misleading results because of non-linear relationships with V T.CONCLUSIONS: Although the reversible two-tissue model provided the best fits, the single-tissue model was more robust and results obtained were similar. Therefore, the single-tissue model was preferred. RI showed a non-linear correlation with V T, and therefore, care has to be taken when using RI as a quantitative measure.
  •  
7.
  • Harms, Hendrik J, et al. (författare)
  • Use of a Single 11C-Meta-Hydroxyephedrine Scan for Assessing Flow-Innervation Mismatches in Patients with Ischemic Cardiomyopathy
  • 2015
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 56:11, s. 1706-1711
  • Tidskriftsartikel (refereegranskat)abstract
    • UNLABELLED: Mismatch between areas of reduced myocardial blood flow (MBF) and reduced myocardial innervation (defect areas) may be used to estimate the risk for ventricular arrhythmias. The presence of a mismatch zone can be derived using a combined protocol consisting of both an MBF scan and an (11)C-meta-hydroxyephedrine ((11)C-HED) scan. The rate of influx from blood to myocardium (K1) of (11)C-HED is proportional to MBF and can potentially be used as an index for defining MBF defects. The aim of this study was to assess whether K1 derived from an (11)C-HED scan can be used as an index of MBF, potentially allowing for an assessment of MBF-innervation mismatch areas from a single (11)C-HED scan.METHODS: Seventeen patients with known ischemic cardiomyopathy underwent dynamic (15)O-water and (11)C-HED scans. Discrete arterial blood samples were taken during (11)C-HED scans for metabolite correction of the image-derived input function. (11)C-HED influx rate was obtained using a single-tissue-compartment model and compared with transmural MBF (MBFT), defined as MBF as measured with (15)O-water multiplied by perfusable tissue fraction. Defect sizes were obtained from parametric K1 and MBFT images, using 50% of a remote control segment as the cutoff value.RESULTS: There was a significant correlation between MBFT and K1 (y = 0.40x + 0.05 mL·g(-1)·min(-1), r = 0.80, P < 0.001), although K1 was significantly lower than MBFT (slope of the regression line significantly different from 1, P < 0.001). Correlation between MBFT and K1 defect sizes was high (y = 0.89x + 1.38%, r = 0.95, P < 0.001), with no significant difference in mean defect size based on K1 or MBFT (20.9% ± 11.3% and 20.1% ± 10.7% for MBFT and K1, respectively, P = 0.41).CONCLUSION: (11)C-HED influx rate K1 can be used as an alternative to a separate MBF scan for assessing mismatch areas between MBF and myocardial innervation.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy