1. |
- Carlsson, Ella, et al.
(author)
-
Mass composition of the escaping plasma at Mars
- 2006
-
In: Icarus. - : Elsevier BV. - 0019-1035 .- 1090-2643. ; 182:2, s. 320-328
-
Journal article (peer-reviewed)abstract
- Data from the Ion Mass Analyzer (IMA) sensor of the ASPERA-3 instrument suite on Mars Express have been analyzed to determine the mass composition of the escaping ion species at Mars. We have examined 77 different ion-beam events and we present the results in terms of flux ratios between the following ion species: CO2+/O+ and O-2(+)/O+. The following ratios averaged over all events and energies were identified: CO2+/O+ = 0.2 and O-2(+)/O+ = 0.9. The values measured are significantly higher, by a factor of 10 for O-2(+)/O+, than a contemporary modeled ratio for the maximum fluxes which the martian ionosphere can supply. The most abundant ion species was found to be O+, followed by O-2(+) and CO2+. We estimate the loss of CO2+ to be 4.0 x 10(24) s(-1) (0.29 kg s(-1)) by using the previous measurements of Phobos-2 in our calculations. The dependence of the ion ratios in relation to their energy ranges we studied, 0.3-3.0 keV, indicated that no clear correlation was found.
|
|
2. |
|
|
3. |
|
|
4. |
|
|
5. |
|
|
6. |
- Lewis, G. R., et al.
(author)
-
The calibration of the Cassini-Huygens CAPS Electron Spectrometer
- 2010
-
In: Planetary and Space Science. - : Elsevier BV. - 0032-0633 .- 1873-5088. ; 58:3, s. 427-436
-
Journal article (peer-reviewed)abstract
- We present the two-stage method used to calibrate the electron spectrometer (ELS), part of the plasma spectrometer (CAPS) on board the Cassini spacecraft currently in orbit around Saturn. The CAPS-ELS is a top-hat electrostatic analyser designed to measure electron fluxes between 0 5 eV and 26 keV The on-ground calibration method described here includes the production of photoelectrons, which are energised and passed into the CAPS-ELS in a purpose designed calibration facility. Knowledge of the intensity of these incident electrons and the subsequent instrument output provides an on-ground calibrated geometric factor. Comparative studies of physical quantities such as plasma density and electron differential flux calculated using on-ground calibration factor with the quantities deduced from the wave experiment and high energy electron detector provide in-flight calibration. The results of this are presented together with a comparison of the experimentally calibrated values with simulated calibration values.
|
|
7. |
|
|
8. |
|
|
9. |
|
|
10. |
|
|