SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Ljungberg Börje 1949 ) ;mspu:(article);hsvcat:2"

Search: WFRF:(Ljungberg Börje 1949 ) > Journal article > Engineering and Technology

  • Result 1-2 of 2
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Candefjord, Stefan, et al. (author)
  • Combining scanning haptic microscopy and fibre optic Raman spectroscopy for tissue characterization
  • 2012
  • In: Journal of Medical Engineering & Technology. - : Taylor & Francis. - 0309-1902 .- 1464-522X. ; 36:6, s. 319-327
  • Journal article (peer-reviewed)abstract
    • The tactile resonance method (TRM) and Raman spectroscopy (RS) are promising for tissue characterization in vivo. Our goal is to combine these techniques into one instrument, to use TRM for swift scanning, and RS for increasing the diagnostic power. The aim of this study was to determine the classification accuracy, using support vector machines, for measurements on porcine tissue and also produce preliminary data on human prostate tissue. This was done by developing a new experimental set-up combining micro-scale TRMscanning haptic microscopy (SHM)for assessing stiffness on a micro-scale, with fibre optic RS measurements for assessing biochemical content. We compared the accuracy using SHM alone versus SHM combined with RS, for different degrees of tissue homogeneity. The cross-validation classification accuracy for healthy porcine tissue types using SHM alone was 6581%, and when RS was added it increased to 8187%. The accuracy for healthy and cancerous human tissue was 6770% when only SHM was used, and increased to 7277% for the combined measurements. This shows that the potential for swift and accurate classification of healthy and cancerous prostate tissue is high. This is promising for developing a tool for probing the surgical margins during prostate cancer surgery. 
  •  
2.
  • Lindahl, Olof A, et al. (author)
  • A tactile resonance sensor for prostate cancer detection – evaluation on human prostate tissue
  • 2021
  • In: Biomedical Engineering & Physics Express. - : Institute of Physics (IOP). - 2057-1976. ; 7:2
  • Journal article (peer-reviewed)abstract
    • Prostate cancer surgery risks erectile problems and incontinence for the patient. An instrument for guiding surgeons to avoid nerve bundle damage and ensure complete cancer removal is desirable. We present a tactile resonance sensor made of PZT ceramics, mounted in a 3D motorized translation stage for scanning and measuring tissue stiffness for detecting cancer in human prostate. The sensor may be used during surgery for guidance, scanning the prostate surface for the presence of cancer, indicating migration of cancer cells into surrounding tissue. Ten fresh prostates, obtained from patients undergoing prostate cancer surgery, were cut into 0.5 cm thick slices. Each slice was measured for tissue stiffness at about 25 different sites and compared to histology for validation cancer prediction by stiffness. The statistical analysis was based on a total of 148 sites with non-cancer and 40 sites with cancer. Using a generalized linear mixed model (GLMM), the stiffness data predicted cancer with an area under the curve of 0.74, after correcting for overfitting using bootstrap validation. Mean prostate stiffness on the logarithmic scale (p = 0.015) and standardized Z-scores (p = 0.025) were both significant predictors of cancer. This study concludes that stiffness measured by the tactile resonance sensor is a significant predictor of prostate cancer with potential for future development towards a clinical instrument for surgical guidance.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-2 of 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view