SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lubberink M) ;pers:(Lammertsma Adriaan A)"

Sökning: WFRF:(Lubberink M) > Lammertsma Adriaan A

  • Resultat 1-10 av 18
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • van Assema, Danielle M. E., et al. (författare)
  • Blood-brain barrier P-glycoprotein function in Alzheimer's disease
  • 2012
  • Ingår i: Brain. - : Oxford University Press (OUP). - 0006-8950 .- 1460-2156. ; 135, s. 181-189
  • Tidskriftsartikel (refereegranskat)abstract
    • A major pathological hallmark of Alzheimer's disease is accumulation of amyloid-beta in senile plaques in the brain. Evidence is accumulating that decreased clearance of amyloid-beta from the brain may lead to these elevated amyloid-beta levels. One of the clearance pathways of amyloid-beta is transport across the blood-brain barrier via efflux transporters. P-glycoprotein, an efflux pump highly expressed at the endothelial cells of the blood-brain barrier, has been shown to transport amyloid-beta. P-glycoprotein function can be assessed in vivo using (R)-[C-11]verapamil and positron emission tomography. The aim of this study was to assess blood-brain barrier P-glycoprotein function in patients with Alzheimer's disease compared with age-matched healthy controls using (R)-[C-11]verapamil and positron emission tomography. In 13 patients with Alzheimer's disease (age 65 +/- 7 years, Mini-Mental State Examination 23 +/- 3), global (R)-[C-11]verapamil binding potential values were increased significantly (P = 0.001) compared with 14 healthy controls (aged 62 +/- 4 years, Mini-Mental State Examination 30 +/- 1). Global (R)-[C-11]verapamil binding potential values were 2.18 +/- 0.25 for patients with Alzheimer's disease and 1.77 +/- 0.41 for healthy controls. In patients with Alzheimer's disease, higher (R)-[C-11]verapamil binding potential values were found for frontal, parietal, temporal and occipital cortices, and posterior and anterior cingulate. No significant differences between groups were found for medial temporal lobe and cerebellum. These data show altered kinetics of (R)-[C-11]verapamil in Alzheimer's disease, similar to alterations seen in studies where P-glycoprotein is blocked by a pharmacological agent. As such, these data indicate that P-glycoprotein function is decreased in patients with Alzheimer's disease. This is the first direct evidence that the P-glycoprotein transporter at the blood-brain barrier is compromised in sporadic Alzheimer's disease and suggests that decreased P-glycoprotein function may be involved in the pathogenesis of Alzheimer's disease.
  •  
2.
  • van Assema, Danielle M. E., et al. (författare)
  • No evidence for additional blood-brain barrier P-glycoprotein dysfunction in Alzheimer's disease patients with microbleeds
  • 2012
  • Ingår i: Journal of Cerebral Blood Flow and Metabolism. - : SAGE Publications. - 0271-678X .- 1559-7016. ; 32:8, s. 1468-1471
  • Tidskriftsartikel (refereegranskat)abstract
    • Decreased blood-brain barrier P-glycoprotein (Pgp) function has been shown in Alzheimer's disease (AD) patients using positron emission tomography (PET) with the radiotracer (R)-[C-11] verapamil. Decreased Pgp function has also been hypothesized to promote cerebral amyloid angiopathy (CAA) development. Here, we used PET and (R)-[C-11] verapamil to assess Pgp function in eighteen AD patients, of which six had microbleeds (MBs), presumably reflecting underlying CAA. No differences were found in binding potential and nonspecific volume of distribution of (R)-[C-11] verapamil between patient groups. These results provide no evidence for additional Pgp dysfunction in AD patients with MBs.
  •  
3.
  • van der Veldt, Astrid A. M., et al. (författare)
  • Rapid Decrease in Delivery of Chemotherapy to Tumors after Anti-VEGF Therapy : Implications for Scheduling of Anti-Angiogenic Drugs
  • 2012
  • Ingår i: Cancer Cell. - : Elsevier BV. - 1535-6108 .- 1878-3686. ; 21:1, s. 82-91
  • Tidskriftsartikel (refereegranskat)abstract
    • Current strategies combining anti-angiogenic drugs with chemotherapy provide clinical benefit in cancer patients. It is assumed that anti-angiogenic drugs, such as bevacizumab, transiently normalize abnormal tumor vasculature and contribute to improved delivery of subsequent chemotherapy. To investigate this concept, a study was performed in non-small cell lung cancer (NSCLC) patients using positron emission tomography (PET) and radiolabeled docetaxel ([11C]docetaxel). In NSCLC, bevacizumab reduced both perfusion and net influx rate of [11C]docetaxel within 5 hr. These effects persisted after 4 days. The clinical relevance of these findings is notable, as there was no evidence for a substantial improvement in drug delivery to tumors. These findings highlight the importance of drug scheduling and advocate further studies to optimize scheduling of anti-angiogenic drugs.
  •  
4.
  • Bahce, Idris, et al. (författare)
  • Development of [11C]erlotinib Positron Emission Tomography for In Vivo Evaluation of EGF Receptor Mutational Status
  • 2013
  • Ingår i: Clinical Cancer Research. - 1078-0432 .- 1557-3265. ; 19:1, s. 183-193
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To evaluate whether, in patients with non-small cell lung carcinoma (NSCLC), tumor uptake of [(11)C]erlotinib can be quantified and imaged using positron emission tomography and to assess whether the level of tracer uptake corresponds with the presence of activating tumor EGF receptor (EGFR) mutations.EXPERIMENTAL DESIGN: Ten patients with NSCLCs, five with an EGFR exon 19 deletion, and five without were scanned twice (test retest) on the same day with an interval of at least 4 hours. Each scanning procedure included a low-dose computed tomographic scan, a 10-minute dynamic [(15)O]H(2)O scan, and a 1-hour dynamic [(11)C]erlotinib scan. Data were analyzed using full tracer kinetic modeling. EGFR expression was evaluated using immunohistochemistry.RESULTS: The quantitative measure of [(11)C]erlotinib uptake, that is, volume of distribution (V(T)), was significantly higher in tumors with activating mutations, that is, all with exon 19 deletions (median V(T), 1.76; range, 1.25-2.93), than in those without activating mutations (median V(T), 1.06; range, 0.67-1.22) for both test and retest data (P = 0.014 and P = 0.009, respectively). Good reproducibility of [(11)C]erlotinib V(T) was seen (intraclass correlation coefficient = 0.88). Intergroup differences in [(11)C]erlotinib uptake were not correlated with EGFR expression levels, nor tumor blood flow.CONCLUSION: [(11)C]erlotinib V(T) was significantly higher in NSCLCs tumors with EGFR exon 19 deletions.
  •  
5.
  • van Assema, Danielle M. E., et al. (författare)
  • P-Glycoprotein Function at the Blood-Brain Barrier : Effects of Age and Gender
  • 2012
  • Ingår i: Molecular Imaging and Biology. - : Springer Science and Business Media LLC. - 1536-1632 .- 1860-2002. ; 14:6, s. 771-776
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeP-glycoprotein (Pgp) is an efflux transporter involved in transport of several compounds across the blood–brain barrier (BBB). Loss of Pgp function with increasing age may be involved in the development of age-related disorders, but this may differ between males and females. Pgp function can be quantified in vivo using (R)-[11C]verapamil and positron emission tomography. The purpose of this study was to assess global and regional effects of both age and gender on BBB Pgp function.ProceduresThirty-five healthy men and women in three different age groups were included. Sixty minutes dynamic (R)-[11C]verapamil scans with metabolite-corrected arterial plasma input curves were acquired. Grey matter time–activity curves were fitted to a validated constrained two-tissue compartment plasma input model, providing the volume of distribution (V T) of (R)-[11C]verapamil as outcome measure.ResultsIncreased V T of (R)-[11C]verapamil with aging was found in several large brain regions in men. Young and elderly women showed comparable V T values. Young women had higher V T compared with young men.ConclusionsDecreased BBB Pgp is found with aging; however, effects of age on BBB Pgp function differ between men and women.
  •  
6.
  • van der Veldt, Astrid A M, et al. (författare)
  • Absolute Quantification of [11C]docetaxel Kinetics in Lung Cancer Patients Using Positron Emission Tomography
  • 2011
  • Ingår i: Clinical Cancer Research. - 1078-0432 .- 1557-3265. ; 17:14, s. 4814-4824
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose:Tumor resistance to docetaxel may be associated with reduced drug concentrations in tumor tissue. Positron emission tomography (PET) allows for quantification of radiolabeled docetaxel ([11C]docetaxel) kinetics and might be useful for predicting response to therapy. The primary objective was to evaluate the feasibility of quantitative [11C]docetaxel PET scans in lung cancer patients. The secondary objective was to investigate whether [11C]docetaxel kinetics were associated with tumor perfusion, tumor size, and dexamethasone administration.Experimental Design:Thirty-four lung cancer patients underwent dynamic PET–computed tomography (CT) scans using [11C]docetaxel. Blood flow was measured using oxygen-15 labeled water. The first 24 patients were premedicated with dexamethasone. For quantification of [11C]docetaxel kinetics, the optimal tracer kinetic model was developed and a noninvasive procedure was validated.Results:Reproducible quantification of [11C]docetaxel kinetics in tumors was possible using a noninvasive approach (image derived input function). Thirty-two lesions (size ≥4 cm3) were identified, having a variable net influx rate of [11C]docetaxel (range, 0.0023–0.0229 mL·cm−3·min−1). [11C]docetaxel uptake was highly related to tumor perfusion (Spearman's ρ = 0.815;P < 0.001), but not to tumor size (Spearman's ρ = −0.140; P = 0.446). Patients pretreated with dexamethasone showed lower [11C]docetaxel uptake in tumors (P = 0.013). Finally, in a subgroup of patients who subsequently received docetaxel therapy, relative high [11C]docetaxel uptake was related with improved tumor response.Conclusions:Quantification of [11C]docetaxel kinetics in lung cancer was feasible in a clinical setting. Variable [11C]docetaxel kinetics in tumors may reflect differential sensitivity to docetaxel therapy. Our findings warrant further studies investigating the predictive value of [11C]docetaxel uptake and the effects of comedication on [11C]docetaxel kinetics in tumors.
  •  
7.
  • van der Veldt, Astrid A. M., et al. (författare)
  • Toward Prediction of Efficacy of Chemotherapy : A Proof of Concept Study in Lung Cancer Patients Using [11C]docetaxel and Positron Emission Tomography
  • 2013
  • Ingår i: Clinical Cancer Research. - 1078-0432 .- 1557-3265. ; 19:15, s. 4163-4173
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose:Pharmacokinetics of docetaxel can be measured in vivo using positron emission tomography (PET) and a microdose of radiolabeled docetaxel ([11C]docetaxel). The objective of this study was to investigate whether a [11C]docetaxel PET microdosing study could predict tumor uptake of therapeutic doses of docetaxel.Experimental Design:Docetaxel-naïve lung cancer patients underwent 2 [11C]docetaxel PET scans; one after bolus injection of [11C]docetaxel and another during combined infusion of [11C]docetaxel and a therapeutic dose of docetaxel (75 mg·m−2). Compartmental and spectral analyses were used to quantify [11C]docetaxel tumor kinetics. [11C]docetaxel PET measurements were used to estimate the area under the curve (AUC) of docetaxel in tumors. Tumor response was evaluated using computed tomography scans.Results:Net rates of influx (Ki) of [11C]docetaxel in tumors were comparable during microdosing and therapeutic scans. [11C]docetaxel AUCTumor during the therapeutic scan could be predicted reliably using an impulse response function derived from the microdosing scan together with the plasma curve of [11C]docetaxel during the therapeutic scan. At 90 minutes, the accumulated amount of docetaxel in tumors was less than 1% of the total infused dose of docetaxel. [11C]docetaxel Ki derived from the microdosing scan correlated with AUCTumor of docetaxel (Spearman ρ = 0.715; P = 0.004) during the therapeutic scan and with tumor response to docetaxel therapy (Spearman ρ = −0.800; P = 0.010).Conclusions:Microdosing data of [11C]docetaxel PET can be used to predict tumor uptake of docetaxel during chemotherapy. The present study provides a framework for investigating the PET microdosing concept for radiolabeled anticancer drugs in patients.
  •  
8.
  • Danad, Ibrahim, et al. (författare)
  • Carotid artery intima-media thickness, but not coronary artery calcium, predicts coronary vascular resistance in patients evaluated for coronary artery disease
  • 2012
  • Ingår i: European Heart Journal: Cardiovascular Imaging. - : Oxford University Press (OUP). - 2047-2404 .- 2047-2412. ; 13:4, s. 317-323
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims There is growing evidence that coronary artery disease (CAD) affects not only the conduit epicardial coronary arteries, but also the microvascular coronary bed. Moreover, coronary microvascular dysfunction (CMVD) often precedes the stage of clinically overt epicardial CAD. Coronary artery calcium (CAC) and carotid intima-media thickness (C-IMT) measured with computed tomography (CT) and ultrasound, respectively, are among the available techniques to non-invasively assess atherosclerotic burden. An increased CAC score and C-IMT have also been associated with CMVD. It is therefore of interest to explore and compare the potential of CAC against C-IMT to predict minimal coronary vascular resistance (CVR). Methods and results We evaluated 120 patients (mean age 56 +/- 9 years, 58 men) without a documented history of CAD in whom and results obstructive CAD was excluded. All patients underwent C-IMT measurements, CAC scoring, and vasodilator stress O-15-water positron emission tomography (PET)/CT, during which the coronary flow reserve (CFR) and minimal CVR were analysed. Minimal CVR increased significantly with increasing tertiles of C-IMT (22 +/- 6, 27 +/- 11, and 28 +/- 9 mmHg mL(-1) min(-1) g(-1), P < 0.01), whereas the CFR was comparable across all C-IMT groups (P = 0.50). Minimal CVR increased significantly with an increase in CAC score (23 +/- 9, 27 +/- 8, 32 +/- 10, and 32 +/- 7 mmHg mL(-1) min(-1) g(-1). P < 0.01), whereas the CFR did not show a significant decrease with higher CAC scores (P = 0.18). Multivariable regression analysis revealed that C-IMT (P = 0.03), but not CAC, was independently associated with minimal CVR. Conclusion C-IMT, but not CAC score, independently predicts minimal CVR in patients with multiple cardiovascular risk factors and suspected of CAD.
  •  
9.
  • Golla, Sandeep S. V., et al. (författare)
  • Partial volume correction of brain PET studies using iterative deconvolution in combination with HYPR denoising
  • 2017
  • Ingår i: EJNMMI Research. - : Springer Science and Business Media LLC. - 2191-219X. ; 7:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Accurate quantification of PET studies depends on the spatial resolution of the PET data. The commonly limited PET resolution results in partial volume effects (PVE). Iterative deconvolution methods (IDM) have been proposed as a means to correct for PVE. IDM improves spatial resolution of PET studies without the need for structural information (e.g. MR scans). On the other hand, deconvolution also increases noise, which results in lower signal-to-noise ratios (SNR). The aim of this study was to implement IDM in combination with HighlY constrained back-PRojection (HYPR) denoising to mitigate poor SNR properties of conventional IDM.METHODS: An anthropomorphic Hoffman brain phantom was filled with an [18F]FDG solution of ~25 kBq mL-1 and scanned for 30 min on a Philips Ingenuity TF PET/CT scanner (Philips, Cleveland, USA) using a dynamic brain protocol with various frame durations ranging from 10 to 300 s. Van Cittert IDM was used for PVC of the scans. In addition, HYPR was used to improve SNR of the dynamic PET images, applying it both before and/or after IDM. The Hoffman phantom dataset was used to optimise IDM parameters (number of iterations, type of algorithm, with/without HYPR) and the order of HYPR implementation based on the best average agreement of measured and actual activity concentrations in the regions. Next, dynamic [11C]flumazenil (five healthy subjects) and [11C]PIB (four healthy subjects and four patients with Alzheimer's disease) scans were used to assess the impact of IDM with and without HYPR on plasma input-derived distribution volumes (VT) across various regions of the brain.RESULTS: In the case of [11C]flumazenil scans, Hypr-IDM-Hypr showed an increase of 5 to 20% in the regional VT whereas a 0 to 10% increase or decrease was seen in the case of [11C]PIB depending on the volume of interest or type of subject (healthy or patient). References for these comparisons were the VTs from the PVE-uncorrected scans.CONCLUSIONS: IDM improved quantitative accuracy of measured activity concentrations. Moreover, the use of IDM in combination with HYPR (Hypr-IDM-Hypr) was able to correct for PVE without increasing noise.
  •  
10.
  • Knudsen, Gitte M, et al. (författare)
  • Guidelines for the content and format of PET brain data in publications and archives : A consensus paper
  • 2020
  • Ingår i: Journal of Cerebral Blood Flow and Metabolism. - : SAGE Publications. - 0271-678X .- 1559-7016. ; 40:8, s. 1576-1585
  • Tidskriftsartikel (refereegranskat)abstract
    • It is a growing concern that outcomes of neuroimaging studies often cannot be replicated. To counteract this, the magnetic resonance (MR) neuroimaging community has promoted acquisition standards and created data sharing platforms, based on a consensus on how to organize and share MR neuroimaging data. Here, we take a similar approach to positron emission tomography (PET) data. To facilitate comparison of findings across studies, we first recommend publication standards for tracer characteristics, image acquisition, image preprocessing, and outcome estimation for PET neuroimaging data. The co-authors of this paper, representing more than 25 PET centers worldwide, voted to classify information as mandatory, recommended, or optional. Second, we describe a framework to facilitate data archiving and data sharing within and across centers. Because of the high cost of PET neuroimaging studies, sample sizes tend to be small and relatively few sites worldwide have the required multidisciplinary expertise to properly conduct and analyze PET studies. Data sharing will make it easier to combine datasets from different centers to achieve larger sample sizes and stronger statistical power to test hypotheses. The combining of datasets from different centers may be enhanced by adoption of a common set of best practices in data acquisition and analysis.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 18

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy