SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lubberink Mark) ;pers:(Kero Tanja)"

Sökning: WFRF:(Lubberink Mark) > Kero Tanja

  • Resultat 1-10 av 25
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Antoni, Gunnar, et al. (författare)
  • In Vivo Visualization of Amyloid Deposits in the Heart with C-11-PIB and PET
  • 2013
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 54:2, s. 213-220
  • Tidskriftsartikel (refereegranskat)abstract
    • Cardiac amyloidosis is a differential diagnosis in heart failure and is associated with high mortality. There is currently no noninvasive imaging test available for specific diagnosis. N-[methyl-C-11]2-(4'-methylamino-phenyl)-6-hydroxybenzothiazole (C-11-PIB) PET is used in the evaluation of brain amyloidosis. We evaluated the potential use of C-11-PIB PET in systemic amyloidosis affecting the heart. Methods: Patients (n = 10) diagnosed with systemic amyloidosis-including heart involvement of either monoclonal immunoglobulin light-chain (AL) or transthyretin (ATTR) type- and healthy volunteers (n = 5) were investigated with PET/CT using C-11-PIB to study cardiac amyloid deposits and with C-11-acetate to measure myocardial blood flow to study the impact of global and regional perfusion on PIB retention. Results: Myocardial C-11-PIB uptake was visually evident in all patients 15-25 min after injection and was not seen in any volunteer. A significant difference in C-11-PIB retention in the heart between patients and healthy controls was found. The data indicate that myocardial amyloid deposits in patients diagnosed with systemic amyloidosis could be visualized with C-11-PIB. No correlation between C-11-PIB retention index and myocardial blood flow as measured with C-11-acetate was found on the global level, whereas a positive correlation on the segmental level was seen in a single patient. Conclusion: C-11-PIB and PET could be a method to study systemic amyloidosis of type AL and ATTR affecting the heart and should be investigated further both as a diagnostic tool and as a noninvasive method for treatment follow-up.
  •  
2.
  • Bouyoucef, S E, et al. (författare)
  • Poster Session 2 : Monday 4 May 2015, 08
  • 2015
  • Ingår i: European Heart Journal Cardiovascular Imaging. - : Oxford University Press (OUP). - 2047-2404 .- 2047-2412. ; 16 Suppl 1
  • Tidskriftsartikel (refereegranskat)
  •  
3.
  • Christensen, Nana L, et al. (författare)
  • Detection and correction of patient motion in dynamic 15O-water PET MPI.
  • 2023
  • Ingår i: Journal of Nuclear Cardiology. - : Elsevier. - 1071-3581 .- 1532-6551. ; 30:6, s. 2736-2749
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Patient motion constitutes a limitation to 15O-water cardiac PET imaging. We examined the ability of image readers to detect and correct patient motion using simulated motion data and clinical patient scans.METHODS: Simulated data consisting of 16 motions applied to 10 motion-free scans were motion corrected using two approaches, pre-analysis and post-analysis for motion identification. Both approaches employed a manual frame-by-frame correction method. In addition, a clinical cohort was analyzed for assessment of prevalence and effect of motion and motion correction.RESULTS: Motion correction was performed on 94% (pre-analysis) and 64% (post-analysis) of the scans. Large motion artifacts were corrected in 91% (pre-analysis) and 74% (post-analysis) of scans. Artifacts in MBF were reduced in 56% (pre-analysis) and 58% (post-analysis) of the scans. The prevalence of motion in the clinical patient cohort (n = 762) was 10%. Motion correction altered exam interpretation in only 10 (1.3%) clinical patient exams.CONCLUSION: Frame-by-frame motion correction after visual inspection is useful in reducing motion artifacts in cardiac 15O-water PET. Reviewing the initial results (parametric images and polar maps) as part of the motion correction process, reduced erroneous corrections in motion-free scans. In a large clinical cohort, the impact of motion correction was limited to few patients.
  •  
4.
  •  
5.
  • Kero, Tanja, et al. (författare)
  • Accurate analysis and visualization of cardiac (11)C-PIB uptake in amyloidosis with semiautomatic software
  • 2016
  • Ingår i: Journal of Nuclear Cardiology. - : Springer Science and Business Media LLC. - 1071-3581 .- 1532-6551. ; 23:4, s. 741-750
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: (11)C-PIB PET is a promising non-invasive diagnostic tool for cardiac amyloidosis. Semiautomatic analysis of PET data is now available but it is not known how accurate these methods are for amyloid imaging. The aim of this study was to evaluate the feasibility of one semiautomatic software tool for analysis and visualization of (11)C-PIB left ventricular retention index (RI) in cardiac amyloidosis.METHODS AND RESULTS: Patients with systemic amyloidosis and cardiac involvement (n = 10) and healthy controls (n = 5) were investigated with dynamic (11)C-PIB PET. Two observers analyzed the PET studies with semiautomatic software to calculate the left ventricular RI of (11)C-PIB and to create parametric images. The mean RI at 15-25 min from the semiautomatic analysis was compared with RI based on manual analysis and showed comparable values (0.056 vs 0.054 min(-1) for amyloidosis patients and 0.024 vs 0.025 min(-1) in healthy controls; P = .78) and the correlation was excellent (r = 0.98). Inter-reader reproducibility also was excellent (intraclass correlation coefficient, ICC > 0.98). Parametric polarmaps and histograms made visual separation of amyloidosis patients and healthy controls fast and simple.CONCLUSION: Accurate semiautomatic analysis of cardiac (11)C-PIB RI in amyloidosis patients is feasible. Parametric polarmaps and histograms make visual interpretation fast and simple.
  •  
6.
  • Kero, Tanja, et al. (författare)
  • Evaluation of quantitative CMR perfusion imaging by comparison with simultaneous 15O-water-PET
  • 2021
  • Ingår i: Journal of Nuclear Cardiology. - : Springer Science and Business Media LLC. - 1071-3581 .- 1532-6551. ; 28, s. 1252-1266
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundWe assessed the quantitative accuracy of cardiac perfusion measurements using dynamic contrast-enhanced MRI with simultaneous 15O-water PET as reference with a fully integrated PET-MR scanner.Methods15 patients underwent simultaneous DCE MRI and 15O-water PET scans at rest and adenosine-stress on an integrated PET-MR scanner. Correlation and agreement between MRI- and PET-based global and regional MBF values were assessed using correlation and Bland–Altman analysis.ResultsThree subjects were excluded due to technical problems. Global mean (± SD) MBF values at rest and stress were 0.97 ± 0.27 and 3.19 ± 0.70 mL/g/min for MRI and 1.02 ± 0.28 and 3.13 ± 1.16 mL/g/min for PET (P = 0.66 and P = 0.81). The correlations between global and regional MRI- and PET-based MBF values were strong (r = 0.86 and r = 0.75). The biases were negligible for both global and regional MBF comparisons (0.01 and 0.00 mL/min/g for both), but the limits of agreement were wide for both global and regional MBF, with larger variability for high MBF-values.ConclusionThe correlation between simultaneous MBF measurements with DCE MRI and 15O-water PET measured in an integrated PET-MRI was strong but the agreement was only moderate indicating that MRI-based quantitative MBF measurements is not ready for clinical introduction.
  •  
7.
  • Kero, Tanja (författare)
  • Methodological aspects of quantitative cardiac molecular imaging
  • 2018
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The objective of this research was to facilitate the use of quantitative cardiac molecular imaging by developing and validating methods and applications. More specifically:we determined the optimal tracer kinetic model for analysis of 11C-PIB and evaluated the performance of two simpler measures, retention index (RI) and standardized uptake value (SUV), in the quantification of cardiac 11C-PIB uptake in amyloidosis. An irreversible two-tissue (2Tirr) model best described the 11C-PIB uptake in cardiac amyloidosis. RI and SUV showed high correlation with quantitative results from this kinetic model and also a better discrimination between amyloidosis patients and controls than a 2Tirr model with population averaged metabolite correction. RI and SUV are furthermore more feasible for use in clinical routine and therefore the preferred measure to use in PET diagnosis of cardiac amyloidosis. We also tested the feasibility of a semiautomatic software to analyze RI and visualize cardiac uptake of 11C-PIB in amyloidosis. The RI values were comparable with RI based on manual segmentation, showing significantly higher 11C-PIB RI in amyloidosis patients than in healthy volunteers. A fast and accurate semiautomatic analysis process is thus feasible to use for PET in cardiac amyloidosis instead of the laborious manual analyses that were used so far.Furthermore, we assessed the quantitative accuracy of cardiac perfusion measurements with 15O-water PET in a digital time-of-flight PET-MR scanner. A high correlation and agreement between PET-MR based and PET-CT based MBF was found; cardiac perfusion measurements with 15O-water can therefore be performed accurately with the fully integrated Signa PET-MR scanner. Finally, we assessed the quantitative accuracy of cardiac perfusion measurements using dynamic contrast-enhanced MRI with simultaneous 15O-water PET as reference at rest and during adenosine-induced hyperemia with a fully integrated PET-MR scanner. The correlations between global and regional MRI- and PET-based MBF values were good and the biases were negliable for both global and regional MBF comparisons, but the limits of agreement were wide for both global and regional MBF, with larger variability for high MBF-values indicating that MRI-based quantitative MBF measurement based on widely available acquisition protocols is not yet ready for clinical introduction.
  •  
8.
  • Kero, Tanja, et al. (författare)
  • Quantification of (11)C-PIB kinetics in cardiac amyloidosis
  • 2020
  • Ingår i: Journal of Nuclear Cardiology. - : Springer Science and Business Media LLC. - 1071-3581 .- 1532-6551. ; 27:3, s. 774-784
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The purpose of this work was to determine the optimal tracer kinetic model of (11)C-PIB and to validate the use of the simplified methods retention index (RI) and standardized uptake value (SUV) for quantification of cardiac (11)C-PIB uptake in amyloidosis. METHODS AND RESULTS: Single-tissue, reversible and irreversible two-tissue models were fitted to data from seven cardiac amyloidosis patients who underwent (11)C-PIB PET scans and arterial blood sampling for measurement of blood radioactivity and metabolites. The irreversible two-tissue model (2Tirr) best described cardiac (11)C-PIB uptake. RI and SUV showed high correlation with the rate of irreversible binding (Ki) from the 2Tirr model (r(2 )=0.95 and r(2 )=0.94). Retrospective data from 10 amyloidosis patients and 5 healthy controls were analyzed using RI, SUV, as well as compartment modelling with a population-average metabolite correction. All measures were higher in amyloidosis patients than in healthy controls (p=.001), but with an overlap between groups for Ki. CONCLUSION: An irreversible two-tissue model best describes the (11)C-PIB uptake in cardiac amyloidosis. RI and SUV correlate well with Ki from the 2Tirr model. RI and SUV discriminate better between amyloidosis patients and controls than Ki based on population-average metabolite correction.
  •  
9.
  •  
10.
  • Kero, Tanja, et al. (författare)
  • Quantitative myocardial blood flow imaging with integrated time-of-flight PET-MR
  • 2017
  • Ingår i: EJNMMI Physics. - : Springer Science and Business Media LLC. - 2197-7364. ; 4:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The use of integrated PET-MR offers new opportunities for comprehensive assessment of cardiac morphology and function. However, little is known on the quantitative accuracy of cardiac PET imaging with integrated time-of-flight PET-MR. The aim of the present work was to validate the GE Signa PET-MR scanner for quantitative cardiac PET perfusion imaging. Eleven patients (nine male; mean age 59 years; range 46-74 years) with known or suspected coronary artery disease underwent (15)O-water PET scans at rest and during adenosine-induced hyperaemia on a GE Discovery ST PET-CT and a GE Signa PET-MR scanner. PET-MR images were reconstructed using settings recommended by the manufacturer, including time-of-flight (TOF). Data were analysed semi-automatically using Cardiac VUer software, resulting in both parametric myocardial blood flow (MBF) images and segment-based MBF values. Correlation and agreement between PET-CT-based and PET-MR-based MBF values for all three coronary artery territories were assessed using regression analysis and intra-class correlation coefficients (ICC). In addition to the cardiac PET-MR reconstruction protocol as recommended by the manufacturer, comparisons were made using a PET-CT resolution-matched reconstruction protocol both without and with TOF to assess the effect of time-of-flight and reconstruction parameters on quantitative MBF values.RESULTS: Stress MBF data from one patient was excluded due to movement during the PET-CT scanning. Mean MBF values at rest and stress were (0.92 ± 0.12) and (2.74 ± 1.37) mL/g/min for PET-CT and (0.90 ± 0.23) and (2.65 ± 1.15) mL/g/min for PET-MR (p = 0.33 and p = 0.74). ICC between PET-CT-based and PET-MR-based regional MBF was 0.98. Image quality was improved with PET-MR as compared to PET-CT. ICC between PET-MR-based regional MBF with and without TOF and using different filter and reconstruction settings was 1.00.CONCLUSIONS: PET-MR-based MBF values correlated well with PET-CT-based MBF values and the parametric PET-MR images were excellent. TOF and reconstruction settings had little impact on MBF values.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 25

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy