SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lubberink Mark) ;pers:(Schuit Robert C)"

Sökning: WFRF:(Lubberink Mark) > Schuit Robert C

  • Resultat 1-10 av 10
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bahce, Idris, et al. (författare)
  • Development of [11C]erlotinib Positron Emission Tomography for In Vivo Evaluation of EGF Receptor Mutational Status
  • 2013
  • Ingår i: Clinical Cancer Research. - 1078-0432 .- 1557-3265. ; 19:1, s. 183-193
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To evaluate whether, in patients with non-small cell lung carcinoma (NSCLC), tumor uptake of [(11)C]erlotinib can be quantified and imaged using positron emission tomography and to assess whether the level of tracer uptake corresponds with the presence of activating tumor EGF receptor (EGFR) mutations.EXPERIMENTAL DESIGN: Ten patients with NSCLCs, five with an EGFR exon 19 deletion, and five without were scanned twice (test retest) on the same day with an interval of at least 4 hours. Each scanning procedure included a low-dose computed tomographic scan, a 10-minute dynamic [(15)O]H(2)O scan, and a 1-hour dynamic [(11)C]erlotinib scan. Data were analyzed using full tracer kinetic modeling. EGFR expression was evaluated using immunohistochemistry.RESULTS: The quantitative measure of [(11)C]erlotinib uptake, that is, volume of distribution (V(T)), was significantly higher in tumors with activating mutations, that is, all with exon 19 deletions (median V(T), 1.76; range, 1.25-2.93), than in those without activating mutations (median V(T), 1.06; range, 0.67-1.22) for both test and retest data (P = 0.014 and P = 0.009, respectively). Good reproducibility of [(11)C]erlotinib V(T) was seen (intraclass correlation coefficient = 0.88). Intergroup differences in [(11)C]erlotinib uptake were not correlated with EGFR expression levels, nor tumor blood flow.CONCLUSION: [(11)C]erlotinib V(T) was significantly higher in NSCLCs tumors with EGFR exon 19 deletions.
  •  
2.
  • Harms, Hendrik J., et al. (författare)
  • Noninvasive Quantification of Myocardial C-11-Meta-Hydroxyephedrine Kinetics
  • 2016
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 57:9, s. 1376-1381
  • Tidskriftsartikel (refereegranskat)abstract
    • C-11-meta-hydroxyephedrine (C-11-HED) kinetics in the myocardium can be quantified using a single-tissue-compartment model together with a metabolite-corrected arterial blood sampler input function (BSIF). The need for arterial blood sampling, however, limits clinical applicability. The purpose of this study was to investigate the feasibility of replacing arterial sampling with imaging-derived input function (IDIF) and venous blood samples. Methods: Twenty patients underwent 60-min dynamic C-11-HED PET/CT scans with online arterial blood sampling. Thirteen of these patients also underwent venous blood sampling. Data were reconstructed using both 3 dimensional row-action maximum-likelihood algorithm (3DR) and a time-of-flight (TF) list-mode reconstruction algorithm. For each reconstruction, IDIF results were compared with BSIF results. In addition, IDIF results obtained with venous blood samples and with a transformed venous-to-arterial metabolite correction were compared with results obtained with arterial metabolite corrections. Results: Correlations between IDIF- and BSIF-derived K-1 and V-T were high (r(2) > =0.89 for 3DR and TF). Slopes of the linear fits were significantly different from 1 for K-1, for both 3DR (slope = 0.94) and TF (slope = 1.06). For V-T, the slope of the linear fit was different from 1 for TF (slope = 0.93) but not for 3DR (slope = 0.98). Use of venous blood data introduced a large bias in V-T (r(2) = 0.96, slope = 0.84) and a small bias in K-1 (r(2) = 0.99, slope = 0.98). Use of a second-order polynomial venous-to-arterial transformation was robust and greatly reduced bias in V-T (r(2) = 0.97, slope = 0.99) with no effect on K-1. Conclusion: IDIF yielded precise results for both 3DR and TF. Venous blood samples can be used for absolute quantification of C-11-HED studies, provided a venous-to-arterial transformation is applied. A venous-to-arterial transformation enables noninvasive, absolute quantification of C-11-HED studies.
  •  
3.
  • Harms, Hendrik J, et al. (författare)
  • Quantification of [(11)C]-meta-hydroxyephedrine uptake in human myocardium
  • 2014
  • Ingår i: EJNMMI Research. - : Springer Science and Business Media LLC. - 2191-219X. ; 4
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The aims of this study were to determine the optimal tracer kinetic model for [(11)C]-meta-hydroxyephedrine ([(11)C]HED) and to evaluate the performance of several simplified methods.METHODS: Thirty patients underwent dynamic 60-min [(11)C]HED scans with online arterial blood sampling. Single-tissue and both reversible and irreversible two-tissue models were fitted to the data using the metabolite-corrected arterial input function. For each model, reliable fits were defined as those yielding outcome parameters with a coefficient of variation (CoV) <25%. The optimal model was determined using Akaike and Schwarz criteria and the F-test, together with the number of reliable fits. Simulations were performed to study accuracy and precision of each model. Finally, quantitative results obtained using a population-averaged metabolite correction were evaluated, and simplified retention index (RI) and standardized uptake value (SUV) results were compared with quantitative volume of distribution (V T) data.RESULTS: The reversible two-tissue model was preferred in 75.8% of all segments, based on the Akaike information criterion. However, V T derived using the single-tissue model correlated highly with that of the two-tissue model (r (2) = 0.94, intraclass correlation coefficient (ICC) = 0.96) and showed higher precision (CoV of 24.6% and 89.2% for single- and two-tissue models, respectively, at 20% noise). In addition, the single-tissue model yielded reliable fits in 94.6% of all segments as compared with 77.1% for the reversible two-tissue model. A population-averaged metabolite correction could not be used in approximately 20% of the patients because of large biases in V T. RI and SUV can provide misleading results because of non-linear relationships with V T.CONCLUSIONS: Although the reversible two-tissue model provided the best fits, the single-tissue model was more robust and results obtained were similar. Therefore, the single-tissue model was preferred. RI showed a non-linear correlation with V T, and therefore, care has to be taken when using RI as a quantitative measure.
  •  
4.
  • Harms, Hendrik J, et al. (författare)
  • Use of a Single 11C-Meta-Hydroxyephedrine Scan for Assessing Flow-Innervation Mismatches in Patients with Ischemic Cardiomyopathy
  • 2015
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 56:11, s. 1706-1711
  • Tidskriftsartikel (refereegranskat)abstract
    • UNLABELLED: Mismatch between areas of reduced myocardial blood flow (MBF) and reduced myocardial innervation (defect areas) may be used to estimate the risk for ventricular arrhythmias. The presence of a mismatch zone can be derived using a combined protocol consisting of both an MBF scan and an (11)C-meta-hydroxyephedrine ((11)C-HED) scan. The rate of influx from blood to myocardium (K1) of (11)C-HED is proportional to MBF and can potentially be used as an index for defining MBF defects. The aim of this study was to assess whether K1 derived from an (11)C-HED scan can be used as an index of MBF, potentially allowing for an assessment of MBF-innervation mismatch areas from a single (11)C-HED scan.METHODS: Seventeen patients with known ischemic cardiomyopathy underwent dynamic (15)O-water and (11)C-HED scans. Discrete arterial blood samples were taken during (11)C-HED scans for metabolite correction of the image-derived input function. (11)C-HED influx rate was obtained using a single-tissue-compartment model and compared with transmural MBF (MBFT), defined as MBF as measured with (15)O-water multiplied by perfusable tissue fraction. Defect sizes were obtained from parametric K1 and MBFT images, using 50% of a remote control segment as the cutoff value.RESULTS: There was a significant correlation between MBFT and K1 (y = 0.40x + 0.05 mL·g(-1)·min(-1), r = 0.80, P < 0.001), although K1 was significantly lower than MBFT (slope of the regression line significantly different from 1, P < 0.001). Correlation between MBFT and K1 defect sizes was high (y = 0.89x + 1.38%, r = 0.95, P < 0.001), with no significant difference in mean defect size based on K1 or MBFT (20.9% ± 11.3% and 20.1% ± 10.7% for MBFT and K1, respectively, P = 0.41).CONCLUSION: (11)C-HED influx rate K1 can be used as an alternative to a separate MBF scan for assessing mismatch areas between MBF and myocardial innervation.
  •  
5.
  • Lubberink, Mark, et al. (författare)
  • Myocardial Oxygen Extraction Fraction Measured Using Bolus Inhalation of O-15-Oxygen Gas and Dynamic PET
  • 2011
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 52:1, s. 60-66
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to determine the accuracy of oxygen extraction fraction (OEF) measurements using a dynamic scan protocol after bolus inhalation of O-15(2). The method of analysis was optimized by investigating potential reuse of myocardial blood flow (MBF), perfusable tissue fraction, and blood and lung spillover factors derived from separate O-15-water and (CO)-O-15 scans. Methods: Simulations were performed to assess the accuracy and precision of OEF for a variety of models in which different parameters from O-15-water and (CO)-O-15 scans were reused. Reproducibility was assessed in 8 patients who underwent one 10-min dynamic scan after bolus injection of 1.1 GBq of O-15-water, two 10-min dynamic scans after bolus inhalation of 1.4 GBq of O-15(2), and a 6-min static scan after bolus inhalation of 0.8 GBq of (CO)-O-15 for region-of-interest definition. Results: Simulations showed that accuracy and precision were lowest when all parameters were determined from the O-15(2) scan. The optimal accuracy and precision of OEF were obtained when fixing MBF, perfusable tissue fraction, and blood spillover to values derived from a O-15-water scan and estimating spillover from the pulmonary gas volume using an attenuation map. Optimal accuracy and precision were confirmed in the patient study, showing an OEF test-retest variability of 13% for the whole myocardium. Correction of spillover from pulmonary gas volume requires correction of the lung time-activity curve for pulmonary blood volume, which could equally well be obtained from a O-15-water rather than (CO)-O-15 scan. Conclusion: Measurement of OEF is possible using bolus inhalation of O-15(2) and a dynamic scan protocol, with optimal accuracy and precision when other relevant parameters, such as MBF, are derived from an additional O-15-water scan.
  •  
6.
  • van Assema, Daniëlle ME, et al. (författare)
  • Blood-brain barrier P-glycoprotein function in healthy subjects and Alzheimer's disease patients : effect of polymorphisms in the ABCB1 gene
  • 2012
  • Ingår i: EJNMMI Research. - 2191-219X. ; 2
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: P-glycoprotein is a blood-brain barrier efflux transporter involved in the clearance of amyloid-beta from the brain and, as such, might be involved in the pathogenesis of Alzheimer's disease. P-glycoprotein is encoded by the highly polymorphic ABCB1 gene. Single-nucleotide polymorphisms in the ABCB1 gene have been associated with altered P-glycoprotein expression and function. P-glycoprotein function at the blood-brain barrier can be quantified in vivo using the P-glycoprotein substrate tracer (R)-[11C]verapamil and positron emission tomography (PET). The purpose of this study was to assess the effects of C1236T, G2677T/A and C3435T single-nucleotide polymorphisms in ABCB1 on blood-brain barrier P-glycoprotein function in healthy subjects and patients with Alzheimer's disease.METHODS: Thirty-two healthy subjects and seventeen patients with Alzheimer's disease underwent 60-min dynamic (R)-[11C]verapamil PET scans. The binding potential of (R)-[11C]verapamil was assessed using a previously validated constrained two-tissue plasma input compartment model and used as outcome measure. DNA was isolated from frozen blood samples and C1236T, G2677T/A and C3435T single-nucleotide polymorphisms were amplified by polymerase chain reaction.RESULTS: In healthy controls, binding potential did not differ between subjects without and with one or more T present in C1236T, G2677T and C3435T. In contrast, patients with Alzheimer's disease with one or more T in C1236T, G2677T and C3435T had significantly higher binding potential values than patients without a T. In addition, there was a relationship between binding potential and T dose in C1236T and G2677T.CONCLUSIONS: In Alzheimer's disease patients, C1236T, G2677T/A and C3435T single-nucleotide polymorphisms may be related to changes in P-glycoprotein function at the blood-brain barrier. As such, genetic variations in ABCB1 might contribute to the progression of amyloid-beta deposition in the brain.
  •  
7.
  • van Assema, Danielle M. E., et al. (författare)
  • Blood-brain barrier P-glycoprotein function in Alzheimer's disease
  • 2012
  • Ingår i: Brain. - : Oxford University Press (OUP). - 0006-8950 .- 1460-2156. ; 135, s. 181-189
  • Tidskriftsartikel (refereegranskat)abstract
    • A major pathological hallmark of Alzheimer's disease is accumulation of amyloid-beta in senile plaques in the brain. Evidence is accumulating that decreased clearance of amyloid-beta from the brain may lead to these elevated amyloid-beta levels. One of the clearance pathways of amyloid-beta is transport across the blood-brain barrier via efflux transporters. P-glycoprotein, an efflux pump highly expressed at the endothelial cells of the blood-brain barrier, has been shown to transport amyloid-beta. P-glycoprotein function can be assessed in vivo using (R)-[C-11]verapamil and positron emission tomography. The aim of this study was to assess blood-brain barrier P-glycoprotein function in patients with Alzheimer's disease compared with age-matched healthy controls using (R)-[C-11]verapamil and positron emission tomography. In 13 patients with Alzheimer's disease (age 65 +/- 7 years, Mini-Mental State Examination 23 +/- 3), global (R)-[C-11]verapamil binding potential values were increased significantly (P = 0.001) compared with 14 healthy controls (aged 62 +/- 4 years, Mini-Mental State Examination 30 +/- 1). Global (R)-[C-11]verapamil binding potential values were 2.18 +/- 0.25 for patients with Alzheimer's disease and 1.77 +/- 0.41 for healthy controls. In patients with Alzheimer's disease, higher (R)-[C-11]verapamil binding potential values were found for frontal, parietal, temporal and occipital cortices, and posterior and anterior cingulate. No significant differences between groups were found for medial temporal lobe and cerebellum. These data show altered kinetics of (R)-[C-11]verapamil in Alzheimer's disease, similar to alterations seen in studies where P-glycoprotein is blocked by a pharmacological agent. As such, these data indicate that P-glycoprotein function is decreased in patients with Alzheimer's disease. This is the first direct evidence that the P-glycoprotein transporter at the blood-brain barrier is compromised in sporadic Alzheimer's disease and suggests that decreased P-glycoprotein function may be involved in the pathogenesis of Alzheimer's disease.
  •  
8.
  • van Assema, Danielle M. E., et al. (författare)
  • P-Glycoprotein Function at the Blood-Brain Barrier : Effects of Age and Gender
  • 2012
  • Ingår i: Molecular Imaging and Biology. - : Springer Science and Business Media LLC. - 1536-1632 .- 1860-2002. ; 14:6, s. 771-776
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeP-glycoprotein (Pgp) is an efflux transporter involved in transport of several compounds across the blood–brain barrier (BBB). Loss of Pgp function with increasing age may be involved in the development of age-related disorders, but this may differ between males and females. Pgp function can be quantified in vivo using (R)-[11C]verapamil and positron emission tomography. The purpose of this study was to assess global and regional effects of both age and gender on BBB Pgp function.ProceduresThirty-five healthy men and women in three different age groups were included. Sixty minutes dynamic (R)-[11C]verapamil scans with metabolite-corrected arterial plasma input curves were acquired. Grey matter time–activity curves were fitted to a validated constrained two-tissue compartment plasma input model, providing the volume of distribution (V T) of (R)-[11C]verapamil as outcome measure.ResultsIncreased V T of (R)-[11C]verapamil with aging was found in several large brain regions in men. Young and elderly women showed comparable V T values. Young women had higher V T compared with young men.ConclusionsDecreased BBB Pgp is found with aging; however, effects of age on BBB Pgp function differ between men and women.
  •  
9.
  • van Assema, Daniëlle Me, et al. (författare)
  • Reproducibility of quantitative (R)-[11C]verapamil studies
  • 2012
  • Ingår i: EJNMMI Research. - 2191-219X. ; 2
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundP-glycoprotein [Pgp] dysfunction may be involved in neurodegenerative diseases, such as Alzheimer's disease, and in drug resistant epilepsy. Positron emission tomography using the Pgp substrate tracer (R)-[11C]verapamil enables in vivo quantification of Pgp function at the human blood-brain barrier. Knowledge of test-retest variability is important for assessing changes over time or after treatment with disease-modifying drugs. The purpose of this study was to assess reproducibility of several tracer kinetic models used for analysis of (R)-[11C]verapamil data.MethodsDynamic (R)-[11C]verapamil scans with arterial sampling were performed twice on the same day in 13 healthy controls. Data were reconstructed using both filtered back projection [FBP] and partial volume corrected ordered subset expectation maximization [PVC OSEM]. All data were analysed using single-tissue and two-tissue compartment models. Global and regional test-retest variability was determined for various outcome measures.ResultsAnalysis using the Akaike information criterion showed that a constrained two-tissue compartment model provided the best fits to the data. Global test-retest variability of the volume of distribution was comparable for single-tissue (6%) and constrained two-tissue (9%) compartment models. Using a single-tissue compartment model covering the first 10 min of data yielded acceptable global test-retest variability (9%) for the outcome measure K1. Test-retest variability of binding potential derived from the constrained two-tissue compartment model was less robust, but still acceptable (22%). Test-retest variability was comparable for PVC OSEM and FBP reconstructed data.ConclusionThe model of choice for analysing (R)-[11C]verapamil data is a constrained two-tissue compartment model.
  •  
10.
  • van der Veldt, Astrid A M, et al. (författare)
  • Absolute Quantification of [11C]docetaxel Kinetics in Lung Cancer Patients Using Positron Emission Tomography
  • 2011
  • Ingår i: Clinical Cancer Research. - 1078-0432 .- 1557-3265. ; 17:14, s. 4814-4824
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose:Tumor resistance to docetaxel may be associated with reduced drug concentrations in tumor tissue. Positron emission tomography (PET) allows for quantification of radiolabeled docetaxel ([11C]docetaxel) kinetics and might be useful for predicting response to therapy. The primary objective was to evaluate the feasibility of quantitative [11C]docetaxel PET scans in lung cancer patients. The secondary objective was to investigate whether [11C]docetaxel kinetics were associated with tumor perfusion, tumor size, and dexamethasone administration.Experimental Design:Thirty-four lung cancer patients underwent dynamic PET–computed tomography (CT) scans using [11C]docetaxel. Blood flow was measured using oxygen-15 labeled water. The first 24 patients were premedicated with dexamethasone. For quantification of [11C]docetaxel kinetics, the optimal tracer kinetic model was developed and a noninvasive procedure was validated.Results:Reproducible quantification of [11C]docetaxel kinetics in tumors was possible using a noninvasive approach (image derived input function). Thirty-two lesions (size ≥4 cm3) were identified, having a variable net influx rate of [11C]docetaxel (range, 0.0023–0.0229 mL·cm−3·min−1). [11C]docetaxel uptake was highly related to tumor perfusion (Spearman's ρ = 0.815;P < 0.001), but not to tumor size (Spearman's ρ = −0.140; P = 0.446). Patients pretreated with dexamethasone showed lower [11C]docetaxel uptake in tumors (P = 0.013). Finally, in a subgroup of patients who subsequently received docetaxel therapy, relative high [11C]docetaxel uptake was related with improved tumor response.Conclusions:Quantification of [11C]docetaxel kinetics in lung cancer was feasible in a clinical setting. Variable [11C]docetaxel kinetics in tumors may reflect differential sensitivity to docetaxel therapy. Our findings warrant further studies investigating the predictive value of [11C]docetaxel uptake and the effects of comedication on [11C]docetaxel kinetics in tumors.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy