SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Mårtensson Thomas) ;pers:(Mårtensson Mikael 1989)"

Sökning: WFRF:(Mårtensson Thomas) > Mårtensson Mikael 1989

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Blanco, A., et al. (författare)
  • Performance of timing resistive plate chambers with relativistic neutrons from 300 to 1500 MeV
  • 2015
  • Ingår i: Journal of Instrumentation. - : IOP Publishing. - 1748-0221. ; 10:2
  • Tidskriftsartikel (refereegranskat)abstract
    • A prototype composed of four resistive plate chamber layers has been exposed to quasi-monoenergetic neutrons produced from a deuteron beam of varying energy (300 to 1500 AMeV) in experiment S406 at GSI, Darmstad, Germany. Each layer, with an active area of about 2000 × 500 mm2, is made of modules containing the active gaps, all in multigap construction. Each gap is defined by 0.3 mm nylon mono-filaments positioned between 2.85 mm thick float glass electrodes. The modules are operated in avalanche mode with a non-flammable gas mixture composed of 90% C2H2F4 and 10% SF6. The signals are readout by a pick-up electrode formed by 15 copper strips (per layer), spaced at a pitch of 30 mm, connected at both sides to timing front end electronics. Measurements of the time of flight jitter of neutrons, in the mentioned energy range, point to a contribution of the resistive plate chamber in the order of 150 ps, independent of the neutron energy.
  •  
2.
  • del Rio, J. S., et al. (författare)
  • CEPA: A LaBr 3 (Ce)/LaCl 3 (Ce) phoswich array for simultaneous detection of protons and gamma radiation emitted in reactions at relativistic energies
  • 2014
  • Ingår i: EPJ Web of Conferences. - : EDP Sciences. - 2101-6275 .- 2100-014X. ; 66
  • Konferensbidrag (refereegranskat)abstract
    • A prototype CEPA4, made of four optically isolated phoswich-crystals of LaBr3(Ce)+LaCl3(Ce) packed together in one can of Al, was tested with high energy protons (70-230 MeV) at the cyclotron of Krakow. Further, the response to different gamma radiation standard sources and cosmic muons was determined. Shape analysis of the pulses derived from the four individually coupled PM-tubes was performed and were used as input functions for Monte Carlo simulations in order to simulate the efficiencies and resolutions of a final detector design consisting of 750 such phoswich crystals arranged in a cylindrical disc. © Owned by the authors, published by EDP Sciences, 2014.
  •  
3.
  • del Rio, J. S., et al. (författare)
  • CEPA: A LaBr3(Ce)/LaCl3(Ce) Phoswich array for simultaneous detection of protons and gamma radiation emitted in reactions at relativistic energies
  • 2014
  • Ingår i: International Journal of Modern Physics: Conference Series. Applications of Nuclear Techniques (CRETE13). - 2010-1945. ; 27, s. 1460143-
  • Konferensbidrag (refereegranskat)abstract
    • A sophisticated design of 750 LaBr3(Ce):LaCl3(Ce) phoswich crystals (CEPA10) with a segmentation determined by the Doppler correction and an energy resolution of 5% at 1 MeV is presented. Monte Carlo simulations have been performed for high energy protons (50–500 MeV) and gamma radiation (0.5–30 MeV) to determine the length and shape of the crystals for optimum performance of the detector. In the case of protons, the two-layer detector can be used as a ΔELaBr3 − ETot telescope or, for very high energies, as a double energy loss detector (ΔELaBr3 + ΔELaCl3), in order to determine the initial energy. In addition, an experimental test with high energy protons (70–230 MeV) was performed at the cyclotron center in Krakow, Poland with a first prototype of 2 x 2 phoswich rectangular crystals (CEPA4) packed in an aluminum can (0.5 mm case). To simulate CEPA10 efficiencies and resolutions, optical pulses detected in CEPA4 by photomultiplier tubes with a DAQ system were used as energy input functions in Monte Carlo simulations.
  •  
4.
  • Machado, J., et al. (författare)
  • Performance of timing Resistive Plate Chambers with protons from 200 to 800 MeV
  • 2015
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 10:1, s. C01043-
  • Tidskriftsartikel (refereegranskat)abstract
    • A prototype composed of four resistive plate chamber layers has been exposed to quasi-monoenergetic protons produced from a deuteron beam of varying energy (200 to 800 AMeV) in experiment S406 at GSI, Darmstadt, Germany. The aim of the experiment is to characterize the response of the prototype to protons in this energy range, which deposit from 1.75 to 6 times more energy than minimum ionizing particles. Each layer, with an active area of about 2000 × 500 mm 2 , is made of modules containing the active gaps, all in multigap construction. Each gap is defined by 0.3 mm nylon mono-filaments positioned between 2.85 mm thick float glass electrodes. The modules are operated in avalanche mode with a non-flammable gas mixture composed of 90% C 2 H 2 F 4 and 10% SF 6 . The signals are readout by a pick-up electrode formed by 15 copper strips (per layer), spaced at a pitch of 30 mm, connected at both sides to timing front end electronics. Results show an uniform efficiency close to 100% along with a timing resolution of around 60 ps on the entire 2000 × 500 mm 2 area.
  •  
5.
  • Nacher, E., et al. (författare)
  • Proton response of CEPA4: A novel LaBr3(Ce)-LaCl3(Ce) phoswich array for high-energy gamma and proton spectroscopy
  • 2015
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 769, s. 105-111
  • Tidskriftsartikel (refereegranskat)abstract
    • A new phoswich array, for the detection of high-energy protons and gamma rays from nuclear reactions, has been built. This new detector consists of four individual closely packed scintillator detectors, each of them made of 4 cm of LaBr3(Ce) and G cm of LaCl3(Ce) in phoswich configuration (optically coupled and with a common readout). In this paper we report on the results of a beam test performed at the Bronowice Cyclotron Centre (CCB) in Krakow, showing the response of this versatile instrument to high energy protons (70-230 MeV). Furthermore, for the first time we prove that we can reconstruct the original energy of fast protons (E > 200 MeV) which pass through the total length of the crystal while still retaining a good energy resolution.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy