SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Marchesini Stefano) "

Sökning: WFRF:(Marchesini Stefano)

  • Resultat 1-10 av 31
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aquila, Andrew, et al. (författare)
  • Time-resolved protein nanocrystallography using an X-ray free-electron laser
  • 2012
  • Ingår i: Optics Express. - 1094-4087. ; 20:3, s. 2706-2716
  • Tidskriftsartikel (refereegranskat)abstract
    • We demonstrate the use of an X-ray free electron laser synchronized with an optical pump laser to obtain X-ray diffraction snapshots from the photoactivated states of large membrane protein complexes in the form of nanocrystals flowing in a liquid jet. Light-induced changes of Photosystem I-Ferredoxin co-crystals were observed at time delays of 5 to 10 µs after excitation. The result correlates with the microsecond kinetics of electron transfer from Photosystem I to ferredoxin. The undocking process that follows the electron transfer leads to large rearrangements in the crystals that will terminally lead to the disintegration of the crystals. We describe the experimental setup and obtain the first time-resolved femtosecond serial X-ray crystallography results from an irreversible photo-chemical reaction at the Linac Coherent Light Source. This technique opens the door to time-resolved structural studies of reaction dynamics in biological systems.
  •  
2.
  • Bajt, Sasa, et al. (författare)
  • Camera for coherent diffractive imaging and holography with a soft-x-ray free-electron laser
  • 2008
  • Ingår i: Applied Optics. - 1559-128X .- 2155-3165. ; 47:10, s. 1673-1683
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe a camera to record coherent scattering patterns with a soft-x-ray free-electron laser (FEL). The camera consists of a laterally graded multilayer mirror, which reflects the diffraction pattern onto a CCD detector. The mirror acts as a bandpass filter for both the wavelength and the angle, which isolates the desired scattering pattern from nonsample scattering or incoherent emission from the sample. The mirror also solves the particular problem of the extreme intensity of the FEL pulses, which are focused to greater than 10(14) W/cm2. The strong undiffracted pulse passes through a hole in the mirror and propagates onto a beam dump at a distance behind the instrument rather than interacting with a beam stop placed near the CCD. The camera concept is extendable for the full range of the fundamental wavelength of the free electron laser in Hamburg (FLASH) FEL (i.e., between 6 and 60 nm) and into the water window. We have fabricated and tested various multilayer mirrors for wavelengths of 32, 16, 13.5, and 4.5 nm. At the shorter wavelengths mirror roughness must be minimized to reduce scattering from the mirror. We have recorded over 30,000 diffraction patterns at the FLASH FEL with no observable mirror damage or degradation of performance.
  •  
3.
  • Barty, Anton, et al. (författare)
  • Ultrafast single-shot diffraction imaging of nanoscale dynamics
  • 2008
  • Ingår i: Nature Photonics. - : Springer Science and Business Media LLC. - 1749-4885 .- 1749-4893. ; 2:7, s. 415-419
  • Tidskriftsartikel (refereegranskat)abstract
    • The transient nanoscale dynamics of materials on femtosecond to picosecond timescales is of great interest in the study of condensed phase dynamics such as crack formation, phase separation and nucleation, and rapid fluctuations in the liquid state or in biologically relevant environments. The ability to take images in a single shot is the key to studying non-repetitive behaviour mechanisms, a capability that is of great importance in many of these problems. Using coherent diffraction imaging with femtosecond X-ray free-electron-laser pulses we capture time-series snapshots of a solid as it evolves on the ultrafast timescale. Artificial structures imprinted on a Si3N4 window are excited with an optical laser and undergo laser ablation, which is imaged with a spatial resolution of 50 nm and a temporal resolution of 10 ps. By using the shortest available free-electron-laser wavelengths(1) and proven synchronization methods(2) this technique could be extended to spatial resolutions of a few nanometres and temporal resolutions of a few tens of femtoseconds. This experiment opens the door to a new regime of time-resolved experiments in mesoscopic dynamics.
  •  
4.
  • Bogan, Michael J., et al. (författare)
  • Aerosol Imaging with a Soft X-Ray Free Electron Laser
  • 2010
  • Ingår i: Aerosol Science and Technology. - : Informa UK Limited. - 0278-6826 .- 1521-7388. ; 44:3, s. I-VI
  • Tidskriftsartikel (refereegranskat)abstract
    • Lasers have long played a critical role in the advancement of aerosol science. A new regime of ultrafast laser technology has recently be realized, the world's first soft x-ray free electron laser. The Free electron LASer in Hamburg, FLASH, user facility produces a steady source of 10 femtosecond pulses of 7–32 nm x-rays with 1012 photons per pulse. The high brightness, short wavelength, and high repetition rate (> 500 pulses per second) of this laser offers unique capabilities for aerosol characterization. Here we use FLASH to perform the highest resolution imaging of single PM2.5 aerosol particles in flight to date. We resolve to 35 nm the morphology of fibrous and aggregated spherical carbonaceous nanoparticles that existed for less than two milliseconds in vacuum. Our result opens the possibility for high spatial- and time-resolved single particle aerosol dynamics studies, filling a critical technological need in aerosol science.
  •  
5.
  • Bogan, Michael J, et al. (författare)
  • Single particle X-ray diffractive imaging
  • 2008
  • Ingår i: Nano letters (Print). - : American Chemical Society (ACS). - 1530-6984 .- 1530-6992. ; 8:1, s. 310-6
  • Tidskriftsartikel (refereegranskat)abstract
    • In nanotechnology, strategies for the creation and manipulation of nanoparticles in the gas phase are critically important for surface modification and substrate-free characterization. Recent coherent diffractive imaging with intense femtosecond X-ray pulses has verified the capability of single-shot imaging of nanoscale objects at suboptical resolutions beyond the radiation-induced damage threshold. By intercepting electrospray-generated particles with a single 15 femtosecond soft-X-ray pulse, we demonstrate diffractive imaging of a nanoscale specimen in free flight for the first time, an important step toward imaging uncrystallized biomolecules.
  •  
6.
  • Boutet, Sebastien, et al. (författare)
  • Ultrafast soft X-ray scattering and reference-enhanced diffractive imaging of weakly scattering nanoparticles
  • 2008
  • Ingår i: Journal of Electron Spectroscopy and Related Phenomena. - : Elsevier BV. - 0368-2048 .- 1873-2526. ; 166, s. 65-73
  • Tidskriftsartikel (refereegranskat)abstract
    • We report the first successful reconstruction of the real space image from coherent X-ray diffraction patterns of membrane-supported nanoparticles using single ultrafast pulses. The particles consisted of 145-nm spherical polystyrene spheres that were size-selected by differential mobility analysis. We investigated the dependence of signal intensity on the number of spherical nanoparticles irradiated by single ultrafast pulses at the FLASH FEL facility. We demonstrate detection of as few as two 145-nm diameter particles irradiated by a single 32 nm fs-long FLASH pulse focused to 2.4Jcm(-2). In this case the noise in the diffraction pattern. due to photon-counting statistics and scattering from the supporting silicon nitride membrane, was the largest contributor to the recorded intensity. We were able to reconstruct high-resolution images of the nanoparticles using a strong scattering reference object to aid the phase retrieval of the coherent diffraction pattern. This method of reference-enhanced diffractive imaging may allow the imaging of weakly scattering objects at FLASH and other future X-ray FEL sources.
  •  
7.
  • Chapman, Henry N., et al. (författare)
  • Femtosecond diffractive imaging with a soft-X-ray free-electron laser
  • 2006
  • Ingår i: Nature Physics. - : Springer Science and Business Media LLC. - 1745-2473 .- 1745-2481. ; 2:12, s. 839-843
  • Tidskriftsartikel (refereegranskat)abstract
    • Theory predicts(1-4) that, with an ultrashort and extremely bright coherent X-ray pulse, a single diffraction pattern may be recorded from a large macromolecule, a virus or a cell before the sample explodes and turns into a plasma. Here we report the first experimental demonstration of this principle using the FLASH soft-X-ray free-electron laser. An intense 25 fs, 4 x 10(13) W cm(-2) pulse, containing 10(12) photons at 32 nm wavelength, produced a coherent diffraction pattern from a nanostructured non-periodic object, before destroying it at 60,000 K. A novel X-ray camera assured single-photon detection sensitivity by filtering out parasitic scattering and plasma radiation. The reconstructed image, obtained directly from the coherent pattern by phase retrieval through oversampling(5-9), shows no measurable damage, and is reconstructed at the diffraction-limited resolution. A three-dimensional data set may be assembled from such images when copies of a reproducible sample are exposed to the beam one by one(10).
  •  
8.
  • Chapman, Henry N, et al. (författare)
  • Femtosecond time-delay X-ray holography
  • 2007
  • Ingår i: Nature. - : Springer Science and Business Media LLC. - 0028-0836 .- 1476-4687. ; 448:7154, s. 676-679
  • Tidskriftsartikel (refereegranskat)abstract
    • Extremely intense and ultrafast X-ray pulses from free-electron lasers offer unique opportunities to study fundamental aspects of complex transient phenomena in materials. Ultrafast time-resolved methods usually require highly synchronized pulses to initiate a transition and then probe it after a precisely defined time delay. In the X-ray regime, these methods are challenging because they require complex optical systems and diagnostics. Here we propose and apply a simple holographic measurement scheme, inspired by Newton's 'dusty mirror' experiment1, to monitor the X-ray-induced explosion of microscopic objects. The sample is placed near an X-ray mirror; after the pulse traverses the sample, triggering the reaction, it is reflected back onto the sample by the mirror to probe this reaction. The delay is encoded in the resulting diffraction pattern to an accuracy of one femtosecond, and the structural change is holographically recorded with high resolution. We apply the technique to monitor the dynamics of polystyrene spheres in intense free-electron-laser pulses, and observe an explosion occurring well after the initial pulse. Our results support the notion that X-ray flash imaging2, 3 can be used to achieve high resolution, beyond radiation damage limits for biological samples4. With upcoming ultrafast X-ray sources we will be able to explore the three-dimensional dynamics of materials at the timescale of atomic motion.
  •  
9.
  • Chapman, Henry N, et al. (författare)
  • Femtosecond X-ray protein nanocrystallography.
  • 2011
  • Ingår i: Nature. - : Springer Science and Business Media LLC. - 1476-4687 .- 0028-0836. ; 470:7332, s. 73-7
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray crystallography provides the vast majority of macromolecular structures, but the success of the method relies on growing crystals of sufficient size. In conventional measurements, the necessary increase in X-ray dose to record data from crystals that are too small leads to extensive damage before a diffraction signal can be recorded. It is particularly challenging to obtain large, well-diffracting crystals of membrane proteins, for which fewer than 300 unique structures have been determined despite their importance in all living cells. Here we present a method for structure determination where single-crystal X-ray diffraction 'snapshots' are collected from a fully hydrated stream of nanocrystals using femtosecond pulses from a hard-X-ray free-electron laser, the Linac Coherent Light Source. We prove this concept with nanocrystals of photosystem I, one of the largest membrane protein complexes. More than 3,000,000 diffraction patterns were collected in this study, and a three-dimensional data set was assembled from individual photosystem I nanocrystals (∼200 nm to 2 μm in size). We mitigate the problem of radiation damage in crystallography by using pulses briefer than the timescale of most damage processes. This offers a new approach to structure determination of macromolecules that do not yield crystals of sufficient size for studies using conventional radiation sources or are particularly sensitive to radiation damage.
  •  
10.
  • Daurer, Benedikt J., et al. (författare)
  • Nanosurveyor : a framework for real-time data processing
  • 2017
  • Ingår i: Advanced Structural and Chemical Imaging. - : Springer Science and Business Media LLC. - 2198-0926. ; 3:7
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The ever improving brightness of accelerator based sources is enabling novel observations and discov-eries with faster frame rates, larger fields of view, higher resolution, and higher dimensionality.Results: Here we present an integrated software/algorithmic framework designed to capitalize on high-throughput experiments through efficient kernels, load-balanced workflows, which are scalable in design. We describe the streamlined processing pipeline of ptychography data analysis.Conclusions: The pipeline provides throughput, compression, and resolution as well as rapid feedback to the micro-scope operators
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 31
Typ av publikation
tidskriftsartikel (29)
konferensbidrag (2)
Typ av innehåll
refereegranskat (30)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Marchesini, Stefano (28)
Barty, Anton (19)
Bogan, Michael J. (18)
Chapman, Henry N. (18)
Bajt, Saša (17)
Frank, Matthias (17)
visa fler...
Hajdu, Janos (14)
Maia, Filipe R. N. C ... (14)
Boutet, Sébastien (13)
Seibert, M Marvin (12)
Bostedt, Christoph (11)
Schulz, Joachim (10)
Shoeman, Robert L (9)
Liang, Mengning (9)
Lomb, Lukas (9)
Hau-Riege, Stefan P (9)
Caleman, Carl (8)
Aquila, Andrew (8)
Graafsma, Heinz (8)
Hirsemann, Helmut (8)
Erk, Benjamin (8)
Rudenko, Artem (8)
Rolles, Daniel (8)
Martin, Andrew V. (8)
Foucar, Lutz (8)
Hartmann, Robert (8)
Rudek, Benedikt (8)
White, Thomas A. (8)
Barthelmess, Miriam (8)
Coppola, Nicola (8)
Epp, Sascha W. (8)
Gumprecht, Lars (8)
Hampton, Christina Y ... (8)
Holl, Peter (8)
Kimmel, Nils (8)
Nass, Karol (8)
Reich, Christian (8)
Schlichting, Ilme (8)
Soltau, Heike (8)
Ullrich, Joachim (8)
Weidenspointner, Geo ... (8)
Spence, John C. H. (8)
Sierra, Raymond G. (7)
Doak, R Bruce (7)
Timneanu, Nicusor (7)
Hunter, Mark S. (7)
Fleckenstein, Holger (7)
Kassemeyer, Stephan (7)
Starodub, Dmitri (7)
Weierstall, Uwe (7)
visa färre...
Lärosäte
Uppsala universitet (28)
Göteborgs universitet (4)
Sveriges Lantbruksuniversitet (4)
Lunds universitet (3)
Umeå universitet (1)
Stockholms universitet (1)
Språk
Engelska (31)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (27)
Medicin och hälsovetenskap (3)
Lantbruksvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy