SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Olerud Claes)
 

Sökning: WFRF:(Olerud Claes) > Fahlstedt Madelen > Finite element anal...

Finite element analysis of long posterior transpedicular instrumentation for cervicothoracic fractures related to ankylosing spondylitis

Robinson, Yohan, 1977- (författare)
Uppsala universitet,Ortopedi,Uppsala University Hospital, Uppsala, Sweden
Lison Almkvist, Viktor (författare)
KTH,Neuronik,KTH Stockholm
Fahlstedt, Madelen, 1983- (författare)
KTH,Neuronik,KTH Stockholm
visa fler...
Olerud, Claes (författare)
Uppsala universitet,Ortopedi,Uppsala University Hospital, Uppsala, Sweden
Halldin, Peter (författare)
KTH,Neuronik,KTH Stockholm
visa färre...
 (creator_code:org_t)
2018-01-30
2018
Engelska.
Ingår i: Global Spine Journal. - : SAGE Publications. - 2192-5682 .- 2192-5690. ; 8:6, s. 570-578
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Spinal fractures related to AS are often treated by long posterior stabilisation. The biomechanical rationale behind is the neutralisation of long lever arms in the ankylosed spine to avoid non-union or neurological deterioration. Despite the widespread application of long posterior instrumentation it has never been investigated in a biomechanical model. The objective of this study is to develop a finite element model for spinal fractures related to AS and to establish a biomechanical foundation for long posterior stabilisation of cervicothoracic fractures related to ankylosing spondylitis (AS).Methods: An existing finite element-model (consisting of two separately developed models) including the cervical and thoracic spine were adapted to the conditions of AS (all discs fused, C0-C1 and C1-C2 mobile) and a fracture at the level C6-C7 was simulated. Besides a normal spine (no AS, no fracture) and the uninstrumented fractured spine four different posterior transpedicular instrumentations were tested: 1. Fracture uninstrumented, 2. Short instrumentation C6-C7, 3. Medium instrumentation C5-T1, 4. Long instrumentation C3-T3, 5. Skipped level long instrumentation C3-C6-C7-T3.Three loads (1.5g, 3.0g, 4.5g) were applied according to a specific load curve. Kinematic data such as the gap distance in the fracture site were obtained. Furthermore the stresses in the ossified parts of the discs were evaluated.Findings: All posterior stabilisation methods could normalise the axial stability at the fracture site as measured with gap distance. With larger accelerations than 1.5g ,  it was seen that the longer instrumentations resulted in lesser maximal gap distance than the Short instrumentation. The maximum stress at the cranial instrumentation end (C3-C4) was slightly greater if every level was instrumented, than in the skipped level model. The skipped level instrumentation achieved similar rotatory stability as the long multilevel instrumentation.Interpretation: The FE model developed simulated a spinal fracture at C6-C7 level. Skipping instrumentation levels without giving up instrumentation length also reduces the stresses in the ossified tissue within the range of the instrumentation and does not decrease the stability in a finite element model of a cervicothoracic fracture related to AS. Considering the risks associated with every additional screw placed, the skipped level instrumentation has advantages with regard to patient safety. The effects of the degree of osteoporosis, screw placement and pre-existing kyphosis on the construct stability were not investigated in this study and should be a matter of further research. 

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik -- Biomaterial (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology -- Bio Materials (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Nyckelord

Orthopaedics
Ortopedi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng