SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Pfeiffer M.) ;lar1:(miun)"

Sökning: WFRF:(Pfeiffer M.) > Mittuniversitetet

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Christensen, M. J., et al. (författare)
  • Software-based data acquisition and processing for neutron detectors at European Spallation Source-early experience from four detector designs
  • 2018
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 13:11
  • Tidskriftsartikel (refereegranskat)abstract
    • European Spallation Source (ESS) will deliver neutrons at high flux for use in diverse neutron scattering techniques. The neutron source facility and the scientific instruments will be located in Lund, and the Data Management and Software Centre (DMSC), in Copenhagen. A number of detector prototypes are being developed at ESS together with its European in-kind partners, for example: SoNDe, Multi-Grid, Multi-Blade and Gd-GEM. These are all position sensitive detectors but use different techniques for the detection of neutrons. Except for digitization of electronics readout, all neutron data is anticipated to be processed in software. This provides maximum flexibility and adaptability and allows deep inspection of the raw data for commissioning which will reduce the risk of starting up new detector technologies. But it also requires development of high performance software processing pipelines and optimized and scalable processing algorithms. This report provides a description of the ESS system architecture for the neutron data path. Special focus is on the interface between the detectors and DMSC which is based on UDP over Ethernet links. The report also describes the software architecture for detector data processing and the tools we have developed, which have proven very useful for efficient early experimentation, and can be run on a single laptop. Processing requirements for the SoNDe, Multi-Grid, Multi-Blade and Ge-GEM detectors are presented and compared to event processing rates archived so far.
  •  
2.
  • Kirstein, Oliver, et al. (författare)
  • Neutron position sensitive detectors for the ESS
  • 2014
  • Ingår i: Proceedings of Science. - : Proceedings of Science (PoS). ; Vertex2014, s. 029-029
  • Konferensbidrag (refereegranskat)abstract
    • The European Spallation Source (ESS) in Lund, Sweden will become the world's leading neutron source for the study of materials. It will be a long pulse source, with an average beam power of 5 MW delivered to the target station. The ESS is in the construction phase, which started in 2013 with the completion of the Technical Design Report (TDR). The instruments are being selected from conceptual proposals submitted by groups from around Europe. These instruments present numerous challenges for detector technology in the absence of the availability of Helium-3, which is the default choice for detectors for instruments built until today and due to the extreme rates expected across the ESS instrument suite. Additionally a new generation of source requires a new generation of detector technologies to fully exploit the opportunities that this source provides. To meet this challenge at a green-field site, the detectors will be sourced from partners across Europe through numerous in-kind arrangements; a process that is somewhat novel for the neutron scattering community. This contribution presents briefly the current status of detectors for the ESS, and outlines the timeline to completion. For a conjectured instrument suite based upon instruments recommended for construction, a recently updated snapshot of the current expected detector requirements is presented. A strategy outline as to how these requirements might be tackled by novel detector developments is shown. In terms of future developments for the neutron community, synergies should be sought with other disciples, as recognized by various recent initiatives in Europe, in the context of the fundamentally multi-disciplinary nature of detectors. This strategy has at its basis the in-kind and collaborative partnerships necessary to be able to produce optimally performant detectors that allow the ESS instruments to be world-leading. This foresees and encourages a high level of collaboration and interdependence at its core, and rather than each group being all-rounders in every technology, the further development of centres of excellence across Europe for particular technologies and niches.
  •  
3.
  •  
4.
  • Dijulio, Douglas D., et al. (författare)
  • Characterization of the radiation background at the Spallation Neutron Source
  • 2016
  • Ingår i: VI European Conference On Neutron Scattering (ECNS2015). - : IOP Publishing. ; 746:1
  • Konferensbidrag (refereegranskat)abstract
    • We present a survey of the radiation background at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory, TN, USA during routine daily operation. A broad range of detectors was used to characterize primarily the neutron and photon fields throughout the facility. These include a WENDI-2 extended range dosimeter, a thermoscientific NRD, an Arktis He-4 detector, and a standard Nal photon detector. The information gathered from the detectors was used to map out the neutron dose rates throughout the facility and also the neutron dose rate and flux profiles of several different beamlines. The survey provides detailed information useful for developing future shielding concepts at spallation neutron sources, such as the European Spallation Source (ESS), currently under construction in Lund, Sweden.
  •  
5.
  • Pfeiffer, D., et al. (författare)
  • First measurements with new high-resolution gadolinium-GEM neutron detectors
  • 2016
  • Ingår i: Journal of Instrumentation. - : IOP PUBLISHING LTD. - 1748-0221. ; 11
  • Tidskriftsartikel (refereegranskat)abstract
    • European Spallation Source instruments like the macromolecular diffractometer (NMX) require an excellent neutron detection efficiency, high-rate capabilities, time resolution, and an unprecedented spatial resolution in the order of a few hundred micrometers over a wide angular range of the incoming neutrons. For these instruments solid converters in combination with Micro Pattern Gaseous Detectors (MPGDs) are a promising option. A GEM detector with gadolinium converter was tested on a cold neutron beam at the IFE research reactor in Norway. The mu TPC analysis, proven to improve the spatial resolution in the case of B-10 converters, is extended to gadolinium based detectors. For the first time, a Gd-GEM was successfully operated to detect neutrons with a measured efficiency of 11.8% at a wavelength of 2 angstrom and a position resolution better than 250 mu m.
  •  
Skapa referenser, mejla, bekava och länka