SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Qian Cheng) ;lar1:(oru)"

Sökning: WFRF:(Qian Cheng) > Örebro universitet

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Han, Hedong, et al. (författare)
  • Comparison of In-Hospital Mortality and Length of Stay in Acute ST-Segment-Elevation Myocardial Infarction Among Urban Teaching Hospitals in China and the United States
  • 2019
  • Ingår i: Journal of the American Heart Association. - : Wiley-Blackwell Publishing Inc.. - 2047-9980 .- 2047-9980. ; 8:22
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The aim of the study is to compare in-hospital outcomes of acute ST-segment–elevation myocardial infarction (STEMI) between China and the United States.Methods and Results: Urban teaching hospitals were queried for adult patients with a primary diagnosis of acute STEMI during 2007–2010. The primary outcome was in-hospital mortality, and the secondary outcome was length of stay. Multivariable analyses adjusting for potential confounders were conducted for comparison between countries. Subgroup analysis was performed in acute STEMI patients receiving revascularization. In total, 32 228 patients in China and 76 117 patients in the United States were included. Overall in-hospital mortality was 8.23% in China and 7.96% in the United States (P<0.001). Multivariable analyses revealed that the 2 countries had similar overall in-hospital mortality (odds ratio, 0.97; 95% CI, 0.87–1.09; P=0.59), whereas China had lower 3-day mortality (odds ratio, 0.78; 95% CI, 0.70–0.89; P<0.001). In patients receiving primary percutaneous coronary interventions, Chinese hospitals had significant higher overall mortality (odds ratio, 2.39; 95% CI, 1.85–3.07; P<0.001) and 3-day mortality (odds ratio, 2.39; 95% CI, 1.78–3.20; P<0.001). For total acute STEMI patients, acute STEMI patients receiving percutaneous coronary intervention and coronary artery bypass grafting, median length of stay in China and the United States were 10 versus 3, 9 versus 3, and 25 versus 9 days, respectively (all P<0.001).Conclusions: Overall in-hospital mortality in acute STEMI patients was comparable among urban teaching hospitals between China and the United States during 2007-2010. In addition, 3-day mortality was lower in China. However, worse outcomes in patients undergoing early revascularization and longer length of stay in China need to be given more attention.
  •  
2.
  • Jin, Zhichao, et al. (författare)
  • A retrospective survey of research design and statistical analyses in selected Chinese medical journals in 1998 and 2008
  • 2010
  • Ingår i: PLOS ONE. - : PLOS. - 1932-6203. ; 5:5
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: High quality clinical research not only requires advanced professional knowledge, but also needs sound study design and correct statistical analyses. The number of clinical research articles published in Chinese medical journals has increased immensely in the past decade, but study design quality and statistical analyses have remained suboptimal. The aim of this investigation was to gather evidence on the quality of study design and statistical analyses in clinical researches conducted in China for the first decade of the new millennium.METHODOLOGY/PRINCIPAL FINDINGS: Ten (10) leading Chinese medical journals were selected and all original articles published in 1998 (N = 1,335) and 2008 (N = 1,578) were thoroughly categorized and reviewed. A well-defined and validated checklist on study design, statistical analyses, results presentation, and interpretation was used for review and evaluation. Main outcomes were the frequencies of different types of study design, error/defect proportion in design and statistical analyses, and implementation of CONSORT in randomized clinical trials. From 1998 to 2008: The error/defect proportion in statistical analyses decreased significantly ( = 12.03, p<0.001), 59.8% (545/1,335) in 1998 compared to 52.2% (664/1,578) in 2008. The overall error/defect proportion of study design also decreased ( = 21.22, p<0.001), 50.9% (680/1,335) compared to 42.40% (669/1,578). In 2008, design with randomized clinical trials remained low in single digit (3.8%, 60/1,578) with two-third showed poor results reporting (defects in 44 papers, 73.3%). Nearly half of the published studies were retrospective in nature, 49.3% (658/1,335) in 1998 compared to 48.2% (761/1,578) in 2008. Decreases in defect proportions were observed in both results presentation ( = 93.26, p<0.001), 92.7% (945/1,019) compared to 78.2% (1023/1,309) and interpretation ( = 27.26, p<0.001), 9.7% (99/1,019) compared to 4.3% (56/1,309), some serious ones persisted.CONCLUSIONS/SIGNIFICANCE: Chinese medical research seems to have made significant progress regarding statistical analyses, but there remains ample room for improvement regarding study designs. Retrospective clinical studies are the most often used design, whereas randomized clinical trials are rare and often show methodological weaknesses. Urgent implementation of the CONSORT statement is imperative.
  •  
3.
  • Liu, Qian, et al. (författare)
  • Graphenized pencil lead fiber : facile preparation and application in solid-phase microextraction
  • 2014
  • Ingår i: Journal of Chromatography A. - : Elsevier. - 0021-9673 .- 1873-3778. ; 1325, s. 1-7
  • Tidskriftsartikel (refereegranskat)abstract
    • Graphenized pencil lead fiber was facilely prepared by in situ chemical exfoliation of graphite in pencil lead fiber to few-layered graphene sheets via a one-pot, one-step pressurized oxidation reaction for the first time. This new fiber was characterized and demonstrated to be a highly efficient but low-cost solid-phase microextraction (SPME) fiber. The extraction performance of the fiber was evaluated with four bisphenol analogs [bisphenol A (BPA), bisphenol S (BPS), bisphenol AF (BPAF), and tetrabromobisphenol A (TBBPA)] as model analytes in direct SPME mode. Unlike commercially available fibers, the graphenized pencil lead fiber showed an excellent chemical stability in highly saline, acidic, alkaline and organic conditions due to its coating-free configuration. The fiber also showed a very long lifespan. Furthermore, high extraction efficiency and good selectivity for the analytes with a wide polarity range could be obtained due to the exceptional properties of graphene. The detection limits (LODs) for the analytes were in the range of 1.1-25ng/L. The fiber was successfully applied in the analysis of tap water and effluent samples from a waste water treatment plant with spike recoveries ranging from 68.5 to 105.1%. Therefore, the graphenized pencil lead fiber provides a high performance, cheap, robust, and reliable tool for SPME.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy