SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Roffi Marco) ;lar1:(oru)"

Sökning: WFRF:(Roffi Marco) > Örebro universitet

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Doolub, Gemina, et al. (författare)
  • Impact of Sex on Clinical Outcomes in Patients undergoing Complex Percutaneous Coronary Angioplasty (from the e-ULTIMASTER Study)
  • 2023
  • Ingår i: American Journal of Cardiology. - : Elsevier. - 0002-9149 .- 1879-1913. ; 186, s. 71-79
  • Tidskriftsartikel (refereegranskat)abstract
    • Female gender has been shown to be associated with worse clinical outcomes after percutaneous coronary intervention (PCI). However, the impact of gender on the clinical outcomes of complex PCI is still poorly understood. This study examined the differences in patient and coronary lesion characteristics and longer-term clinical outcomes in male and female patients who underwent complex PCI. This was a sub-analysis of the e-ULTIMASTER study, which was a large, multicontinental, prospective, observational study enrolling 37,198 patients who underwent PCI with the Ultimaster stent. Patients who underwent complex PCI were stratified by gender. The primary outcome was target lesion failure at 12 months, defined as the composite of cardiac death, target vessel-related myocardial infarction, and clinically driven target lesion revascularization at 12 months. A total of 13,623 patients underwent complex procedures, of which 35.7% were women. Women were twice as likely as men to be aged ≥80 years (17.6% vs 9%, p <0.0001) and had a higher prevalence of cardiovascular risk factors. Women had fewer lesions treated than men (1.5 ± 0.8 vs 1.6 ± 0.8, p <0.0001) and fewer stents implanted (2.0 ± 1.1 vs 2.1 ± 1.1, p <0.0001). There was no statistically significant difference in clinical outcomes at 12 months between women and men. Event rates were comparable in women and men for target lesion failure (4.7% vs 4.3%, p = 0.30), target vessel failure (5.1% vs 4.9%, p = 0.73), and cardiac death (1.8% vs 1.7%, p = 0.80).In conclusion, our findings suggest no significant differences in clinical outcomes between women and men who underwent complex PCI.
  •  
2.
  • Kobo, Ofer, et al. (författare)
  • Impact of Multisite artery disease on Clinical Outcomes After Percutaneous Coronary Intervention : An Analysis from the e-Ultimaster Registry
  • 2023
  • Ingår i: European Heart Journal - Quality of Care and Clinical Outcomes. - : Oxford University Press. - 2058-5225 .- 2058-1742. ; 9:4, s. 417-426
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Multisite artery disease is considered a 'malignant' type of atherosclerotic disease associated with an increased cardiovascular risk, but the impact of multisite artery disease on clinical outcomes after percutaneous coronary intervention (PCI) is unknown.METHODS: Patients enrolled in the large, prospective e-Ultimaster study were grouped into 1) those without known prior vascular disease; 2) those with known single-territory vascular disease 3) those with known 2-3 territories (i.e, coronary, cerebrovascular, or peripheral) vascular disease (multisite artery disease). The primary outcome was coronary target lesion failure (TLF) defined as the composite of cardiac death, target vessel-related myocardial infarction, and clinically driven target lesion revascularization at 1-year. Inverse propensity score weighted (IPSW) analysis was performed to address differences in baseline patient and lesion characteristics.RESULTS: Of the 37,198 patients included in the study, 62.3% had no prior known vascular disease, 32.6% had single-territory vascular disease, and 5.1% multisite artery disease. Patients with known vascular disease were older and were more likely to be men and to have more co-morbidities. After IPSW, the TLF rate incrementally increased with the number of diseased vascular beds (3.16%, 4.44% and 6.42% for no, single- and multisite artery disease, p<0.01 for all comparisons). This was also true for all cause death (2.22%, 3.28% and 5.29%, p<0.01 for all comparisons) and cardiac mortality (1.26%, 1.91% and 3.62%, p≤0.01 for all comparisons).CONCLUSIONS: Patients with previously known vascular disease experienced an increased risk for adverse cardiovascular events and mortality post percutaneous coronary intervention. This risk is highest among patients with multisite artery disease.
  •  
3.
  • Mamas, Mamas A., et al. (författare)
  • Predicting target lesion failure following percutaneous coronary intervention through machine learning risk assessment models
  • 2023
  • Ingår i: The European Heart Journal - Digital Health. - : Oxford University Press. - 2634-3916. ; 4:6, s. 433-443
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: Central to the practice of precision medicine in percutaneous coronary intervention (PCI) is a risk-stratification tool to predict outcomes following the procedure. This study is intended to assess machine learning (ML)-based risk models to predict clinically relevant outcomes in PCI and to support individualized clinical decision-making in this setting.METHODS AND RESULTS: Five different ML models [gradient boosting classifier (GBC), linear discrimination analysis, Naïve Bayes, logistic regression, and K-nearest neighbours algorithm) for the prediction of 1-year target lesion failure (TLF) were trained on an extensive data set of 35 389 patients undergoing PCI and enrolled in the global, all-comers e-ULTIMASTER registry. The data set was split into a training (80%) and a test set (20%). Twenty-three patient and procedural characteristics were used as predictive variables. The models were compared for discrimination according to the area under the receiver operating characteristic curve (AUC) and for calibration. The GBC model showed the best discriminative ability with an AUC of 0.72 (95% confidence interval 0.69-0.75) for 1-year TLF on the test set. The discriminative ability of the GBC model for the components of TLF was highest for cardiac death with an AUC of 0.82, followed by target vessel myocardial infarction with an AUC of 0.75 and clinically driven target lesion revascularization with an AUC of 0.68. The calibration was fair until the highest risk deciles showed an underestimation of the risk. CONCLUSION: Machine learning-derived predictive models provide a reasonably accurate prediction of 1-year TLF in patients undergoing PCI. A prospective evaluation of the predictive score is warranted.REGISTRATION: Clinicaltrial.gov identifier is NCT02188355.
  •  
4.
  • Vlieger, Selina, et al. (författare)
  • One-year performance of thin-strut cobalt chromium sirolimus-eluting stent versus thicker strut stainless steel biolimus-eluting coronary stent : a propensity-matched analysis of two international all-comers registries
  • 2021
  • Ingår i: Coronary Artery Disease. - : Lippincott Williams & Wilkins. - 0954-6928 .- 1473-5830. ; 32:5, s. 391-396
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: Recent improvements in coronary stent design have focussed on thinner struts, different alloys and architecture, more biocompatible polymers, and shorter drug absorption times. This study evaluates safety and efficacy of a newer generation thin-strut cobalt chromium sirolimus-eluting coronary stent (SES, Ultimaster) in comparison with a second-generation thicker strut stainless steel biolimus-eluting stent (BES, Nobori) in percutaneous coronary intervention (PCI) practice.METHODS: A propensity score analysis was performed to adjust for differences in baseline characteristics of 8137 SES patients and 2738 BES patients of two PCI registries (e-Ultimaster and NOBORI 2). An independent clinical event committee adjudicated all endpoint-related adverse events.RESULTS: The use of SES, as compared with BES was associated with a significantly lower rate of myocardial infarction (MI) (1.2% vs 2.2%; P = 0.0006) and target vessel-related MI (1.1% vs 1.8%; P = 0.002) at 1 year. One-year composite endpoints of all predefined endpoints were lower in patients undergoing SES implantation (target lesion failure: 3.2% vs 4.1%; P = 0.03, target vessel failure: 3.7% vs 5.0%; P = 0.003, patient-oriented composite endpoint 5.7% vs 6.8%; P = 0.03). No significant differences between SES and BES were observed in all-cause death (2.0% vs 1.6%; P = 0.19), cardiac death (1.2% vs 1.2%; P = 0.76) or stent thrombosis (0.6% vs 0.8%; P = 0.43).CONCLUSIONS: These findings suggest an improved clinical safety and efficacy of a newer generation thin-strut SES as compared with a second-generation thicker strut BES.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy