SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Ruggeri A) srt2:(2015-2019);lar1:(liu)"

Search: WFRF:(Ruggeri A) > (2015-2019) > Linköping University

  • Result 1-4 of 4
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Abe, K., et al. (author)
  • J-PARC Neutrino Beamline Upgrade Technical Design Report
  • 2019
  • Reports (peer-reviewed)abstract
    • In this document, technical details of the upgrade plan of the J-PARC neutrino beamline for the extension of the T2K experiment are described. T2K has proposed to accumulate data corresponding to 2×1022 protons-on-target in the next decade, aiming at an initial observation of CP violation with 3σ or higher significance in the case of maximal CP violation. Methods to increase the neutrino beam intensity, which are necessary to achieve the proposed data increase, are described.
  •  
2.
  • Lagali, Neil, et al. (author)
  • Focused Tortuosity Definitions Based on Expert Clinical Assessment of Corneal Subbasal Nerves
  • 2015
  • In: Investigative Ophthalmology and Visual Science. - : ASSOC RESEARCH VISION OPHTHALMOLOGY INC. - 0146-0404 .- 1552-5783. ; 56:9, s. 5102-5109
  • Journal article (peer-reviewed)abstract
    • PURPOSE. We examined agreement among experts in the assessment of corneal subbasal nerve tortuosity. METHODS. Images of corneal subbasal nerves were obtained from investigators at seven sites (Auckland, Boston, Linkoping, Manchester, Oslo, Rostock, and Sydney) using laser-scanning in vivo confocal microscopy. A set of 30 images was assembled and ordered by increasing tortuosity by 10 expert graders from the seven sites. In a first experiment, graders assessed tortuosity without a specific definition and performed grading three times, with at least 1 week between sessions. In a second experiment, graders assessed the same image set using four focused tortuosity definitions. Intersession and intergrader repeatability for the experiments were determined using the Spearman rank correlation. RESULTS. Expert graders without a specific tortuosity definition had high intersession (Spearman correlation coefficient 0.80), but poor intergrader (0.62) repeatability. Specific definitions improved intergrader repeatability to 0.79. In particular, tortuosity defined by frequent small-amplitude directional changes (short range tortuosity) or by infrequent large-amplitude directional changes (long range tortuosity), indicated largely independent measures and resulted in improved repeatability across the graders. A further refinement, grading only the most tortuous nerve in a given image, improved the average correlation of a given graders ordering of images with the group average to 0.86 to 0.90. CONCLUSIONS. Definitions of tortuosity specifying short or long-range tortuosity and considering only the most tortuous nerve in an image improved the agreement in tortuosity grading among a group of expert observers. These definitions could improve accuracy and consistency in quantifying subbasal nerve tortuosity in clinical studies.
  •  
3.
  • Lagali, Neil S, 1973-, et al. (author)
  • Reduced Corneal Nerve Fiber Density in Type 2 Diabetes by Wide-Area Mosaic Analysis
  • 2017
  • In: Investigative Ophthalmology and Visual Science. - : The Assocation for Research in Vision and Ophthalmology. - 0146-0404 .- 1552-5783. ; 58:14, s. 6318-6327
  • Journal article (peer-reviewed)abstract
    • PURPOSE. To determine if corneal subbasal nerve plexus (SBP) parameters derived from wide-area depth-corrected mosaic images are associated with type 2 diabetes.METHODS. One hundred sixty-three mosaics were produced from eyes of 82 subjects by laser-scanning in vivo confocal microscopy (IVCM). Subjects were of the same age, without (43 subjects) or with type 2 diabetes (39 subjects). Mosaic corneal nerve fiber length density (mCNFL) and apical whorl corneal nerve fiber length density (wCNFL) were quantified and related to the presence and duration of diabetes (short duration < 10 years and long duration ≥10 years).RESULTS. In mosaics with a mean size of 6 mm2 in subjects aged 69.1 ± 1.2 years, mCNFL in type 2 diabetes was reduced relative to nondiabetic subjects (13.1 ± 4.2 vs. 15.0 ± 3.2 mm/mm2, P = 0.018). Also reduced relative to nondiabetic subjects was mCNFL in both short-duration (14.0 ± 4.0 mm/mm2, 3.2 ± 3.9 years since diagnosis) and long-duration diabetes (12.7 ± 4.2 mm/mm2, 15.4 ± 4.2 years since diagnosis; ANOVA P =0.023). Lower mCNFL was associated with presence of diabetes (P =0.032) and increased hemoglobin A1c (HbA1c) levels (P = 0.047). By contrast, wCNFL was unaffected by diabetes or HbA1c (P > 0.05). Global SBP patterns revealed marked degeneration of secondary nerve fiber branches outside the whorl region in long-duration diabetes.CONCLUSIONS. Wide-area mosaic images provide reference values for mCNFL and wCNFL and reveal a progressive degeneration of the SBP with increasing duration of type 2 diabetes.
  •  
4.
  • Lagali, Neil, et al. (author)
  • Wide-field corneal subbasal nerve plexus mosaics in age-controlled healthy and type 2 diabetes populations
  • 2018
  • In: Scientific Data. - : Nature Publishing Group. - 2052-4463. ; 5
  • Journal article (peer-reviewed)abstract
    • A dense nerve plexus in the clear outer window of the eye, the cornea, can be imaged in vivo to enable non-invasive monitoring of peripheral nerve degeneration in diabetes. However, a limited field of view of corneal nerves, operator-dependent image quality, and subjective image sampling methods have led to difficulty in establishing robust diagnostic measures relating to the progression of diabetes and its complications. Here, we use machine-based algorithms to provide wide-area mosaics of the corneas subbasal nerve plexus (SBP) also accounting for depth (axial) fluctuation of the plexus. Degradation of the SBP with age has been mitigated as a confounding factor by providing a dataset comprising healthy and type 2 diabetes subjects of the same age. To maximize reuse, the dataset includes bilateral eye data, associated clinical parameters, and machine-generated SBP nerve density values obtained through automatic segmentation and nerve tracing algorithms. The dataset can be used to examine nerve degradation patterns to develop tools to non-invasively monitor diabetes progression while avoiding narrow-field imaging and image selection biases.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-4 of 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view