SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Scheible R) ;conttype:(refereed)"

Sökning: WFRF:(Scheible R) > Refereegranskat

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Maccari, Maria Elena, et al. (författare)
  • Activated phosphoinositide 3-kinase δ syndrome: Update from the ESID Registry and comparison with other autoimmune-lymphoproliferative inborn errors of immunity.
  • 2023
  • Ingår i: The Journal of allergy and clinical immunology. - 1097-6825. ; 152:4, s. 984-996.e10
  • Tidskriftsartikel (refereegranskat)abstract
    • Activated phosphoinositide-3-kinase δ syndrome (APDS) is an inborn error of immunity (IEI) with infection susceptibility and immune dysregulation, clinically overlapping with other conditions. Management depends on disease evolution, but predictors of severe disease are lacking.This study sought to report the extended spectrum of disease manifestations in APDS1 versus APDS2; compare these to CTLA4 deficiency, NFKB1 deficiency, and STAT3 gain-of-function (GOF) disease; and identify predictors of severity in APDS.Data was collected from the ESID (European Society for Immunodeficiencies)-APDS registry and was compared with published cohorts of the other IEIs.The analysis of 170 patients with APDS outlines high penetrance and early onset of APDS compared to the other IEIs. The large clinical heterogeneity even in individuals with the same PIK3CD variant E1021K illustrates how poorly the genotype predicts the disease phenotype and course. The high clinical overlap between APDS and the other investigated IEIs suggests relevant pathophysiological convergence of the affected pathways. Preferentially affected organ systems indicate specific pathophysiology: bronchiectasis is typical of APDS1; interstitial lung disease and enteropathy are more common in STAT3 GOF and CTLA4 deficiency. Endocrinopathies are most frequent in STAT3 GOF, but growth impairment is also common, particularly in APDS2. Early clinical presentation is a risk factor for severe disease in APDS.APDS illustrates how a single genetic variant can result in a diverse autoimmune-lymphoproliferative phenotype. Overlap with other IEIs is substantial. Some specific features distinguish APDS1 from APDS2. Early onset is a risk factor for severe disease course calling for specific treatment studies in younger patients.
  •  
2.
  • Tomas, C, et al. (författare)
  • Autosomal SNP typing of forensic samples with the GenPlex (TM) HID System: Results of a collaborative study
  • 2011
  • Ingår i: Forensic Science International. - : Elsevier. - 1872-4973 .- 1878-0326. ; 5:5, s. 369-375
  • Tidskriftsartikel (refereegranskat)abstract
    • The GenPlex (TM) HID System (Applied Biosystems - AB) offers typing of 48 of the 52 SNPforID SNPs and amelogenin. Previous studies have shown a high reproducibility of the GenPlex (TM) HID System using 250500 pg DNA of good quality. An international exercise was performed by 14 laboratories (9 in Europe and 5 in the US) in order to test the robustness and reliability of the GenPlex (TM) HID System on forensic samples. Three samples with partly degraded DNA and 10 samples with low amounts of DNA were analyzed in duplicates using various amounts of DNA. In order to compare the performance of the GenPlex (TM) HID System with the most commonly used STR kits, 500 pg of partly degraded DNA from three samples was typed by the laboratories using one or more STR kits. The median SNP typing success rate was 92.3% with 500 pg of partly degraded DNA. Three of the fourteen laboratories counted for more than two thirds of the locus dropouts. The median percentage of discrepant results was 0.2% with 500 pg degraded DNA. An increasing percentage of locus dropouts and discrepant results were observed when lower amounts of DNA were used. Different success rates were observed for the various SNPs. The rs763869 SNP was the least successful. With the exception of the MiniFiler (TM) kit (AB), GenPlex (TM) HID performed better than five other tested STR kits. When partly degraded DNA was analyzed, GenPlex (TM) HID showed a very low mean mach probability, while all STR kits except MiniFiler (TM) had very limited discriminatory power.
  •  
3.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy