SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Serruys Patrick W) ;pers:(Escaned Javier)"

Sökning: WFRF:(Serruys Patrick W) > Escaned Javier

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Iqbal, Javaid, et al. (författare)
  • Optimal Medical Therapy Improves Clinical Outcomes in Patients Undergoing Revascularization With Percutaneous Coronary Intervention or Coronary Artery Bypass Grafting Insights From the Synergy Between Percutaneous Coronary Intervention With TAXUS and Cardiac Surgery (SYNTAX) Trial at the 5-Year Follow-Up
  • 2015
  • Ingår i: Circulation. - 0009-7322 .- 1524-4539. ; 131:14, s. 1269-1277
  • Tidskriftsartikel (refereegranskat)abstract
    • Background-There is a paucity of data on the use of optimal medical therapy (OMT) in patients with complex coronary artery disease undergoing revascularization with percutaneous coronary intervention or coronary artery bypass grafting (CABG) and its long-term prognostic significance. Methods and Results-The Synergy Between Percutaneous Coronary Intervention With TAXUS and Cardiac Surgery (SYNTAX) trial is a multicenter, randomized, clinical trial of patients (n=1800) with complex coronary disease randomized to revascularization with percutaneous coronary intervention or CABG. Detailed drug history was collected for all patients at discharge and at the 1-month, 6-month, 1-year, 3-year, and 5-year follow-ups. OMT was defined as the combination of at least 1 antiplatelet drug, statin, beta-blocker, and angiotensin-converting enzyme inhibitor/angiotensin receptor blocker. Five-year clinical outcomes were stratified by OMT and non-OMT. OMT was underused in patients treated with coronary revascularization, especially CABG. OMT was an independent predictor of survival. OMT was associated with a significant reduction in mortality (hazard ratio, 0.64; 95% confidence interval, 0.48-0.85; P=0.002) and composite end point of death/myocardial infarction/stroke (hazard ratio, 0.73; 95% confidence interval, 0.58-0.92; P=0.007) at the 5-year follow-up. The treatment effect with OMT (36% relative reduction in mortality over 5 years) was greater than the treatment effect of revascularization strategy (26% relative reduction in mortality with CABG versus percutaneous coronary intervention over 5 years). On stratified analysis, all the components of OMT were important for reducing adverse outcomes regardless of revascularization strategy. Conclusions-The use of OMT remains low in patients with complex coronary disease requiring coronary intervention with percutaneous coronary intervention and even lower in patients treated with CABG. Lack of OMT is associated with adverse clinical outcomes. Targeted strategies to improve OMT use in postrevascularization patients are warranted.
  •  
2.
  • Ahmad, Yousif, et al. (författare)
  • Determining the Predominant Lesion in Patients With Severe Aortic Stenosis and Coronary Stenoses : A Multicenter Study Using Intracoronary Pressure and Flow
  • 2019
  • Ingår i: Circulation. Cardiovascular Interventions. - 1941-7632. ; 12:12
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Patients with severe aortic stenosis (AS) often have coronary artery disease. Both the aortic valve and the coronary disease influence the blood flow to the myocardium and its ability to respond to stress; leading to exertional symptoms. In this study, we aim to quantify the effect of severe AS on the coronary microcirculation and determine if this is influenced by any concomitant coronary disease. We then compare this to the effect of coronary stenoses on the coronary microcirculation. METHODS: Group 1: 55 patients with severe AS and intermediate coronary stenoses treated with transcatheter aortic valve implantation (TAVI) were included. Group 2: 85 patients with intermediate coronary stenoses and no AS treated with percutaneous coronary intervention were included. Coronary pressure and flow were measured at rest and during hyperemia in both groups, before and after TAVI (group 1) and before and after percutaneous coronary intervention (group 2). RESULTS: Microvascular resistance over the wave-free period of diastole increased significantly post-TAVI (pre-TAVI, 2.71±1.4 mm Hg·cm·s-1 versus post-TAVI 3.04±1.6 mm Hg·cm·s-1 [P=0.03]). Microvascular reserve over the wave-free period of diastole significantly improved post-TAVI (pre-TAVI 1.88±1.0 versus post-TAVI 2.09±0.8 [P=0.003]); this was independent of the severity of the underlying coronary stenosis. The change in microvascular resistance post-TAVI was equivalent to that produced by stenting a coronary lesion with an instantaneous wave-free ratio of ≤0.74. CONCLUSIONS: TAVI improves microcirculatory function regardless of the severity of underlying coronary disease. TAVI for severe AS produces a coronary hemodynamic improvement equivalent to the hemodynamic benefit of stenting coronary stenoses with instantaneous wave-free ratio values <0.74. Future trials of physiology-guided revascularization in severe AS may consider using this value to guide treatment of concomitant coronary artery disease.
  •  
3.
  • Byrne, Robert A., et al. (författare)
  • Report of a European Society of Cardiology-European Association of Percutaneous Cardiovascular Interventions task force on the evaluation of coronary stents in Europe : executive summary
  • 2015
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 36:38, s. 2608-2620
  • Tidskriftsartikel (refereegranskat)abstract
    • The evaluation for European Union market approval of coronary stents falls under the Medical Device Directive that was adopted in 1993. Specific requirements for the assessment of coronary stents are laid out in supplementary advisory documents. In response to a call by the European Commission to make recommendations for a revision of the advisory document on the evaluation of coronary stents (Appendix 1 of MEDDEV 2.7.1), the European Society of Cardiology (ESC) and the European Association of Percutaneous Cardiovascular Interventions (EAPCI) established a Task Force to develop an expert advisory report. As basis for its report, the ESC-EAPCI Task Force reviewed existing processes, established a comprehensive list of all coronary drug-eluting stents that have received a CE mark to date, and undertook a systematic review of the literature of all published randomized clinical trials evaluating clinical and angiographic outcomes of coronary artery stents between 2002 and 2013. Based on these data, the TF provided recommendations to inform a new regulatory process for coronary stents. The main recommendations of the task force include implementation of a standardized non-clinical assessment of stents and a novel clinical evaluation pathway for market approval. The two-stage clinical evaluation plan includes recommendation for an initial pre-market trial with objective performance criteria (OPC) benchmarking using invasive imaging follow-up leading to conditional CE-mark approval and a subsequent mandatory, large-scale randomized trial with clinical endpoint evaluation leading to unconditional CE-mark. The data analysis from the systematic review of the Task Force may provide a basis for determination of OPC for use in future studies. This paper represents an executive summary of the Task Force's report.
  •  
4.
  • Byrne, Robert A, et al. (författare)
  • Report of an ESC-EAPCI Task Force on the evaluation and use of bioresorbable scaffolds for percutaneous coronary intervention : executive summary
  • 2018
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 39:18, s. 1591-1601
  • Tidskriftsartikel (refereegranskat)abstract
    • A previous Task Force of the European Society of Cardiology (ESC) and European Association of Percutaneous Cardiovascular Interventions (EAPCI) provided a report on recommendations for the non-clinical and clinical evaluation of coronary stents. Following dialogue with the European Commission, the Task Force was asked to prepare an additional report on the class of devices known as bioresorbable scaffolds (BRS). Five BRS have CE-mark approval for use in Europe. Only one device-the Absorb bioresorbable vascular scaffold-has published randomized clinical trial data and this data show inferior outcomes to conventional drug-eluting stents (DES) at 2-3 years. For this reason, at present BRS should not be preferred to conventional DES in clinical practice. The Task Force recommends that new BRS devices should undergo systematic non-clinical testing according to standardized criteria prior to evaluation in clinical studies. A clinical evaluation plan should include data from a medium sized, randomized trial against DES powered for a surrogate end point of clinical efficacy. Manufacturers of successful devices receive CE-mark approval for use and must have an approved plan for a large-scale randomized clinical trial with planned long-term follow-up.
  •  
5.
  • Byrne, Robert A., et al. (författare)
  • Report of an ESC-EAPCI Task Force on the evaluation and use of bioresorbable scaffolds for percutaneous coronary intervention : executive summary
  • 2018
  • Ingår i: EuroIntervention. - : EUROPA EDITION. - 1774-024X .- 1969-6213. ; 13:13, s. 1574-1586
  • Tidskriftsartikel (refereegranskat)abstract
    • A previous Task Force of the European Society of Cardiology (ESC) and European Association of Percutaneous Cardiovascular Interventions (EAPCI) provided a report on recommendations for the non-clinical and clinical evaluation of coronary stents. Following dialogue with the European Commission, the Task Force was asked to prepare an additional report on the class of devices known as bioresorbable scaffolds (BRS). Five BRS have CE-mark approval for use in Europe. Only one device - the Absorb bioresorbable vascular scaffold - has published randomized clinical trial data and this data show inferior outcomes to conventional drug-eluting stents (DES) at 2-3 years. For this reason, at present BRS should not be preferred to conventional DES in clinical practice. The Task Force recommends that new BRS devices should undergo systematic non-clinical testing according to standardized criteria prior to evaluation in clinical studies. A clinical evaluation plan should include data from a medium sized, randomized trial against DES powered for a surrogate end point of clinical efficacy. Manufacturers of successful devices receive CE-mark approval for use and must have an approved plan for a large-scale randomized clinical trial with planned long-term follow-up.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy